Valve-in-valve transcatheter mitral valve replacement versus redo-surgical mitral valve replacement for degenerated bioprosthetic mitral valves: A systematic review and meta-analysis

被引:2
作者
Nasir, Muhammad Moiz [1 ]
Amir, Suhaina [1 ]
Shahid, Ahmad [1 ]
Rehman, Wajeeh Ur [2 ]
Haris, Muhammad [1 ]
Ikram, Armeen [1 ]
Mubariz, Muhammad [3 ]
Ahmed, Jawad [1 ]
Khan, Ubaid [4 ]
Iqbal, Abdul Ghani [5 ]
Saeed, Hasham [6 ]
Noori, Muhammad Atif Masood [7 ]
机构
[1] Dow Univ Hlth Sci, Dept Internal Med, Karachi, Pakistan
[2] United Hlth Serv Hosp, Dept Internal Med, Johnson City, NY USA
[3] Akhtar Saeed Med & Dent Coll, Dept Internal Med, Lahore, Pakistan
[4] Univ Maryland, Sch Med, Div Cardiovasc Med, Baltimore, MD USA
[5] UNC Nash Gen Hosp, Dept Internal Med, Rocky Mount, NC USA
[6] RWJBarnabas Hlth, Trinitas Reg Med Ctr, Elizabeth, NJ USA
[7] St Josephs Univ, Med Ctr, Dept Cardiovasc Med, Paterson, NJ USA
关键词
Valve-in-valve transcatheter mitral valve replacement; Redo-surgical mitral valve relacement; Redo-SMVR; ViV-TMVR; Bioprosthetic mitral valve degeneration; Mitral valve; TRIAL DESIGN PRINCIPLES; END-POINT DEFINITIONS; CONSENSUS DOCUMENT; HEART-VALVES; IMPLANTATION; OUTCOMES; REPAIR; RISK;
D O I
10.1016/j.ijcard.2024.132448
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bioprosthetic mitral valve degeneration is traditionally treated with Redo-SMVR, but the latest ViV-TMVR procedure offers a less invasive and lower risk alternative. A systematic literature search was conducted on Cochrane Central, Scopus, and Medline (PubMed interface) electronic databases from inception till 15th April 2024. We used risk ratios (RR) for dichotomous outcomes and mean differences (MD) for continuous outcomes. We included a total of eleven studies with 11,931 patients in the final quantitative and qualitative analysis. When comparing ViV-TMVR with Redo-SMVR, no significant difference was found for 30-day mortality (P = 0.13) and 1-year mortality (P = 0.91), whereas patients in the ViV-TMVR showed significantly reduced incidence of stroke (P < 0.00001), In-hospital mortality (P), bleeding complications (P = 0.003), AKI (P = 0.0006), arrhythmias (P = 0.01), LVOT obstruction (P = 0.04), and PPI (P < 0.00001). Furthermore, no significant difference was observed between either group when comparing vascular complications (P = 0.97), 2-year mortality (P = 0.60) and 3-year mortality. ViV-TMVR was associated with a significant risk of paravalvular leakage (P = 0.008). Although, ViV-TMVR reduces the risk of complications associated with Redo-SMVR, larger studies are imperative to reach conclusive results.
引用
收藏
页数:9
相关论文
共 32 条
  • [1] [Anonymous], 2024, The PRISMA 2020 Statement: An Updated Guideline for Reporting Systematic Reviews
  • [2] [Anonymous], 2022, Cochrane Handbook for Systematic Reviews of Interventions
  • [3] [Anonymous], 2007, J. Bus. Tech. Commun., V21, P442
  • [4] Comparison of Outcomes After Transcatheter Versus Surgical Repeat Mitral Valve Replacement
    Arafat, Amr A.
    Zahra, Ashraf I.
    Alhossan, Abdulaziz
    Alghosoon, Haneen
    Alotaiby, Mohammad
    Albabtain, Monirah A.
    Adam, Adam I.
    Algarni, Khaled D.
    [J]. BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 38 (01) : 52 - 61
  • [5] Bapat Vinayak, 2014, EuroIntervention, V10 Suppl U, pU44, DOI 10.4244/EIJV10SUA7
  • [6] Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
  • [7] Incidence and pathophysiology of atrioventricular block following mitral valve replacement and ring annuloplasty
    Berdajs, Denis
    Schurr, Ulrich R.
    Wagner, Antonia
    Seifert, Burkhardt
    Turina, Marko I.
    Genoni, Michele
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (01) : 55 - 61
  • [8] Transfemoral Implantation of Transcatheter Heart Valves After Deterioration of Mitral Bioprosthesis or Previous Ring Annuloplasty
    Bouleti, Claire
    Fassa, Amir-Ali
    Himbert, Dominique
    Brochet, Eric
    Ducrocq, Gregory
    Nejjari, Mohammed
    Ghodbane, Walid
    Depoix, Jean-Pol
    Nataf, Patrick
    Vahanian, Alec
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (01) : 83 - 91
  • [9] 5-Year Experience With Transcatheter Transapical Mitral Valve-in-Valve Implantation for Bioprosthetic Valve Dysfunction
    Cheung, Anson
    Webb, John G.
    Barbanti, Marco
    Freeman, Melanie
    Binder, Ronald K.
    Thompson, Christopher
    Wood, David A.
    Ye, Jian
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (17) : 1759 - 1766
  • [10] Isolated Mitral Valve Surgery: The Society of Thoracic Surgeons Adult Cardiac Surgery Database Analysis
    Gammie, James S.
    Chikwe, Joanna
    Badhwar, Vinay
    Thibault, Dylan P.
    Vemulapalli, Sreekanth
    Thourani, Vinod H.
    Gillinov, Marc
    Adams, David H.
    Rankin, J. Scott
    Ghoreishi, Mehrdad
    Wang, Alice
    Ailawadi, Gorav
    Jacobs, Jeffrey P.
    Suri, Rakesh M.
    Bolling, Steven F.
    Foster, Nathaniel W.
    Quinn, Rachael W.
    [J]. ANNALS OF THORACIC SURGERY, 2018, 106 (03) : 716 - 727