Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position

被引:1
|
作者
Okamoto, Masanori [1 ]
Takegami, Yasuhiko [2 ]
Osawa, Yusuke [2 ]
Tanaka, Shinya [2 ]
Nobori, Tatsuya [1 ]
Imagama, Shiro [2 ]
机构
[1] Yokkaichi Municipal Hosp, Dept Orthopaed Surg, 11 2-2-37,Shibata, Yokaichi, Mie 5108567, Japan
[2] Nagoya Univ, Grad Sch Med, Dept Orthopaed Surg, 65 Tsurumai Cho,Showa Ku, Nagoya, 4668550, Japan
关键词
Hip; Total hip arthroplasty; Computer-assisted surgery; Portable navigation systems; Alignment guide; IMPROVE; THA; REGISTRATION; DYSPLASIA; OSTEOTOMY;
D O I
10.1007/s00402-024-05571-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) using a portable navigation system (PNS) incurs costs per procedure. However, it does not require a large console. This study aimed to compare the accuracy of acetabular cup placement using a pelvic alignment guide (PAG) attached to the pelvis and an accelerometer-based PNS in THA performed in the lateral decubitus position. Methods We retrospectively analyzed 100 hips that underwent primary THA in the lateral decubitus position between July 2018 and January 2021. The PAG was used in 50 hips, whereas the PNS was used in the other 50. Cup placement accuracy was measured using postoperative computed tomography scans, comparing errors in inclination and anteversion angles. The surgical time, blood loss, and complications were recorded. The follow-up period was at least 2 years in all cases. Results The mean absolute error of the inclination angle was similar between the groups (the PAG group: 3.7 degrees +/- 2.3 degrees [range, 0.0-9.0]; the PNS group: 3.7 degrees +/- 2.3 degrees [range, 0.2-10.5], p = 0.705). The mean absolute error of the anteversion angle was significantly smaller in the PAG group than in the PNS group (3.0 degrees +/- 2.4 degrees [range, 0.0-9.7] vs. 6.5 degrees +/- 4.8 degrees [range, 0.3-17.3], p < 0.001). The PAG group had a higher proportion of hips within 5 degrees and 10 degrees of the target angle (64 vs. 42%, P = 0.028, and 100 vs. 74%, p < 0.001, respectively). The PNS group had six hips with anteversion errors of 15 degrees or more. Surgical time and blood loss were lower in the PAG group. The PNS group had one dislocation, whereas the PAG group did not. Conclusion The accelerometer-based PNS did not demonstrate superior cup alignment accuracy compared to the PAG in THA performed in the lateral decubitus position. This finding informs surgeons that computer-assisted surgery is not necessarily superior to conventional THA using a PAG.
引用
收藏
页码:4849 / 4856
页数:8
相关论文
共 50 条
  • [21] Comparison of the accuracies of computed tomography-based navigation and image-free navigation for acetabular cup insertion in total hip arthroplasty in the lateral decubitus position
    Hasegawa, Masahiro
    Tone, Shine
    Naito, Yohei
    Wakabayashi, Hiroki
    Sudo, Akihiro
    COMPUTER ASSISTED SURGERY, 2021, 26 (01) : 69 - 76
  • [22] Comparison of the accuracy of CT- and accelerometer-based navigation systems for cup orientation in total hip arthroplasty
    Tetsunaga, Tomonori
    Yamada, Kazuki
    Tetsunaga, Tomoko
    Furumatsu, Takayuki
    Sanki, Tomoaki
    Kawamura, Yoshi
    Ozaki, Toshifumi
    HIP INTERNATIONAL, 2021, 31 (05) : 603 - 608
  • [23] Accuracy of Cup Placement Angle, Leg Lengthening, and Offset Measurement Using an AR-Based Portable Navigation System: Validation in Supine and Lateral Decubitus Positions for Total Hip Arthroplasty
    Ozaki, Yusuke
    Yamamoto, Takeaki
    Kimura, Satomi
    Kasai, Toru
    Niki, Rintaro
    Niki, Hisateru
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [24] Computed tomography-based navigation versus accelerometer-based portable navigation in total hip arthroplasty for dysplastic hip osteoarthritis
    Tanaka, Shinya
    Osawa, Yusuke
    Takegami, Yasuhiko
    Funahashi, Hiroto
    Ido, Hiroaki
    Asamoto, Takamune
    Imagama, Shiro
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2025, 35 (01)
  • [25] Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device
    Nakasone, Satoshi
    Takaesu, Mika
    Ishihara, Masato
    Onaga, Masamichi
    Igei, Takahiro
    Miyata, Yoshihide
    Nishida, Kotaro
    ARTHROPLASTY TODAY, 2022, 16 : 46 - 52
  • [26] Accuracy of acetabular cup placement using an angle-adjusting alignment guide with laser pointer in total hip arthroplasty
    Okanoue, Yusuke
    Aso, Koji
    Dan, Junpei
    Takaya, Shogo
    Izumi, Masashi
    Kawakami, Teruhiko
    Ikeuchi, Masahiko
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)
  • [27] The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system
    Yohei Naito
    Masahiro Hasegawa
    Shine Tone
    Hiroki Wakabayashi
    Akihiro Sudo
    BMC Musculoskeletal Disorders, 22
  • [28] The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [29] Is a portable accelerometer-based navigation system useful in total hip arthroplasty?: A systematic review and meta-analysis
    Shigemura, Tomonori
    Baba, Yoshihiko
    Murata, Yasuaki
    Yamamoto, Yohei
    Shiratani, Yuki
    Hamano, Hiroyuki
    Wada, Yuichi
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (01)
  • [30] Portable imageless navigation system and surgeon's estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position
    Takada, Ryohei
    Jinno, Tetsuya
    Miyatake, Kazumasa
    Hirao, Masanobu
    Yoshii, Toshitaka
    Okawa, Atsushi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (04) : 707 - 712