Reduction with zinc - Impact on the determination of nitrite and nitrate ions using microfluidic paper-based analytical devices

被引:2
|
作者
Umeda, Mika I. [1 ,2 ]
Danchana, Kaewta [2 ]
Fujii, Takatoshi [1 ]
Hino, Eiichi [1 ]
Date, Yusuke [1 ]
Aoki, Kaoru [1 ]
Kaneta, Takashi [2 ]
机构
[1] Yonago Coll, Natl Inst Technol, 4448 Hikona Cho, Yonago, Tottori 6838502, Japan
[2] Okayama Univ, 3-1-1 Tsushimanaka,Kita ku, Okayama 7008530, Japan
来源
TALANTA OPEN | 2024年 / 10卷
关键词
Microfluidic paper-based analytical device; Nitrite ion; Nitrate ion; On-site analysis; Environmental analysis; SPECTROPHOTOMETRIC METHOD; PLATFORM; SAMPLES; SALIVA; WATER; FOOD;
D O I
10.1016/j.talo.2024.100347
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We used a microfluidic paper-based analytical device (mu PAD) to investigate the influence that zinc reduction exerts on the determination of nitrite and nitrate ions in natural water samples. The mu PAD consists of layered channels for the reduction of nitrate to nitrite with zinc powder and the subsequent detection of nitrite with Griess reagent. The amount of zinc, number of layers, and reaction time for the reduction were optimized to obtain an intense signal for nitrate. Initially, the sensitivity to nitrate corresponded to 55% that of nitrite, which implied an incomplete reduction. We found, however, that zinc decreased the sensitivity to nitrite in both the mu PAD and spectrophotometry. The sensitivity to nitrite was decreased by 48% in spectrophotometry and 68% in the mu PAD following the reaction with zinc. One of the reasons for the decreased sensitivity is attributed to the production of ammonia, as we elucidated that both nitrite and nitrate produced ammonia via the reaction with zinc. The results suggest that the total concentration of nitrite and nitrate must be corrected by constructing a calibration curve for nitrite with zinc, in addition to developing curves for nitrate with zinc and for nitrite without zinc. Using these calibration curves, the absorbance at different concentration ratios of nitrite and nitrate ions could be reproduced via calculation using the calibration curves with zinc for nitrite and nitrate. Eventually, the developed mu PAD was applied to the determination of nitrite and nitrate ions in natural water samples, and the results were compared with those using a conventional spectrophotometric method. The results of the mu PAD are in good agreement with those of conventional spectrophotometry, which suggests that the mu PAD is reliable for the measurement of nitrite and nitrate ions in natural water samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Determination of nitrite in saliva using microfluidic paper-based analytical devices
    Bhakta, Samir A.
    Borba, Rubiane
    Taba, Mario, Jr.
    Garcia, Carlos D.
    Carrilho, Emanuel
    ANALYTICA CHIMICA ACTA, 2014, 809 : 117 - 122
  • [2] Microfluidic Paper-based Analytical Devices for On-site Environmental Analysis
    Umeda, Mika I.
    Kaneta, Takashi
    BUNSEKI KAGAKU, 2024, 73 (09) : 433 - 439
  • [3] Determination of nitrite ions in environment analysis with a paper-based microfluidic device
    Liu, Yu-Ci
    Hsu, Chia-Hui
    Lu, Bing-Jyun
    Lin, Peng-Yi
    Ho, Mei-Lin
    DALTON TRANSACTIONS, 2018, 47 (41) : 14799 - 14807
  • [4] Determination of Iron Ion in the Water of a Natural Hot Spring Using Microfluidic Paper-based Analytical Devices
    Ogawa, Kazuma
    Kaneta, Takashi
    ANALYTICAL SCIENCES, 2016, 32 (01) : 31 - 34
  • [5] Development of paper-based microfluidic device for the determination of nitrite in meat
    Trofimchuk, Evan
    Hu, Yaxi
    Nilghaz, Azadeh
    Hua, Marti Z.
    Sun, Selina
    Lu, Xiaonan
    FOOD CHEMISTRY, 2020, 316
  • [6] Microfluidic Paper-based Analytical Devices for Determination of Creatinine in Urine Samples
    Sununta, Suphanan
    Rattanarat, Poomrat
    Challapakul, Orawon
    Praphairaksit, Narong
    ANALYTICAL SCIENCES, 2018, 34 (01) : 109 - 113
  • [7] Determination of Iron Ion in the Water of a Natural Hot Spring Using Microfluidic Paper-based Analytical Devices
    Kazuma Ogawa
    Takashi Kaneta
    Analytical Sciences, 2016, 32 : 31 - 34
  • [8] Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
    Sriram, Ganesan
    Bhat, Mahesh P.
    Patil, Pravin
    Uthappa, Uluvangada T.
    Jung, Ho-Young
    Altalhi, Tariq
    Kumeria, Tushar
    Aminabhavi, Tejraj M.
    Pai, Ranjith Krishna
    Madhuprasad
    Kurkuri, Mahaveer D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 : 212 - 227
  • [9] An environmentally friendly microfluidic paper-based analytical device for simultaneous colorimetric detection of nitrite and nitrate in food products
    Thongkam, Thinikan
    Hemavibool, Khuanjit
    MICROCHEMICAL JOURNAL, 2020, 159
  • [10] Microfluidic Paper-Based Analytical Devices for the Determination of Food Contaminants: Developments and Applications
    Wang, Minglu
    Cui, Jiarui
    Wang, Ying
    Yang, Liu
    Jia, Zhenzhen
    Gao, Chuanjie
    Zhang, Hongyan
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2022, 70 (27) : 8188 - 8206