Effect of channel depth ratio and absorber plate configuration on performance of a solar air heater

被引:2
|
作者
Patel, Vijay [1 ]
Judal, K. B. [2 ]
Sharma, Kamal [3 ]
Rosen, Marc A. [4 ]
Kumar, Abhinav [5 ]
Mumtaz, Mohd Aamir [6 ]
Elgamal, Mohamed H. [6 ]
Farouk, Mohamed I. [6 ]
Malik, Ishfaq [7 ]
机构
[1] Govt Engn Coll Palanpur, Dept Mech Engn, Palanpur, Gujarat, India
[2] Govt Engn Coll Dahod, Dept Mech Engn, Dahod, Gujarat, India
[3] GLA Univ, Mech Engn Dept, Mathura, India
[4] Univ Ontario Inst Technol, Fac Engn & Appl Sci, 2000 Simcoe St North, Oshawa, ON L1G 0C5, Canada
[5] Ural Fed Univ, Dept Nucl & Renewable Energy, Ekaterinburg 620002, Russia
[6] Imam Mohammad Ibn Saud Islamic Univ, Coll Engn, Civil Engn Dept, Riyadh 11432, Saudi Arabia
[7] Debre Birhan Univ, Dept Econ, Debre Birhan, Ethiopia
关键词
Solar air heater; Channel depth ratio; Phase change material; Absorber plate; THERMAL PERFORMANCE; COLLECTOR; ENERGY; DRYER; STORAGE; EXERGY;
D O I
10.1016/j.csite.2024.104789
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental evaluation of the effect of channel depth ratio and absorber plate configuration on the performance of a baffled counter flow double-pass solar air heater (BCDSAH) is main objective of current work. The BCDSAH was constructed so as to permit adjustments of channel depth ratio (CDR) to 2, 3 and 4. During experimentation, the lower channel depth was kept at 50 mm while the upper channel depth was adjusted to 100 mm, 150 mm and 200 mm, yielding various channel depth ratios. The assessments were conducted for three configurations of absorber plate: (i) flat absorber plate, (ii) baffled absorber plate and (iii) baffled absorber plate with phase change material (PCM). The performance of the BCDSAH was evaluated at an air mass flow rate of 0.07 kg/s for temperature rise, useful heat gain (UHG), energy efficiency, and exergy efficiency. For CDR = 2 and a baffled absorber plate with PCM, the obtained average values of temperature rise, UHG, energy efficiency and exergy efficiency were 15.3 degrees C, 1075.2 W, 76.2 % and 2.7 % respectively. For the baffled absorber plate with PCM, increases of 8.5 %, 9.4 %, 10.1 % and 10.9 % were obtained in temperature rise, UHG, energy efficiency and exergy efficiency respectively for CDR = 2 compared to CDR = 4. Finally, a value of CDR = 2 and a baffled absorber plate with PCM are suitable for applications like drying of agricultural products and space heating.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Thermal Performance of Double Pass Solar Air Heater With Tubular Solar Absorber
    Hussein, Nassr Fadhil
    Ahmed, Sabah T.
    Ekaid, Ali L.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2023, 12 (01): : 11 - 21
  • [42] Numerical Analysis of Flat Plate Solar Air Heater Integrated With an Array of Pin Fins on Absorber Plate for Enhancement in Thermal Performance
    Manjunath, M. S.
    Karanth, K. Vasudeva
    Sharma, N. Yagnesh
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (05):
  • [43] Performance analysis of parallel flow flat plate solar air heater having arc shaped wire roughened absorber plate
    Yadav, Kapil Dev
    Prasad, Radha Krishna
    RENEWABLE ENERGY FOCUS, 2020, 32 : 23 - 44
  • [44] Performance analysis of parallel flow flat plate solar air heater having arc shaped wire roughened absorber plate
    Yadav, Kapil Dev
    Prasad, Radha Krishna
    Renewable Energy Focus, 2020, 32 : 23 - 44
  • [45] Influence of pitch and height of pentagonal ribbed absorber plate of solar air heater for performance enhancement with environmental analysis
    Sheelam, Shekher
    Chandramohan, V. P.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 56
  • [46] Thermal and thermohydraulic performance of wavy finned absorber solar air heater
    Priyam, Abhishek
    Chand, Prabha
    SOLAR ENERGY, 2016, 130 : 250 - 259
  • [47] EXPERIMENTAL PERFORMANCE OF A SOLAR AIR HEATER WITH A V-CORRUGATED ABSORBER
    JOUDI, KA
    MOHAMMED, AI
    ENERGY CONVERSION AND MANAGEMENT, 1986, 26 (02) : 193 - 200
  • [48] Performance enhancement of a double-pass solar air heater with a shot-blasted absorber plate and winglets
    P. Ganesh Kumar
    D. Sakthivadivel
    K. Balaji
    Mohammed Salman
    Sung Chul Kim
    Journal of Mechanical Science and Technology, 2021, 35 : 2743 - 2753
  • [49] Exergy based performance evaluation of solar air heater with arc-shaped wire roughened absorber plate
    Sahu, Mukesh Kumar
    Prasad, Radha Krishna
    RENEWABLE ENERGY, 2016, 96 : 233 - 243
  • [50] Thermo-hydraulic performance of a solar air heater with staggered C-shape finned absorber plate
    Saravanan, A.
    Murugan, M.
    Reddy, M. Sreenivasa
    Ranjit, P. S.
    Elumalai, P., V
    Kumar, Pramod
    Sree, S. Rama
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 168