X-ray spectrometry for calculating conversion coefficients from air kerma to operational quantities in radiation protection

被引:0
|
作者
Plagnard, Johann [1 ]
Lefevre, Jeremie [1 ]
机构
[1] CEA, LIST, Lab Natl Henri Becquerel LNE LNHB, F-91191 Gif Sur Yvette, France
关键词
x-ray spectrometry; radiation protection; operational quantities; conversion coefficients; dosimetry; spectral correction algorithms; PERSONAL DOSE-EQUIVALENT; PHOTONS;
D O I
10.1088/1361-6498/ad6777
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study explores the conversion coefficients from air kerma to operational quantities for radiation protection, using x-ray spectrometry for the narrow-beam qualities below 300 keV as defined by ISO 4037-1. By employing custom spectral correction algorithms combined with modern cadmium telluride (CdTe) semiconductor detectors, we effectively corrected spectral distortions caused by detection processes, ensuring more reliable measurements. These measurements are crucial for meeting radiation protection standards. The study also analyses the sources of uncertainty associated with the determination of conversion coefficients, thereby providing improved accuracy and reproducibility in photon dosimetry.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography
    Kharrati, H
    MEDICAL PHYSICS, 2005, 32 (05) : 1367 - 1374
  • [2] Measurement of conversion coefficients between free in air kerma and personal dose equivalent for diagnostic X-ray beams
    Rosado, P. H. G.
    Nogueira, M. S.
    Genezini, F.
    Vilela, E. C.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 968 - 971
  • [3] Conversion coefficients from absorbed dose to tissue to the newly proposed ICRU/ICRP operational quantities for radiation protection for beta reference radiation qualities
    Behrens, Rolf
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : 871 - 901
  • [4] Computation of conversion coefficients relating air Kerma to Hp(0.07,α), Hp(10,α), and H*(10) for x-ray narrow spectrum from 40 to 140 kV
    Kharrati, H
    Zarrad, B
    MEDICAL PHYSICS, 2004, 31 (02) : 277 - 284
  • [5] AIR KERMA TO HP(3) CONVERSION COEFFICIENTS FOR EXPOSURE OF THE HUMAN EYE LENS TO THE SELECTED STANDARD X-RAY BEAM QUALITIES
    Krstic, Dragana
    Jovanovic, Zoran
    Nikezic, Dragoslav
    Ciraj-Bjelac, Olivera
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 231 - 234
  • [6] Conversion coefficients from air kerma to personal dose equivalent in mammography
    Kunzel, R.
    Levenhagen, R. S.
    Herdade, S. B.
    RADIATION PHYSICS AND CHEMISTRY, 2010, 79 (05) : 594 - 596
  • [7] DETERMINATION OF CALIBRATION X-RAY BEAM QUALITIES AND ESTABLISH A SET OF CONVERSION COEFFICIENTS FOR CALIBRATION OF RADIATION PROTECTION DEVICES USED IN DIAGNOSTIC RADIOLOGY
    Siddiqua, Tanjim
    Rahman, Md Shakilur
    Sanaullah, Md
    Mitu, Zohora Akter
    Hossain, Imran
    Rubai, Sadeka Sultana
    EAST EUROPEAN JOURNAL OF PHYSICS, 2021, (03): : 55 - 61
  • [8] Evaluation of conversion coefficients relating air-kerma to H☆(10) using primary and transmitted x-ray spectra in the diagnostic radiology energy range
    Santos, J. C.
    Mariano, L.
    Tomal, A.
    Costa, P. R.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (01) : 117 - 132
  • [9] Radiation Protection of X-Ray Rooms
    E. G. Chikirdin
    Biomedical Engineering, 2001, 35 (2) : 60 - 64
  • [10] Establishment of 350-450kV wide spectrum and high air-kerma rate X-ray radiation mass
    Wang, Bo
    Wu, Jinjie
    Du, Haiyan
    Guo, Siming
    Ren, Shiwei
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (23): : 8824 - 8828