Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis

被引:0
|
作者
Masuda, Takanori [1 ]
Nakaura, Takeshi [2 ]
Higaki, Toru [3 ]
Funama, Yoshinori [4 ]
Matsumoto, Yoriaki [3 ]
Sato, Tomoyasu [5 ]
Okimoto, Tomokazu [6 ]
Arao, Keiko [1 ]
Imaizumi, Hiromasa [1 ]
Arao, Shinichi [1 ]
Ono, Atsushi [1 ]
Hiratsuka, Junichi [1 ]
Awai, Kazuo [3 ]
机构
[1] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Hiroshima Univ, Grad Sch Biomed Sci, Dept Diagnost Radiol, Hiroshima, Japan
[4] Kumamoto Univ, Fac Life Sci, Dept Med Phys, Kumamoto, Japan
[5] Tsuchiya Gen Hosp, Dept Diagnost Radiol, Naka Ku, Hiroshima, Japan
[6] Edogawa Hosp, Dept Cardiovasc Internal Med, Tokyo, Japan
关键词
contrast enhancement optimizer simulation software; transcatheter aortic valve implantation; computed tomography angiography; contrast material; contrast enhancement; TAVI - Transcatheter aortic valve implantation; AS - aortic stenosis; CTA - contrast tomography angiography; CM - contrast materials; HU - Hounsfield units; p-COP - optimizer simulation software; CT - computed tomography; CO - cardiac output; BW - body weight; CT; VOLUME; WEIGHT; TAVI;
D O I
10.1097/RCT.0000000000001603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis. Methods: We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups. Results: Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection (P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B (P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively (P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71). Conclusion: The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.
引用
收藏
页码:759 / 762
页数:4
相关论文
共 50 条
  • [21] Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    Maksymilian P. Opolski
    Won-Keun Kim
    Christoph Liebetrau
    Claudia Walther
    Johannes Blumenstein
    Luise Gaede
    Jörg Kempfert
    Arnaud Van Linden
    Thomas Walther
    Christian W. Hamm
    Helge Möllmann
    Clinical Research in Cardiology, 2015, 104 : 471 - 480
  • [22] Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation
    Peter Bernhardt
    Christoph Rodewald
    Julia Seeger
    Birgid Gonska
    Dominik Buckert
    Michael Radermacher
    Vinzenz Hombach
    Wolfgang Rottbauer
    Jochen Wöhrle
    Clinical Research in Cardiology, 2016, 105 : 273 - 278
  • [23] Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation
    Bernhardt, Peter
    Rodewald, Christoph
    Seeger, Julia
    Gonska, Birgid
    Buckert, Dominik
    Radermacher, Michael
    Hombach, Vinzenz
    Rottbauer, Wolfgang
    Woehrle, Jochen
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (03) : 273 - 278
  • [24] Distribution of Aortic Annulus Dimensions in Patients Referred for Cardiac Computed Tomography Prior to Transcatheter Aortic Valve Implantation
    Johannes, Rixe
    Schuhbaeck, Annika
    Rolf, Andreas
    Nef, Holger
    Moellmann, Helge
    Liebetrau, Christoph
    Szardien, Sebastian
    Doerr, Oliver
    Erkapic, Damir
    Hamm, Christian W.
    Achenbach, Stephan
    CIRCULATION, 2012, 126 (21)
  • [25] Utility of Radio logic Review for Noncardiac Findings on Multislice Computed Tomography in Patients With Severe Aortic Stenosis Evaluated for Transcatheter Aortic Valve Implantation
    Ben-Dor, Itsik
    Waksman, Ron
    Hanna, Nicholas N.
    Raizon, Arnold
    Satler, Lowell F.
    Torguson, Rebecca
    Weissman, Gaby
    Okubagzi, Petros
    Xue, Zhenyi
    Li, Yanlin
    Gonzalez, Manuel A.
    Maluenda, Gabriel
    Gaglia, Michael A., Jr.
    Wakabayashi, Kohei
    Delhaye, Cedric
    Syed, Asmir I.
    Collins, Sara D.
    Suddath, William O.
    Kent, Kenneth M.
    Lindsay, Joseph
    Pichard, Augusto D.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (10) : 1461 - 1464
  • [26] Computed tomography guided tailored approach to transfemoral access in patients undergoing transcatheter aortic valve implantation
    Wiewiorka, Lukasz
    Trebacz, Jaroslaw
    Sobczynski, Robert
    Stapor, Maciej
    Ostrowska-Kaim, Elzbieta
    Konstanty-Kalandyk, Janusz
    Musial, Robert
    Gackowski, Andrzej
    Malinowski, Krzysztof
    Kleczynski, Pawel
    Zmudka, Krzysztof
    Kapelak, Boguslaw
    Legutko, Jacek
    CARDIOLOGY JOURNAL, 2023, 30 (01) : 51 - 58
  • [27] Incidental findings on computed tomography for preoperative assessment before transcatheter aortic valve implantation in Japanese patients
    Akihiro Tobe
    Akihito Tanaka
    Yoshiyuki Tokuda
    Yusuke Miki
    Kenji Furusawa
    Sho Akita
    Taro Fujii
    Yoshinori Tsutsumi
    Hideki Ishii
    Shingo Iwano
    Shinji Naganawa
    Akihiko Usui
    Toyoaki Murohara
    Heart and Vessels, 2021, 36 : 1911 - 1922
  • [28] Incidental findings on computed tomography for preoperative assessment before transcatheter aortic valve implantation in Japanese patients
    Tobe, Akihiro
    Tanaka, Akihito
    Tokuda, Yoshiyuki
    Miki, Yusuke
    Furusawa, Kenji
    Akita, Sho
    Fujii, Taro
    Tsutsumi, Yoshinori
    Ishii, Hideki
    Iwano, Shingo
    Naganawa, Shinji
    Usui, Akihiko
    Murohara, Toyoaki
    HEART AND VESSELS, 2021, 36 (12) : 1911 - 1922
  • [29] Evaluating the Impacts of Procedural and Patient-Specific Factors on the Outcomes of Transcatheter Aortic Valve Implantation (TAVI)
    Kurmanaliyev, Abilkhair
    Braukyliene, Rima
    Aldujeli, Ali
    Zhumagaliyev, Rassul
    Aitaliyev, Serik
    Unikas, Ramunas
    MEDICINA-LITHUANIA, 2025, 61 (01):
  • [30] The cardiac computed tomography-derived extracellular volume fraction predicts patient outcomes and left ventricular mass reductions after transcatheter aortic valve implantation for aortic stenosis
    Ishiyama, Masaki
    Kurita, Tairo
    Takafuji, Masafumi
    Sato, Kei
    Sugiura, Emiyo
    Nakamori, Shiro
    Fujimoto, Naoki
    Kitagawa, Kakuya
    Sakuma, Hajime
    Dohi, Kaoru
    JOURNAL OF CARDIOLOGY, 2023, 81 (05) : 476 - 484