X-ray spectrometry for calculating conversion coefficients from air kerma to operational quantities in radiation protection

被引:0
|
作者
Plagnard, Johann [1 ]
Lefevre, Jeremie [1 ]
机构
[1] CEA, LIST, Lab Natl Henri Becquerel LNE LNHB, F-91191 Gif Sur Yvette, France
关键词
x-ray spectrometry; radiation protection; operational quantities; conversion coefficients; dosimetry; spectral correction algorithms; PERSONAL DOSE-EQUIVALENT; PHOTONS;
D O I
10.1088/1361-6498/ad6777
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study explores the conversion coefficients from air kerma to operational quantities for radiation protection, using x-ray spectrometry for the narrow-beam qualities below 300 keV as defined by ISO 4037-1. By employing custom spectral correction algorithms combined with modern cadmium telluride (CdTe) semiconductor detectors, we effectively corrected spectral distortions caused by detection processes, ensuring more reliable measurements. These measurements are crucial for meeting radiation protection standards. The study also analyses the sources of uncertainty associated with the determination of conversion coefficients, thereby providing improved accuracy and reproducibility in photon dosimetry.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields
    Kelaranta, Anna
    Ekholm, Marja
    Toroi, Paula
    Kortesniemi, Mika
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (01)
  • [32] Analysis of human teeth and bones from the chalcolithic period by X-ray spectrometry
    Carvalho, ML
    Casaca, C
    Pinheiro, T
    Marques, JP
    Chevallier, P
    Cunha, AS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 168 (04) : 559 - 565
  • [33] Effect of the Mexico City's air density in low-energy X-ray spectra and its influence in the air kerma and absorbed depth-dose to water
    Moreno-Ramirez, A.
    Massillon-Jl, G.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (09):
  • [34] Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures
    Golikov, Vladislav
    Druzhinina, Polina
    MEDICAL PHYSICS, 2020, 47 (10) : 5366 - 5372
  • [35] The Effect of Stepping Back From the X-Ray Table on Operator Radiation Exposure
    Wilson, Robert F.
    Gainor, John P.
    Allen, Blair
    HEALTH PHYSICS, 2021, 121 (05): : 522 - 530
  • [36] Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures
    Golikov, Vladislav
    Druzhinina, Polina
    MEDICAL PHYSICS, 2020, : 5366 - 5372
  • [37] Enhancing X-ray radiation protection with novel liquid silicone rubber composites: A promising alternative to lead aprons
    Abdullah, Wesam
    Ramli, Ramzun M.
    Khazaalah, Thair Hussein
    Azman, Nurul Zahirah Noor
    Nawafleh, Tasnim M.
    Salem, Farah
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (09) : 3608 - 3615
  • [38] Effectiveness of additional X-ray protection devices in reducing scattered radiation in radial intervention: the ESPRESSO randomised trial
    Anadol, Remzi
    Brandt, Moritz
    Merz, Nico
    Knorr, Maike
    Ahoopai, Majid
    Geyer, Martin
    Krompiec, Damian
    Wenzel, Phillip
    Munzel, Thomas
    Gori, Tommaso
    EUROINTERVENTION, 2020, 16 (08) : 663 - +
  • [39] Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
    Haeusler, Uwe
    Czarwinski, Renate
    Brix, Gunnar
    EUROPEAN RADIOLOGY, 2009, 19 (08) : 2000 - 2008
  • [40] X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room
    Dresing, K.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2011, 23 (01): : 70 - +