A novel low-cost sensors system for real-time multipollutant indoor air quality monitoring - Development and performance

被引:0
作者
Chojer, H. [1 ,2 ]
Branco, P. T. B. S. [1 ,2 ]
Martins, F. G. [1 ,2 ]
Sousa, S. I. V. [1 ,2 ]
机构
[1] Univ Porto, Fac Engn, LEPABE Lab Proc Engn Environment Biotechnol & Ener, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
[2] Univ Porto, Fac Engn, ALiCE Associate Lab Chem Engn, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
关键词
Indoor air quality; Air quality monitoring; Calibration; Multipollutant; Low-cost sensors; FIELD CALIBRATION; AVAILABLE SENSORS; EXPOSURE; PLATFORM; CLUSTER; PART; HOME;
D O I
10.1016/j.buildenv.2024.112055
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air pollution poses a significant health risk, thus demanding effective indoor air quality (IAQ) monitoring strategies. Low-cost sensors (LCS) have gained attraction for IAQ monitoring, but their data accuracy and robustness remain key challenges. This study addresses gaps in the literature by developing and evaluating a novel low-cost monitor prototype for IAQ monitoring. A detailed design methodology based on requirements analysis was used to create two identical low-cost monitors (LCM) prototypes for multipollutant monitoring, including PM2.5, CO2, CO, O-3, NO2, temperature and relative humidity. The LCM were deployed in an in-field monitoring campaign alongside research-grade instruments. The uncorrected sensor signals showed linear response compared to research-grade instruments with high Pearson Correlation Coefficients for 1-min mean: PM2.5 (0.97), CO2 (0.81-0.89), CO (0.95-0.98), and O-3 (0.80-0.85). The concentration range of pollutants was observed to play a crucial role in the response and accuracy of the LCS. Kalman filter was implemented with optimised parameters to reduce noise from the signal of ozone sensors. Univariate and multivariate linear models were used to field calibrate the sensors. Linear regression models, with high coefficients of determination (>0.8) and low error values, imply that the developed LCM prototypes can be reliably used for indicative monitoring. In most of the cases, univariate linear models using only the sensor response of LCS as explanatory variables showed significant improvement. Future work will involve longer monitoring campaigns in different microenvironments, evaluation of calibration drift and to assess failure episodes in long-term use.
引用
收藏
页数:16
相关论文
共 61 条
  • [11] Source identification and mitigation of indoor air pollution using monitoring data - Current trends
    Chojer, H.
    Branco, P. T. B. S.
    Martins, F. G.
    Alvim-Ferraz, Mcm
    Sousa, S. I. V.
    [J]. ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2024, 33
  • [12] Can data reliability of low-cost sensor devices for indoor air particulate matter monitoring be improved?-An approach using machine learning
    Chojer, H.
    Branco, P. T. B. S.
    Martins, F. G.
    Alvim-Ferraz, M. C. M.
    Sousa, S. I. V.
    [J]. ATMOSPHERIC ENVIRONMENT, 2022, 286
  • [13] Development of low-cost indoor air quality monitoring devices: Recent advancements
    Chojer, H.
    Branco, P. T. B. S.
    Martins, F. G.
    Alvim-Ferraz, M. C. M.
    Sousa, S. I., V
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 727
  • [14] Chojer H., 2022, Intern. J. Environ. Impacts, V5, P7, DOI [10.2495/EIV5-N1-15-22, DOI 10.2495/EIV5-N1-15-22]
  • [15] Environmental Quality bOX (EQ-OX): A Portable Device Embedding Low-Cost Sensors Tailored for Comprehensive Indoor Environmental Quality Monitoring
    Corona, Jacopo
    Tondini, Stefano
    Gallichi Nottiani, Duccio
    Scilla, Riccardo
    Gambaro, Andrea
    Pasut, Wilmer
    Babich, Francesco
    Lollini, Roberto
    [J]. SENSORS, 2024, 24 (07)
  • [16] Performance of low-cost monitors to assess household air pollution
    Curto, A.
    Donaire-Gonzalez, D.
    Barrera-Gomez, J.
    Marshall, J. D.
    Nieuwenhuijsen, M. J.
    Wellenius, G. A.
    Tonne, C.
    [J]. ENVIRONMENTAL RESEARCH, 2018, 163 : 53 - 63
  • [17] Performance assessment of low-cost environmental monitors and single sensors under variable indoor air quality and thermal conditions
    Demanega, Ingrid
    Mujan, Igor
    Singer, Brett C.
    Andelkovic, Aleksandar S.
    Babich, Francesco
    Licina, Dusan
    [J]. BUILDING AND ENVIRONMENT, 2021, 187
  • [18] An In-Field Assessment of the P.ALP Device in Four Different Real Working Conditions: A Performance Evaluation in Particulate Matter Monitoring
    Fanti, Giacomo
    Borghi, Francesca
    Campagnolo, Davide
    Rovelli, Sabrina
    Carminati, Alessio
    Zellino, Carolina
    Cattaneo, Andrea
    Cauda, Emanuele
    Spinazze, Andrea
    Cavallo, Domenico Maria
    [J]. TOXICS, 2024, 12 (04)
  • [19] Gerboles M, 2009, EUR 23676 EN
  • [20] Development of an in-home, real-time air pollutant sensor platform and implications for community use
    Gillooly, Sara E.
    Zhou, Yulun
    Vallarino, Jose
    Chu, MyDzung T.
    Michanowicz, Drew R.
    Levy, Jonathan I.
    Adamkiewicz, Gary
    [J]. ENVIRONMENTAL POLLUTION, 2019, 244 : 440 - 450