Radiation safety of ultra-high dose rate electron accelerators for FLASH radiotherapy

被引:4
作者
Praestegaard, Lars Hjorth [1 ]
机构
[1] Aarhus Univ Hosp, Dept Oncol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
关键词
bremsstrahlung; electron accelerator; FLASH effect; induced activity; neutrons; radiation safety; radiation shielding; radiotherapy; ultra-high dose rate (UHDR);
D O I
10.1002/mp.17245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAn ultra-high dose rate (UHDR) electron accelerator for FLASH radiotherapy (RT) produces very intense bremsstrahlung by the interaction of the electron beam with objects both inside and outside of the accelerator. The bremsstrahlung dose per pulse is typically 1-2 orders of magnitude larger than that of conventional RT x-ray treatment of the same energy, and for electron energies above 10 MeV, the bremsstrahlung produces substantially more induced radioactivity outside the accelerator than for conventional RT. Therefore, a thorough radiation safety assessment is mandatory prior to the operation of a UHDR electron accelerator.PurposeTo evaluate the radiation safety of a prototype FLASH-enabled Varian TrueBeam accelerator and to develop a general framework for assessment of all key radiation safety properties of a UHDR electron accelerator for FLASH RT.MethodsProduction of bremsstrahlung and induced radioactivity by a UHDR electron accelerator is modeled by various analytical methods. The analytical modeling is compared with National Institute of Standards and Technology (NIST) bremsstrahlung yield data as well as measurements of primary bremsstrahlung outside the bunker and induced radioactivity of irradiated thick targets for a FLASH-enabled 16 MeV Varian TrueBeam electron accelerator. In addition, the analytical modeling is complemented by measurements of secondary bremsstrahlung inside/outside the bunker and neutrons at the maze entrance.ResultsCalculated bremsstrahlung yields deviate maximum 8.5% from NIST data, and all measurements of primary bremsstrahlung and induced radioactivity agree with calculations, validating the analytical tools. In addition, it is found that scattering foil bremsstrahlung dominates primary bremsstrahlung and the main source of secondary bremsstrahlung is the irradiated object outside the accelerator. It follows that primary and secondary bremsstrahlung outside the bunker can be calculated using the same simple formalism as that used for conventional RT. Measured primary bremsstrahlung tenth-value layers for concrete of the simple formalism are in good agreement with NCRP and IAEA data, while measured secondary bremsstrahlung tenth-value layers for concrete are considerably lower than NCRP and IAEA data. All calculations and measurements form a general framework for assessment of all key radiation safety properties of a UHDR electron accelerator.ConclusionsThe FLASH-enabled Varian TrueBeam accelerator is safe for normal operation (max. 99 pulses per irradiation) in a bunker designed for at least 15 MV conventional x-ray treatment unless the UHDR workload is much larger than the x-ray workload. A similar finding applies to other UHDR electron accelerators. However, during beam tuning, radiation survey, or other tests with extended irradiation time, the UHDR workload may become very large, necessitating the implementation of additional safety measures.
引用
收藏
页码:6206 / 6219
页数:14
相关论文
共 28 条
  • [21] Petoussi-Henss N., 2010, Annals of the ICRP, V40
  • [22] Radiation shielding and safety implications following linac conversion to an electron FLASH-RT unit
    Poirier, Yannick
    Mossahebi, Sina
    Becker, Stewart J.
    Koger, Brandon
    Xu, Junliang
    Lamichhane, Narrotam
    Maxim, Peter G.
    Sawant, Amit
    [J]. MEDICAL PHYSICS, 2021, 48 (09) : 5396 - 5405
  • [23] Water equivalent phantom materials for 192Ir brachytherapy
    Schoenfeld, Andreas A.
    Harder, Dietrich
    Poppe, Bjoern
    Chofor, Ndimofor
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (24) : 9403 - 9420
  • [24] BREMSSTRAHLUNG ENERGY-SPECTRA FROM ELECTRONS WITH KINETIC-ENERGY 1 KEV-10 GEV INCIDENT ON SCREENED NUCLEI AND ORBITAL ELECTRONS OF NEUTRAL ATOMS WITH Z = 1-100
    SELTZER, SM
    BERGER, MJ
    [J]. ATOMIC DATA AND NUCLEAR DATA TABLES, 1986, 35 (03) : 345 - 418
  • [25] Pencil beam scanning proton FLASH maintains tumor control while normal tissue damage is reduced in a mouse model
    Sorensen, Brita Singers
    Sitarz, Mateusz Krzysztof
    Ankjaergaard, Christina
    Johansen, Jacob G.
    Andersen, Claus E.
    Kanouta, Eleni
    Grau, Cai
    Poulsen, Per
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 175 : 178 - 184
  • [26] Union E., 2013, COUNCIL DIRECTIVE 20
  • [27] The Advantage of FLASH Radiotherapy Confirmed in Mini-pig and Cat-cancer Patients
    Vozenin, Marie-Catherine
    De Fornel, Pauline
    Petersson, Kristoffer
    Favaudon, Vincent
    Jaccard, Maud
    Germond, Jean-Francois
    Petit, Benoit
    Burki, Marco
    Ferrand, Gisele
    Patin, David
    Bouchaab, Hanan
    Ozsahin, Mahmut
    Bochud, Francois
    Bailat, Claude
    Devauchelle, Patrick
    Bourhis, Jean
    [J]. CLINICAL CANCER RESEARCH, 2019, 25 (01) : 35 - 42
  • [28] XRay Mass Attenuation Coefficients, NATL I STANDARDS TEC