Ruthenium complex based nanocomposite film with enhanced and selective electrochemical sensing of bifenthrin pesticide

被引:0
作者
Bhandari, Sanjeev [1 ]
Sen, Bhaskar [2 ]
Khatua, Snehadrinarayan [2 ]
Singh, L. Robindro [3 ]
Parihar, Vijay Singh [4 ]
Mahato, Mrityunjoy [1 ]
机构
[1] North Eastern Hill Univ, Sch Technol, Dept Basic Sci & Social Sci, Phys Div, Shillong 793022, Meghalaya, India
[2] North Eastern Hill Univ, Ctr Adv Studies, Dept Chem, Shillong 793022, Meghalaya, India
[3] North Eastern Hill Univ, Sch Technol, Dept Nanotechnol, Shillong 793022, Meghalaya, India
[4] Tampere Univ, Fac Med & Hlth Technol, Biomat & Tissue Engn Grp, Tampere 33720, Finland
基金
芬兰科学院;
关键词
LANGMUIR-BLODGETT-FILMS; POLYPYRIDINE COMPLEXES; CARBON NANOTUBES; SENSOR; NANOPARTICLES; GROWTH; FABRICATION; MONOLAYER; POLYMERS; PROBE;
D O I
10.1039/d4ra04188g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Bifenthrin (BF), a widely used pyrethroid pesticide in farming, lacks highly sensitive and selective sensors despite its extensive application. Ruthenium complexes are very effective for selective sensing applications but suffer from structural instability at elevated conditions, electrochemical activity, and the use of costly electrolytes. This work improves their electrochemical activity and mechanical strength by incorporating silver nanowires and replacing the costly electrolyte with abundant KCl + PBS, resulting in enhanced signal performance. Herein, a ruthenium complex containing composite film was immobilized on a platinum (Pt) electrode using Langmuir Blodgett technique. The fabricated sensor has been characterized by differential pulse voltammetry (DPV) based electrochemical technique. The BF pesticide sensing parameters, including the limit of detection (LOD), linear range (LR), and sensitivity, were evaluated using SWV, DPV, and CV techniques. Among these, the DPV technique demonstrated the best performance, achieving a sensitivity of 0.648 mu A cm-2 mu M-1, a LR of 1-10 mu M, and a LOD of 1 mu M. The relative standard deviation (RSD) values using DPV are found to be 6.3% (repeatability study), 3% (reproducibility study), 8% (metal ion interference), 5% (organic species interference), and 2% (real sample study), which are much lesser than the World Health Organization (WHO) recommendation of RSD value on the pesticide (i.e. 20%). The BF sensor demonstrated a selectivity of 2x difference of peak height response compared to similar pesticides. The reported pesticide sensor will open new options for sensor research using metal complex-based LB film nanocomposite. Bifenthrin (BF), a widely used pyrethroid pesticide in farming, lacks highly sensitive and selective sensors despite its extensive application.
引用
收藏
页码:29542 / 29558
页数:17
相关论文
共 112 条
[1]   Structure and Elastic Properties of an Unsymmetrical Bi-Heterocyclic Azo Compound in the Langmuir Monolayer and Langmuir-Blodgett Film [J].
Ahmed, Ikbal ;
Mathur, Tanmay ;
Islam, A. K. M. Maidul ;
Plaisier, Jasper R. ;
Parisse, Pietro ;
Thomas, Sabu ;
Bal, Jayanta Kumar .
ACS OMEGA, 2020, 5 (34) :21538-21549
[2]   Chitosan-fatty acid interaction mediated growth of Langmuir monolayer and Langmuir-Blodgett films [J].
Ahmed, Ikbal ;
Dildar, Lucky ;
Haque, Anamul ;
Patra, Prasun ;
Mukhopadhyay, Mala ;
Hazra, Satyajit ;
Kulkarni, Manish ;
Thomas, Sabu ;
Plaisier, Jasper R. ;
Dutta, Shyamal Baran ;
Bal, Jayanta Kumar .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2018, 514 :433-442
[3]   FT-IR Spectroscopy for the Identification of Binding Sites and Measurements of the Binding Interactions of Important Metal Ions with Bovine Serum Albumin [J].
Alhazmi, Hassan A. .
SCIENTIA PHARMACEUTICA, 2019, 87 (01)
[4]   4,7-Dimethoxy-1,10-phenanthroline:: An excellent ligand for the Cu-catalyzed N-arylation of imidazoles [J].
Altman, Ryan A. ;
Buchwald, Stephen L. .
ORGANIC LETTERS, 2006, 8 (13) :2779-2782
[5]   Citrate-capped silver nanoparticles as a probe for sensitive and selective colorimetric and spectrophotometric sensing of creatinine in human urine [J].
Alula, Melisew Tadele ;
Karamchand, Leshern ;
Hendricks, Nicolette R. ;
Blackburn, Jonathan M. .
ANALYTICA CHIMICA ACTA, 2018, 1007 :40-49
[6]  
[Anonymous], 2022, Annual Report
[7]   Development of highly sensitive polysilicon nanogap with APTES/GOx based lab-on-chip biosensor to determine low levels of salivary glucose [J].
Balakrishnan, Sharma Rao ;
Hashim, U. ;
Letchumanan, G. R. ;
Kashif, M. ;
Ruslinda, A. R. ;
Liu, W. W. ;
Veeradasan, P. ;
Prasad, R. Haarindra ;
Foo, K. L. ;
Poopalan, P. .
SENSORS AND ACTUATORS A-PHYSICAL, 2014, 220 :101-111
[8]   Compression/expansion rheology of oil/water interfaces with adsorbed proteins. Comparison with the air/water surface [J].
Benjamins, J. ;
Lyklema, J. ;
Lucassen-Reynders, E. H. .
LANGMUIR, 2006, 22 (14) :6181-6188
[9]  
Bhandari S., 2022, Int. J. Environ. Anal. Chem, V104, P1
[10]   A Biosensor Based on Polyaniline-Carbon Nanotube Core-Shell for Electrochemical Detection of Pesticides [J].
Cesarino, Ivana ;
Moraes, Fernando C. ;
Machado, Sergio A. S. .
ELECTROANALYSIS, 2011, 23 (11) :2586-2593