Analysis of infrared radiation emitted by moxibustion devices made of different materials using Fourier transform infrared spectroscopy

被引:0
|
作者
Zhang, Jiachen [1 ]
He, Jing [1 ]
Shuang, Shuang [2 ]
Shi, Yuqing [1 ]
Han, Li [3 ]
Hui, Xin [4 ]
Ouyang, Xiali [1 ]
Zhu, Jingyi [1 ]
Wang, Zhongyu [3 ]
Zhao, Baixiao [1 ]
He, Rui [5 ]
机构
[1] Beijing Univ Chinese Med, Sch Acupuncture Moxibust & Tuina, Beijing, Peoples R China
[2] Natl Inst Clean & Low Carbon Energy, Beijing, Peoples R China
[3] Beijing Univ Chinese Med, Sch Tradit Chinese Med, Beijing, Peoples R China
[4] Beijing Aerosp Gen Hosp, Beijing, Peoples R China
[5] Beijing Univ Chinese Med, Sch Life Sci, Beijing, Peoples R China
关键词
Traditional Chinese medicine; Integrative medicine; Moxibustion; Fourier transform infrared spectroscopy; Combustion stability; Infrared radiation intensity; Principal component analysis;
D O I
10.1016/j.heliyon.2024.e33221
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Moxibustion has a long history of use as a traditional Chinese medicine therapy. Infrared radiation is an important and effective factor in moxibustion. Instead of the time-consuming and laborious process of holding moxa sticks in the hand, moxibustion devices are commonly used as moxibustion methods and tools in modern times. With the publication of the international standard of moxibustion devices (ISO18666:2021, Traditional Chinese Medicine - General requirements of moxibustion devices) published, moxibustion devices of various materials are now sold in the pharmacies and online stores. However, the influence of moxibustion devices on the therapeutic effect of moxibustion has not been studied. Therefore, this research was aimed to evaluate the infrared radiation of moxibustion devices, in order to select the moxibustion device that delivered infrared radiation closest to that of moxa stick combustion. The combination of combustion stability and infrared radiation intensity showed that cardboard tubes and silicone were better materials for moxibustion devices. In the mid-far infrared wave band, the moxibustion devices made from cardboard tubes and silica gels can better maintain the thermal effect generated by moxibustion and enable it to be more easily absorbed by the human body. The infrared radiation intensity of the cardboard moxibustion devices increased rapidly and steadily and could be maintained for the longest time. In conclusion, cardboard tubes are the better material for moxibustion devices with respect to infrared radiation.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Characterization of different compost extracts using Fourier-transform infrared spectroscopy (FTIR) and thermal analysis
    Teresa Carballo
    Ma Victoria Gil
    Xiomar Gómez
    Fernando González-Andrés
    Antonio Morán
    Biodegradation, 2008, 19 : 815 - 830
  • [32] Online Analysis Method of Cement Raw Materials Based on Fourier Transform Infrared Spectroscopy
    Hu Rong
    Liu Wen-ging
    Xu Liang
    Jin Ling
    Yang Wei-feng
    Wang Yu-hao
    Hu Kai
    Liu Jian-guo
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (01) : 41 - 47
  • [33] ANALYSIS OF PHOTOOXIDATION OF POLYMER MATERIALS BY PHOTOACOUSTIC FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    DELPRAT, P
    GARDETTE, JL
    POLYMER, 1993, 34 (05) : 933 - 937
  • [34] Accelerated climate aging of building materials and their characterization by Fourier transform infrared radiation analysis
    Jelle, Bjorn Petter
    Nilsen, Tom-Nils
    Hovde, Per Jostein
    Gustavsen, Arild
    JOURNAL OF BUILDING PHYSICS, 2012, 36 (01) : 99 - 112
  • [35] Spectroscopic analysis of bladder cancer tissues using Fourier transform infrared spectroscopy
    Nafie A. Al-Muslet
    Essam E. Ali
    Journal of Applied Spectroscopy, 2012, 79 : 139 - 142
  • [36] Analysis of temporomandibular joint synovial fluid using Fourier transform/infrared spectroscopy
    Ziegler, CM
    Kircher, P
    Hassfeld, S
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (11) : 1302 - 1306
  • [37] Gallstone analysis using Fourier transform infrared spectroscopy (FT-IR)
    Yoo, Eun-Hyung
    Oh, Hyeon-Ju
    Lee, Soo-Youn
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (03) : 376 - 381
  • [38] Analysis of lard in meatball broth using Fourier transform infrared spectroscopy and chemometrics
    Kurniawati, Endah
    Rohman, Abdul
    Triyana, Kuwat
    MEAT SCIENCE, 2014, 96 (01) : 94 - 98
  • [39] SPECTROSCOPIC ANALYSIS OF BLADDER CANCER TISSUES USING FOURIER TRANSFORM INFRARED SPECTROSCOPY
    Al-Muslet, Nafie A.
    Ali, Essam E.
    JOURNAL OF APPLIED SPECTROSCOPY, 2012, 79 (01) : 139 - 142
  • [40] Cool spectroscopy using high resolution Fourier transform infrared spectroscopy
    Sams, RL
    Blake, TA
    Sharpe, SW
    FOURIER TRANSFORM SPECTROSCOPY, TECHNICAL DIGEST, 2001, 51 : 154 - 156