Axial Compressive Behavior of CFRP and MWCNT Incorporated GFRP Confined Concrete Cylinders after Exposure to Various Aggressive Environments

被引:0
作者
Kavitha, Sruthi Sreekumar [1 ,2 ]
Madhavan, Mini K. [3 ]
Jayanarayanan, Karingamanna [1 ,2 ]
Sarker, Prabir Kumar [4 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Chem Engn & Mat Sci, Coimbatore 641112, India
[2] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Ctr Excellence Adv Mat & Green Technol CoE AMGT, Coimbatore 641112, India
[3] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Civil Engn, Coimbatore 641112, India
[4] Curtin Univ, Sch Civil & Mech Engn, Civil Engn Discipline, Perth, WA 6102, Australia
关键词
fiber-reinforced polymer; MWCNT; epoxy; confinement; axial compressive behavior; acid exposure; elevated temperature; MECHANICAL-PROPERTIES; FUNCTIONALIZED MWCNT; DAMAGE ASSESSMENT; CARBON NANOTUBES; HYBRID FRP; FIBER; PERFORMANCE; DURABILITY; STRENGTH; SYSTEM;
D O I
10.3390/jcs8080313
中图分类号
TB33 [复合材料];
学科分类号
摘要
Fiber-reinforced polymer confinement is considered to be effective in the retrofitting of concrete structures. The current study explores the effectiveness of one- and two-layer carbon fiber reinforced polymer (CFRP) and multiwalled carbon nanotube (MWCNT) incorporated three-layer glass fiber reinforced polymer (GFRP) confinement on concrete cylinders under aggressive exposures, such as acid, alkaline, marine, water, and elevated temperatures. At 1 wt.% MWCNT by weight of the epoxy matrix, mechanical characteristics of the laminate show a significant improvement. In the case of acid exposure, the axial load-carrying capacity of concrete specimens with single-layer CFRP confinement was equal to that of MWCNT incorporated three-layer GFRP confinement (GF3C1-AC). The axial strain of GF3C1-AC was 23% and 12% higher than one and two-layer CFRP confinement. After exposure at 400 degrees C, in comparison with one- and two-layer CFRP confinement, the axial strain of MWCNT incorporated three-layer GFRP confined specimens increased by 50% and 20%, respectively, which proved the efficacy of MWCNT as a heat-resistant nanofiller. The ultrasonic pulse velocity (UPV) test indicates that the confinement system protects the concrete core from sudden failure by impeding crack propagation. The test results proved that the MWCNT incorporated FRP system can be considered as a prospective substitute for CFRP systems for retrofitting applications in severe environmental conditions.
引用
收藏
页数:20
相关论文
共 62 条
[41]   Effect of surface functionalization on mechanical properties and decomposition kinetics of high performance polyetherimide/MWCNT nano composites [J].
Pitchan, Mohan Kumar ;
Bhowmik, Shantanu ;
Balachandran, Meera ;
Abraham, M. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2016, 90 :147-160
[42]   Comparative behavior under compression of concrete columns repaired by fiber reinforced polymer (FRP) jacketing and ultra high-performance fiber reinforced concrete (UHPFRC) [J].
Rabehi, B. ;
Ghernouti, Y. ;
Li, Alex ;
Boumchedda, K. .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2014, 28 (22-23) :2327-2346
[43]   Mechanical property evaluation of sisal-jute-glass fiber reinforced polyester composites [J].
Ramesh, M. ;
Palanikumar, K. ;
Reddy, K. Hemachandra .
COMPOSITES PART B-ENGINEERING, 2013, 48 :1-9
[44]   Experimental and micromechanical modeling of fracture toughness: MWCNT-reinforced polypropylene/glass fiber hybrid composites [J].
Rasana, Nanoth ;
Jayanarayanan, Karingamanna .
JOURNAL OF THERMOPLASTIC COMPOSITE MATERIALS, 2019, 32 (08) :1031-1055
[45]   Inherent seismic resilience of RC columns externally confined with nonbonded composite ropes [J].
Rousakis, Theodoros C. .
COMPOSITES PART B-ENGINEERING, 2018, 135 :142-148
[46]   Effects of carbon nanotube enrichment of epoxy resins on hybrid FRP-FR confinement of concrete [J].
Rousakis, Theodoros C. ;
Kouravelou, Katerina B. ;
Karachalios, Theodoros K. .
COMPOSITES PART B-ENGINEERING, 2014, 57 :210-218
[47]   Synergistic effect of carbon fabric and multiwalled carbon nanotubes on the fracture, wear and dynamic load response of epoxy-based multiscale composites [J].
Sarath Kumar, P. ;
Jayanarayanan, Karingamanna ;
Deeraj, B. D. S. ;
Joseph, K. ;
Balachandran, Meera .
POLYMER BULLETIN, 2022, 79 (07) :5063-5084
[48]   Detection of interface flaws in Concrete-FRP composite structures using linear and nonlinear ultrasonics based techniques [J].
Sasmal, Saptarshi ;
Basu, Sukanya ;
Himakar, Chunduri V. V. ;
Kundu, Tribikram .
ULTRASONICS, 2023, 132
[49]  
Sen Tara, 2015, International Journal of Sustainable Built Environment, V4, P248, DOI [10.1016/j.ijsbe.2015.04.001, 10.1016/j.ijsbe.2015.04.001]
[50]   Behavior and Effectiveness of FRP Wrap in the Confinement of Large Concrete Cylinders [J].
Smith, Scott T. ;
Kim, Seo Jin ;
Zhang, Huawen .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) :573-582