Consistency of sex-based differences between treadmill and overground running using an inertial measurement unit (IMU)

被引:0
|
作者
Miqueleiz, Unai [1 ,2 ]
Aguado-Jimenez, Roberto [1 ]
Lecumberri, Pablo [3 ]
Gorostiaga, Esteban M. [2 ]
机构
[1] Univ Publ Navarra, Dept Hlth Sci, Pamplona, Spain
[2] Govt Navarre, Studies Res & Sports Med Ctr CEIMD, Pamplona, Spain
[3] Univ Publ Navarra, Dept Math, Pamplona, Spain
关键词
Biomechanics; Treadmill Running; Overground Running; Sex; Accelerometer; GROUND REACTION FORCES; GENDER-DIFFERENCES; PLANTAR PRESSURE; KINEMATICS; HIP; VARIABILITY; STRENGTH; JOINT;
D O I
10.1016/j.jbiomech.2024.112202
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Differences in running gait between treadmill and overground running has been subject of study, while consistency of group differences between running surfaces has not been previously analysed. This study examined both the differences between running surfaces and the consistency of sex-based differences between surfaces in some spatiotemporal and kinematic variables measured by an inertial measurement unit fastened over the lumbar spine. Thirty-two (sixteen females) endurance runners firstly performed overground and then treadmill (1 % inclination) runs at speeds between 9-21 km center dot h- 1. Males showed lower flight time (FT) [moderate effect size (ES)] during treadmill running compared to overground, while females showed greater stride frequency (SF) (moderate ES), lower stride length (SL) (moderate ES), FT (moderate ES), and vertical (VT) trunk displacement (moderate ES), as well as greater medio-lateral (ML) trunk displacement (moderate ES). No differences in CT between surfaces were found (trivial to small). Furthermore, all the sex-differences were consistent between treadmill and overground running: Males showed lower SF (large and moderate ES, respectively), greater SL (large and moderate ES) and CT (moderate and large ES), lower FT (large ES), greater VT displacement (moderate to large ES), and lower ML displacement (moderate ES) than females. These results may be of interest to carefully transfer the running gait analyses between surfaces depending on sex.
引用
收藏
页数:7
相关论文
共 43 条
  • [31] A PC-Based Orientation Sensing using 9-DOF Strapdown Inertial Measurement Unit
    Hun, Lim Chot
    Sze, Lim Tien
    Chet, Koo Voon
    2012 12TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS & VISION (ICARCV), 2012, : 229 - 234
  • [32] Sex-based differences in association between circulating T cell subsets and disease activity in untreated early rheumatoid arthritis patients
    Aldridge, Jonathan
    Pandya, Jayesh M.
    Meurs, Linda
    Andersson, Kerstin
    Nordstrom, Inger
    Theander, Elke
    Lundell, Anna-Carin
    Rudin, Anna
    ARTHRITIS RESEARCH & THERAPY, 2018, 20
  • [33] Low-pass filter cutoff frequency affects sacral-mounted inertial measurement unit estimations of peak vertical ground reaction force and contact time during treadmill running
    Day, Evan M.
    Alcantara, Ryan S.
    McGeehan, Michael A.
    Grabowski, Alena M.
    Hahn, Michael E.
    JOURNAL OF BIOMECHANICS, 2021, 119
  • [34] Racket orientation angle differences between accurate and inaccurate squash shots, as determined by a racket embedded magnetic-inertial measurement unit
    Williams, Benjamin K.
    Sanders, Ross H.
    Ryu, Joong Hyun
    Graham-Smith, Philip
    Sinclair, Peter J.
    SPORTS BIOMECHANICS, 2024, 23 (06) : 817 - 829
  • [35] Differences in kinematic parameters during gait between the patients with knee osteoarthritis and healthy controls using an insole with a single inertial measurement unit: A case-control study
    Yaguchi, Haruki
    Honda, Keita
    Sekiguchi, Yusuke
    Huang, Chenhui
    Fukushi, Kenichiro
    Wang, Zhenwei
    Nakahara, Kentaro
    Kamimura, Masayuki
    Aki, Takashi
    Ogura, Ken
    Izumi, Shin- Ichi
    CLINICAL BIOMECHANICS, 2024, 112
  • [36] Strain and sex-based glucocentric & behavioral differences between KK/HlJ and C57BL/6J mice
    Inglis, Angela
    Shibin, Sherin
    Ubungen, Rosario
    Farooq, Sarah
    Mata, Princess
    Thiam, Jennifer
    Al-Mohanna, Futwan A.
    Collison, Kate S.
    PHYSIOLOGY & BEHAVIOR, 2019, 210
  • [37] Quantitative analysis of the bilateral coordination and gait asymmetry using inertial measurement unit-based gait analysis
    Han, Seung Hwan
    Kim, Chang Oh
    Kim, Kwang Joon
    Jeon, Jeanhong
    Chang, Hsienhao
    Kim, Eun Seo
    Park, Hoon
    PLOS ONE, 2019, 14 (10):
  • [38] Sex-based differences in track running distances of 100, 200, 400, 800, and 1500m in the 8 and under and 9-10-year-old age groups
    Brown, Gregory A.
    Shaw, Brandon S.
    Shaw, Ina
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2024, 24 (02) : 217 - 225
  • [39] Drift-Free 3D Orientation and Displacement Estimation for Quasi-Cyclical Movements Using One Inertial Measurement Unit: Application to Running
    Zandbergen, Marit A.
    Reenalda, Jasper
    van Middelaar, Robbert P.
    Ferla, Romano I.
    Buurke, Jaap H.
    Veltink, Peter H.
    SENSORS, 2022, 22 (03)
  • [40] Differences between Systems Using Optical and Capacitive Sensors in Treadmill-Based Spatiotemporal Analysis of Level and Sloping Gait
    Mandalidis, Dimitris
    Kafetzakis, Ioannis
    SENSORS, 2022, 22 (07)