Flow reversals in a natural circulation loop at atmospheric pressure

被引:0
作者
de Vaux, S. Renaudiere [1 ]
Aubert, P. [2 ]
Grosjean, B. [1 ]
Rossi, L. [2 ]
机构
[1] CEA Cadarache, Serv Etud Syst Innovants SESI, French Atom Energy Commiss, DES,IRESNE,DER, F-13108 St Paul Les Durance, France
[2] CEA Cadarache, Serv Technol Composants & Procedes STCP, French Atom Energy Commiss, DES,IRESNE,DTN, F-13108 St Paul Les Durance, France
关键词
Natural circulation; Thermal-hydraulics; Stability; Experiment; System-scale code; Pressure losses; DENSITY WAVE OSCILLATION; HEAT-FLUX CHF; WATER-FLOW; INSTABILITY; RELAP5; TUBES; CODE;
D O I
10.1016/j.ijheatmasstransfer.2024.126119
中图分类号
O414.1 [热力学];
学科分类号
摘要
Natural circulation in a two-phase water loop, with imposed wall power, is investigated at atmospheric pressure both experimentally and numerically, using the system-scale code CATHARE. Low-pressure loops are prone to instability due to strong differences of density between the liquid and the vapor. Particular attention is devoted to analyzing the boundaries of the flow reversal regime with respect to flow cross section aperture (related to friction forces and experimentally performed using regulation valves) upstream and downstream of the heated test-section. At low heat flux, the flow is stationary, whereas at higher heat flux, flow reversal appears. The system-scale code is amenable to reproduce the flow reversal regime boundaries explored experimentally. An analytical criterion is used to highlight that boiling may become unstable and flow reversals appear. Results show that the stable flow region boundaries can be extended by increasing the upstream pressure loss coefficient (valve closing) in order to reach large exit void fractions alpha approximate to 1. In configurations where the upstream pressure losses dominate, stable boiling points with high mass flux and high heat flux are observed. On the opposite, larger downstream pressure loss coefficients strongly favor instability and flow reversal.
引用
收藏
页数:14
相关论文
共 37 条
  • [11] The 2006 CHF look-up table
    Groeneveld, D. C.
    Shan, J. Q.
    Vasic, A. Z.
    Leung, L. K. H.
    Durmayaz, A.
    Yang, J.
    Cheng, S. C.
    Tanase, A.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2007, 237 (15-17) : 1909 - 1922
  • [12] Theoretical and experimental study on density wave oscillation of two-phase natural circulation of low equilibrium quality
    Guanghui, S
    Dounan, J
    Fukuda, K
    Yujun, G
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2002, 215 (03) : 187 - 198
  • [13] Critical heat flux (CHF) for water flow in tubes - II. Subcooled CHF correlations
    Hall, DD
    Mudawar, I
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (14) : 2605 - 2640
  • [14] Critical heat flux (CHF) for water flow in tubes - I. Compilation and assessment of world CHF data
    Hall, DD
    Mudawar, I
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (14) : 2573 - 2604
  • [15] IdelCik I., 1986, Memento des pertes de charge: coefficients de pertes de charge singulieres et de pertes de charge par frottement
  • [16] Ishii M., 1971, THERMALLY INDUCED FL
  • [17] Ishii M, 2011, THERMO-FLUID DYNAMICS OF TWO-PHASE FLOW, SECOND EDITION, P1, DOI 10.1007/978-1-4419-7985-8
  • [18] Ishii Mamoru., 2016, Investigation of Natural Circulation Instability and Transients in Passively Safe Small Modular Reactors: Reactor Concepts Research Development and Demonstration
  • [19] Experimental investigation on the flow instability behavior of a multi-channel boiling natural circulation loop at low-pressures
    Jain, Vikas
    Nayak, A. K.
    Vijayan, P. K.
    Saha, D.
    Sinha, R. K.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (06) : 776 - 787
  • [20] Jeng H., 1994, P 4 INT TOP M NUCL T, V1