摘要
Many buildings around the world fail to meet current earthquake resistance requirements and have significant potential to be a risk to human life and property. Therefore, a seismic upgrade of such buildings is quite necessary. Over the past decades, hundreds of buildings have been strengthened and upgraded to improve their seismic resistance, and thousands more are planned for years to come. In Israel, this was followed by National Outline Plan No. 38, which provides a basis for retrofitting and adding new areas to existing buildings. It should be noted that adding new floors to existing buildings increases seismic forces. Moreover, structure material properties change over a building's lifetime, which should be also considered for strengthening. The proposed research investigates and validates the existing practice for strengthening and upgrading buildings in seismic regions and suggests ways of improving their efficiency. Experiments and numerical analysis were performed on a real existing residential building that requires strengthening and upgrading. A corresponding methodology was proposed for monitoring the strengthening and upgrading processes, including selecting measurement devices and their real use. Using sensors with the highest sensitivity enabled measurements of micro-vibrations and investigations of the recorded signal to obtain the building's natural vibration frequencies. Experimental measurements allowed us to distinguish different frequencies of the building at all strengthening and upgrading stages. The measured dynamic parameters of the building allowed a more accurate calculation of seismic forces for all of these stages and consequently made the design more effective. Therefore, we recommended monitoring buildings in each stage of seismic strengthening and upgrading.
引用
收藏
页数:16
相关论文
共 26 条
[1]  
[Anonymous], 2014, STRAP Verification Manual, Structural Analysis Program
[2]  
[Anonymous], 2003, EN 1998-3
[3]  
[Anonymous], 2013, IS 413
[4]  
[Anonymous], 2016, ETABS Verification Examples, CSI Computers and Structures
[5]  
[Anonymous], 2003, 19981 EN
[6]  
[Anonymous], 2013, ASCE 7-05
[7]   Do Low-Cost Seismographs Perform Well Enough for Your Network? An Overview of Laboratory Tests and Field Observations of the OSOP Raspberry Shake 4D [J].
Anthony, Robert E. ;
Ringler, Adam T. ;
Wilson, David C. ;
Wolin, Emily .
SEISMOLOGICAL RESEARCH LETTERS, 2019, 90 (01) :219-228
[8]  
Canbay E, 2003, ACI STRUCT J, V100, P637
[9]   Full-Scale Structural and Nonstructural Building System Performance during Earthquakes: Part I - Specimen Description, Test Protocol, and Structural Response [J].
Chen, Michelle C. ;
Pantoli, Elide ;
Wang, Xiang ;
Astroza, Rodrigo ;
Ebrahimian, Hamed ;
Hutchinson, Tara C. ;
Conte, Joel P. ;
Restrepo, Jose I. ;
Marin, Claudia ;
Walsh, Kenneth D. ;
Bachman, Robert E. ;
Hoehler, Matthew S. ;
Englekirk, Robert ;
Faghihi, Mahmoud .
EARTHQUAKE SPECTRA, 2016, 32 (02) :737-770
[10]  
Fajfar P., 1982, Compression of Numerical Analysis and Full-Scale Tests for Free Vibration of Three Reinforced Concrete Buildings, P24