Enhancing the Seismic Performances of Concrete Filled Steel Box Columns by Improving Confinement Effect: A Numerical Approach

被引:0
|
作者
Alahakoon, A. M. Y. D. [1 ]
Malalage, V. P. [1 ]
Pigera, A. C. D. [1 ]
Jayasinghe, J. A. S. C. [1 ]
机构
[1] Univ Peradeniya, Fac Engn, Dept Civil Engn, Peradeniya, Sri Lanka
来源
ENGINEER-JOURNAL OF THE INSTITUTION OF ENGINEERS SRI LANKA | 2024年 / 57卷 / 03期
关键词
Concrete-filled steel tube; Confinement effect; Cyclic loading; Finite element model; Seismic performance; BRIDGE PIERS; CYCLIC BEHAVIOR; DUCTILITY; MODEL;
D O I
10.4038/engineer.v57i3.7658
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Highway piers are essential in elevated roadways, and they are widely used in industrialized nations. Therefore, designing piers that can withstand severe seismic loadings is critical, especially in regions where earthquakes are common. Because of their remarkable seismic resilience, concrete-filled steel tubular (CFST) columns have become more popular. Numerous investigations have been carried out to enhance the seismic performance of CFST columns. The goal of this study is to alter the stiffener arrangements of concrete-filled steel box columns in order to increase their strength, ductility, energy absorption capacity and hence enhance their overall performance by enhancing the confinement effect. A comprehensive finite element model of CFST column with stiffeners was developed and validated using past experimental data. By adopting the same modelling procedure, ten models of CFST columns with modified cross sections by changing the stiffener length, stiffener arrangement and flange to web ratio of stiffeners were numerically tested under lateral cyclic loads with constant axial loads to understand the effective cross section for the confinement effect. Results revealed that the T arrangement of stiffeners shows an increment in confinement effect which results in enhancement of lateral performance of the column. Further enhancement of the confinement was obtained by changing the flange to web ratio (L-f/L-w) of the stiffeners. Finally, the obtained force- displacement curves were compared to investigate the effect of confinement and it was revealed that the cross-section having the ratio of L-f/L-w = 2.0 performs better than the other cross-sectional arrangements in strength and for the energy absorption capacity, while L-f/L-w = 1.0 is the best arrangement for the ductility.
引用
收藏
页码:95 / 106
页数:12
相关论文
共 50 条
  • [31] Behaviour of concrete-filled steel columns under the seismic loading
    Shimizu, S.
    Watanabe, T.
    THIN-WALLED STRUCTURES, 2007, 45 (10-11) : 921 - 926
  • [32] Seismic Performance of Recycled Concrete Filled Circular Steel Tube Columns
    Xu, Dingyi
    Chen, Zongping
    Zhou, Chunheng
    FRONTIERS IN MATERIALS, 2020, 7 (07):
  • [33] Prediction of axial capacity of octagonal concrete-filled steel tube columns considering confinement effect
    Abbas, Nazar J.
    Ali, Ammar A.
    INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2022, 12 (02) : 170 - 188
  • [34] Experimental Research on The Confinement Effect for the Composite Concrete-Filled Square Steel Tubular Short Columns
    Li, Bin
    Gao, Chunyan
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 2118 - 2123
  • [35] CONCRETE-FILLED STEEL TUBULAR COLUMNS WITH INTERNAL CONFINEMENT BY HIGH STRENGTH STEEL SPIRALS
    Teng, J. G.
    Zhang, J.
    Wang, J. J.
    Lin, G.
    Feng, P.
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [36] Weak confinement effect of concrete-filled thin-walled steel box short column
    Wang, Huan
    Kang, Ling
    Chen, Ming
    Zou, Qi
    Mu, Tingmin
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2024, 56 (11): : 162 - 170
  • [37] DUCTILITY OF CONCRETE-FILLED STEEL BOX COLUMNS UNDER CYCLIC LOADING
    USAMI, T
    GE, HB
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (07): : 2021 - 2040
  • [38] Cyclic analysis and capacity prediction of concrete-filled steel box columns
    Susantha, KAS
    Ge, HB
    Usami, T
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2002, 31 (02): : 195 - 216
  • [39] Time effects in concrete-filled steel box columns in tall buildings
    Uy, B
    Das, S
    STRUCTURAL DESIGN OF TALL BUILDINGS, 1997, 6 (01): : 1 - 22
  • [40] Behaviour and design of high strength steel-concrete filled box columns
    Uy, B