Effect of channel depth ratio and absorber plate configuration on performance of a solar air heater

被引:2
|
作者
Patel, Vijay [1 ]
Judal, K. B. [2 ]
Sharma, Kamal [3 ]
Rosen, Marc A. [4 ]
Kumar, Abhinav [5 ]
Mumtaz, Mohd Aamir [6 ]
Elgamal, Mohamed H. [6 ]
Farouk, Mohamed I. [6 ]
Malik, Ishfaq [7 ]
机构
[1] Govt Engn Coll Palanpur, Dept Mech Engn, Palanpur, Gujarat, India
[2] Govt Engn Coll Dahod, Dept Mech Engn, Dahod, Gujarat, India
[3] GLA Univ, Mech Engn Dept, Mathura, India
[4] Univ Ontario Inst Technol, Fac Engn & Appl Sci, 2000 Simcoe St North, Oshawa, ON L1G 0C5, Canada
[5] Ural Fed Univ, Dept Nucl & Renewable Energy, Ekaterinburg 620002, Russia
[6] Imam Mohammad Ibn Saud Islamic Univ, Coll Engn, Civil Engn Dept, Riyadh 11432, Saudi Arabia
[7] Debre Birhan Univ, Dept Econ, Debre Birhan, Ethiopia
关键词
Solar air heater; Channel depth ratio; Phase change material; Absorber plate; THERMAL PERFORMANCE; COLLECTOR; ENERGY; DRYER; STORAGE; EXERGY;
D O I
10.1016/j.csite.2024.104789
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental evaluation of the effect of channel depth ratio and absorber plate configuration on the performance of a baffled counter flow double-pass solar air heater (BCDSAH) is main objective of current work. The BCDSAH was constructed so as to permit adjustments of channel depth ratio (CDR) to 2, 3 and 4. During experimentation, the lower channel depth was kept at 50 mm while the upper channel depth was adjusted to 100 mm, 150 mm and 200 mm, yielding various channel depth ratios. The assessments were conducted for three configurations of absorber plate: (i) flat absorber plate, (ii) baffled absorber plate and (iii) baffled absorber plate with phase change material (PCM). The performance of the BCDSAH was evaluated at an air mass flow rate of 0.07 kg/s for temperature rise, useful heat gain (UHG), energy efficiency, and exergy efficiency. For CDR = 2 and a baffled absorber plate with PCM, the obtained average values of temperature rise, UHG, energy efficiency and exergy efficiency were 15.3 degrees C, 1075.2 W, 76.2 % and 2.7 % respectively. For the baffled absorber plate with PCM, increases of 8.5 %, 9.4 %, 10.1 % and 10.9 % were obtained in temperature rise, UHG, energy efficiency and exergy efficiency respectively for CDR = 2 compared to CDR = 4. Finally, a value of CDR = 2 and a baffled absorber plate with PCM are suitable for applications like drying of agricultural products and space heating.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Effect of geometrical aspects on the performance of jet plate solar air heater
    Nayak, R. K.
    Singh, S. N.
    SOLAR ENERGY, 2016, 137 : 434 - 440
  • [22] Augmenting the Thermal Performance of Solar Air Heater with Absorber Plate Roughened with Pin-Fins
    Khelkar, Ashish B.
    Syrti, Kynjrilang
    Das, Rajat Subhra
    Sarkar, Bikash Kumar
    2022 7TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND ROBOTICS RESEARCH, ICMERR, 2022, : 179 - 185
  • [23] Experimental investigation of a solar air heater with copper wool on the absorber plate
    Bicer, Ayse
    Devecioglu, Atilla G.
    Oruc, Vedat
    Tuncer, Zafer
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2020, 17 (15) : 979 - 989
  • [24] Numerical analysis of a solar air heater with circular perforated absorber plate
    Shetty, Shreyas P.
    Madhwesh, N.
    Karanth, K. Vasudeva
    SOLAR ENERGY, 2021, 215 : 416 - 433
  • [25] Effect of duct length variation on solar air heater performance for smooth and D-shaped roughened absorber plate
    Dutt, Nitesh
    Hedau, Ankush
    Kumar, Ashwani
    Awasthi, Mukesh Kumar
    Singh, Varun Pratap
    HEAT TRANSFER, 2024, 53 (07) : 3902 - 3930
  • [26] PERFORMANCE OF A 2-CHANNEL SUSPENDED FLAT-PLATE SOLAR AIR HEATER
    DHIMAN, NK
    TIWARI, GN
    ENERGY CONVERSION AND MANAGEMENT, 1984, 24 (04) : 269 - 275
  • [27] Thermal performance of wavy finned absorber solar air heater
    Priyam, Abhishek
    Chand, Prabha
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2018, 36 (04) : 1393 - 1403
  • [28] Fully developed periodic and thermal performance evaluation of a solar air heater channel with wavy-triangular ribs placed on an absorber plate
    Promthaisong, P.
    Eiamsa-ard, S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 140 : 413 - 428
  • [29] Performance evaluation of solar air heater having expanded metal mesh as artificial roughness on absorber plate
    Gupta, M. K.
    Kaushik, S. C.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (05) : 1007 - 1016
  • [30] Performance evaluation of solar air heater having V-down perforated baffles on the absorber plate
    Chamoli, Sunil
    Thakur, N. S.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (06)