The role of implant projection in optimizing transcatheter aortic valve implantation

被引:0
作者
alvarez-Velasco, Rut [1 ,2 ]
Almendarez, Marcel [1 ,2 ]
Alperi, Alberto [1 ,2 ]
Antuna, Paula [1 ,2 ]
del Valle, Raquel [1 ,2 ]
Moris, Cesar [1 ,2 ,3 ]
Pascual, Isaac [1 ,2 ,3 ]
机构
[1] Hosp Univ Cent Asturias, Area Corazon, Oviedo, Asturias, Spain
[2] Inst Invest Sanitaria Principado Asturias, Oviedo, Asturias, Spain
[3] Univ Oviedo, Fac Med, Oviedo, Asturias, Spain
来源
REC-INTERVENTIONAL CARDIOLOGY | 2024年
关键词
Cusp overlap projection. Commissural alignment. Transcatheter aortic valve replacement; CUSP-OVERLAP TECHNIQUE; CONDUCTION DISTURBANCES; TAVR; REPLACEMENT; ALIGNMENT; IMPACT;
D O I
10.24875/RECICE.M24000473
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Severe aortic stenosis is the most frequent valve condition requiring surgery, and its incidence is increasing yearly. Transcatheter aortic valve implantation (TAVI) is the first-line treatment for patients at all levels of surgical risk. Nevertheless, modifications to the procedure often appear to improve clinical outcomes. A major concern after TAVI is the higher rate of permanent pacemaker implantation (PPMI) compared with surgical valve replacement. Optimal implantation depth is crucial to reduce the burden of PPMI without causing serious complications such as valve embolization. The classic implantation technique, where the 3 cusps are aligned in the same plane, has been modified to a cusp overlap projection by isolating the noncoronary cusp and superimposing the left and right cusps. This simple modification provides optimal visualization during deployment and helps to achieve the desired implant depth to reduce conduction disturbances and PPMI. Another limitation after TAVI is coronary reaccess due to the frame of the transcatheter valve obstructing the coronary ostia. Commissural alignment of the prostheses with the native valve may facilitate selective cannulation of the coronary arteries after this procedure. This review will discuss the techniques and supporting evidence for these modifications to the deployment and implant projection methods, and how they can improve TAVI outcomes.
引用
收藏
页数:8
相关论文
共 49 条
[1]   Cusp-overlap technique during TAVI using the self-expanding Portico FlexNav system [J].
Asmarats, Lluis ;
Gutierrez-Alonso, Lola ;
Nombela-Franco, Luis ;
Regueiro, Ander ;
Millan, Xavier ;
Tirado-Conte, Gabriela ;
Cepas, Pedro ;
Li, Chi Hion Pedro ;
Fernandez-Peregrina, Estefania ;
Jimenez-Quevedo, Pilar ;
Freixa, Xavier ;
Arzamendi, Dabit .
REVISTA ESPANOLA DE CARDIOLOGIA, 2023, 76 (10) :767-773
[2]   Clinical impact of the extent of jeopardized myocardium in patients undergoing transcatheter aortic valve intervention [J].
Aurigemma, Cristina ;
Giannico, Maria Benedetta ;
Burzotta, Francesco ;
Romagnoli, Enrico ;
Cangemi, Stefano ;
Bianchini, Francesco ;
Bruno, Piergiorgio ;
Leone, Antonio Maria ;
Gaspardone, Achille ;
Crea, Filippo ;
Trani, Carlo .
REVISTA ESPANOLA DE CARDIOLOGIA, 2023, 76 (03) :157-164
[3]  
Barbanti Marco, 2022, Rev Esp Cardiol (Engl Ed), V75, P194, DOI 10.1016/j.rec.2021.08.013
[4]   Coronary Cannulation After Transcatheter Aortic Valve Replacement The RE-ACCESS Study [J].
Barbanti, Marco ;
Costa, Giuliano ;
Picci, Andrea ;
Criscione, Enrico ;
Reddavid, Claudia ;
Valvo, Roberto ;
Todaro, Denise ;
Deste, Wanda ;
Condorelli, Antonio ;
Scalia, Matteo ;
Licciardello, Alessandra ;
Politi, Giorgia ;
De Luca, Giuseppe ;
Strazzieri, Orazio ;
Motta, Silvia ;
Garretto, Valeria ;
Veroux, Pierfrancesco ;
Giaquinta, Alessia ;
Giuffrida, Angelo ;
Sgroi, Carmelo ;
Leon, Martin B. ;
Webb, John G. ;
Tamburino, Corrado .
JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (21) :2542-2555
[5]   Double S-Curve Versus Cusp-Overlap Technique Defining the Optimal Fluoroscopic Projection for TAVR With a Self-Expanding Device [J].
Ben-Shoshan, Jeremy ;
Alosaimi, Hind ;
Lauzier, Pascal Theriault ;
Pighi, Michele ;
Talmor-Barkan, Yeela ;
Overtchouk, Pavel ;
Martucci, Giuseppe ;
Spaziano, Marco ;
Finkelstein, Ariel ;
Gada, Hemal ;
Piazza, Nicolo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) :185-194
[6]   Implantation depth and its influence on complications after TAVI with self-expanding valves [J].
Breitbart, Philipp ;
Minners, Jan ;
Hein, Manuel ;
Schroefel, Holger ;
Neumann, Franz-Josef ;
Ruile, Philipp .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (10) :3081-3092
[7]   A computed tomography study of coronary access and coronary obstruction after redo transcatheter aortic valve implantation [J].
Buzzatti, Nicola ;
Montorfano, Matteo ;
Romano, Vittorio ;
De Backer, Ole ;
Soendergaard, Lars ;
Rosseel, Liesbeth ;
Maurovich-Horvat, Pal ;
Karady, Julia ;
Merkely, Bela ;
Prendergast, Bernard D. ;
De Bonis, Michele ;
Colombo, Antonio ;
Latib, Azeem .
EUROINTERVENTION, 2020, 16 (12) :E1005-+
[8]   Large-scale community echocardiographic screening reveals a major burden of undiagnosed valvular heart disease in older people: the OxVALVE Population Cohort Study [J].
d'Arcy, Joanna L. ;
Coffey, Sean ;
Loudon, Margaret A. ;
Kennedy, Andrew ;
Pearson-Stuttard, Jonathan ;
Birks, Jacqueline ;
Frangou, Eleni ;
Farmer, Andrew J. ;
Mant, David ;
Wilson, Jo ;
Myerson, Saul G. ;
Prendergast, Bernard D. .
EUROPEAN HEART JOURNAL, 2016, 37 (47) :3515-+
[9]  
Ferrer-Sistach E, 2023, REV ESP CARDIOL, V76, P40, DOI [10.1016/j.recesp.2022.05.023, 10.1016/j.rec.2022.06.007]
[10]   Spanish cardiac catheterization and coronary intervention registry. 31st official report of the Interventional Cardiology Association of the Spanish Society of Cardiology (1990-2021) [J].
Freixa, Xavier ;
Jurado-Roman, Alfonso ;
Cid, Belen ;
Cruz-Gonzalez, Ignacio .
REVISTA ESPANOLA DE CARDIOLOGIA, 2022, 75 (12) :1040-1049