Short-term primary and revision modular dual-mobility cup total hip arthroplasty outcomes in high-risk dislocation patients: a retrospective study

被引:0
作者
Ruusiala, Martta [2 ]
Miettinen, Hannu [1 ]
Kettunen, Jukka [1 ]
Kroeger, Heikki [1 ,2 ]
Miettinen, Simo [1 ,2 ]
机构
[1] Kuopio Univ Hosp, Dept Orthopaed Traumatol & Hand Surg, POB 1777, Kuopio 70211, Finland
[2] Univ Eastern Finland, Fac Hlth Sci, Yliopistonranta 1, Kuopio 70210, Finland
关键词
Total hip arthroplasty; Dual-mobility cup; Survival; Complications; Revision; FEMORAL-NECK FRACTURES; ACETABULAR COMPONENTS; REPLACEMENT; ASSOCIATION; THA;
D O I
10.1007/s00590-024-04092-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeModular dual-mobility cups (MDMCs) have a lower risk for dislocation after total hip arthroplasty (THA). The primary aims of our study were to analyze implant survivorship and to determine complications, especially dislocation, and revision rates of primary THAs used for hip fracture patients and for revision THAs. Secondary aims were to evaluate mortality after MDMC surgery and to find out if introduction of MDMC at our institution (Kuopio University Hospital, Finland) have decreased dislocation rate.MethodsThis retrospective cohort study consisted of 101 MDMC patients who were consecutively operated at our institution between April 1, 2018 and June 30, 2020. The implant survival rate, complications and mortality were evaluated with minimum of 2-year follow-up. Finnish Hospital Discharge Register was used to find out yearly dislocation rates following THA at our institution.ResultsThe cumulative estimate implant survival after MDMC in the primary THA group was 97% at 2 years, and in the revision THA group, it was 90% at 2 years. Dislocation was a rare complication in the primary THA group (1.4%), while it was common in revision THA group (12.9%). The cumulative estimate for mortality after MDMC in the primary THA group was 13% at 2 years, and in the revision group, it was also 13% at 2 years. The yearly number of patients who had re-hospitalization period due to THA dislocation decreased 46% after implementation of MDMC.ConclusionShort-term survival and complication rates after MDMC were excellent after primary THA and moderate after revision THA. Implementation of MDMC THA for hip fracture patients seems to have effectively decrease dislocation rate during a short follow-up.
引用
收藏
页码:3981 / 3988
页数:8
相关论文
共 50 条
[31]   Dual-Mobility Constructs in Primary and Revision Total Hip Arthroplasty: A Systematic Review of Comparative Studies [J].
Reina, Nicolas ;
Pareek, Ayoosh ;
Krych, Aaron J. ;
Pagnano, Mark W. ;
Berry, Daniel J. ;
Abdel, Matthew P. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (03) :594-603
[32]   Dual Mobility Cups in Revision Total Hip Arthroplasty: Efficient Strategy to Decrease Dislocation Risk [J].
Schmidt, Axel ;
Batailler, Cecile ;
Fary, Camdon ;
Servien, Elvire ;
Lustig, Sebastien .
JOURNAL OF ARTHROPLASTY, 2020, 35 (02) :500-507
[33]   In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis [J].
Yasuhiro Homma ;
Tomonori Baba ;
Yu Ozaki ;
Taiji Watari ;
Hideo Kobayashi ;
Hironori Ochi ;
Mikio Matsumoto ;
Kazuo Kaneko .
International Orthopaedics, 2017, 41 :491-497
[34]   Double mobility cup total hip arthroplasty in patients at high risk for dislocation: a single-center analysis [J].
Dominik Kaiser ;
Atul F. Kamath ;
Patrick Zingg ;
Claudio Dora .
Archives of Orthopaedic and Trauma Surgery, 2015, 135 :1755-1762
[35]   Dual-mobility tripod cup for revision hip arthroplasty: long-term (five to fourteen years) evaluation of a new generation cementless implant [J].
Klein, Aurelien ;
Bordes, Maxence ;
Viste, Anthony ;
Fessy, Michel .
INTERNATIONAL ORTHOPAEDICS, 2024, 48 (05) :1241-1247
[36]   The Avantage ® dual mobility cup in primary total hip arthroplasty: A registry study [J].
Castiello, E. ;
Bruschi, A. ;
Bordini, B. ;
De Gaetano, F. ;
Tigani, D. .
JOURNAL OF ORTHOPAEDICS, 2024, 56 :98-102
[37]   Risk factors for dislocation after revision total hip arthroplasty with a dual-mobility cup. Matched case-control study (16 cases vs. 48 controls) [J].
Huten, Denis ;
Fournier, Yohann ;
Gicquel, Thomas ;
Bertho, Pierre ;
Basselot, Frederic ;
Hamadouche, Moussa .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (07) :1303-1309
[38]   Early results of total hip arthroplasty using dual-mobility cup in patients with osteonecrosis of the femoral head [J].
Assi, Chahine ;
Kheir, Nadim ;
Samaha, Camille ;
Kouyoumjian, Pascal ;
Yammine, Kaissar .
SICOT-J, 2018, 4
[39]   Dual-mobility cups in total hip arthroplasty after femoral neck fractures: A retrospective study comparing outcomes between cemented and cementless fixation [J].
Uriarte, Iker ;
Moreta, Jesus ;
Jimenez, Inigo ;
Legarreta, Maria Jose ;
Mozos, Jose Luis Martinez de los .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (06) :1467-1472
[40]   Malseating of Modular Dual Mobility Liners: High Prevalence in Revision Total Hip Arthroplasty [J].
Bengoa, Francisco J. ;
Howard, Lisa C. ;
Neufeld, Michael E. ;
Garbuz, Donald S. .
JOURNAL OF ARTHROPLASTY, 2023, 38 (07) :S211-S216