Saliva-STAT: Sample-to-answer saliva test for COVID-19

被引:3
作者
Boegner, David J. [1 ]
Rzasa, John R. [2 ]
Benke, Evan H. [1 ]
White, Ian M. [1 ]
机构
[1] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20742 USA
[2] Univ Maryland, Robert E Fischell Inst Biomed Devices, College Pk, MD 20742 USA
关键词
COVID-19; SARS-CoV-2; Saliva; Sample-to-answer; Point-of-care; LAMP; PARTITIONS;
D O I
10.1016/j.snb.2024.136510
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly accessible and highly accurate diagnostics are necessary to combat rapidly-spreading infectious diseases, such as the recent COVID-19 pandemic. While lateral flow antigen tests have become pervasive, they are insufficiently sensitive to detect early or asymptomatic disease. Nucleic acid amplification tests provide the needed sensitivity, but accessibility of these tests continues to be a challenge due to the need for precise sample processing steps. Here we report a sample-to-answer test for saliva samples (saliva-STAT) that utilizes a batterypowered handheld instrument and a low-cost easily-manufacturable sample cassette to perform a nucleic acid amplification test for viral pathogens. To enable a completely automated assay, we leverage thermally responsive alkane partitions (TRAPs) and paramagnetic beads for virus purification and concentration, as well as reagent addition and mixing. Notably, the saliva STAT easily accommodates directly-dispensed saliva samples (in contrast to microfluidic devices), which is necessary for self-testing. Using the saliva-STAT platform, we demonstrate detection of down to 0.2 copies/mu L of SARS-CoV-2 virus in saliva samples. We envision that the saliva-STAT could be used in walk-in clinics, mobile clinics, public testing locations, and in the home. With minor adjustments to the assay, the saliva-STAT platform can easily be adapted for other respiratory viruses, such as Influenza.
引用
收藏
页数:7
相关论文
共 29 条
[1]  
[Anonymous], EMERGENCY USE AUTHOR
[2]   Saliva is a reliable tool to detect SARS-CoV-2 [J].
Azzi, Lorenzo ;
Carcano, Giulio ;
Gianfagna, Francesco ;
Grossi, Paolo ;
Dalla Gasperina, Daniela ;
Genoni, Angelo ;
Fasano, Mauro ;
Sessa, Fausto ;
Tettamanti, Lucia ;
Carinci, Francesco ;
Maurino, Vittorio ;
Rossi, Agostino ;
Tagliabue, Angelo ;
Baj, Andreina .
JOURNAL OF INFECTION, 2020, 81 (01) :E45-E50
[3]   The COVID-19 pandemic and health inequalities [J].
Bambra, Clare ;
Riordan, Ryan ;
Ford, John ;
Matthews, Fiona .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2020, 74 (11) :964-968
[4]   Thermally Responsive Alkane Partitions for Assay Automation [J].
Boegner, David J. ;
Everitt, Micaela L. ;
White, Ian M. .
ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (07) :8865-8875
[5]   The COVID-19 Pandemic and the $16 Trillion Virus [J].
Cutler, David M. ;
Summers, Lawrence H. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 324 (15) :1495-1496
[6]  
data.who, WHO COVID-19 dashboard
[7]   Long COVID: major findings, mechanisms and recommendations [J].
Davis, Hannah E. ;
McCorkell, Lisa ;
Vogel, Julia Moore ;
Topol, Eric J. .
NATURE REVIEWS MICROBIOLOGY, 2023, 21 (03) :133-146
[8]   Learning loss due to school closures during the COVID-19 pandemic [J].
Engzell, Per ;
Frey, Arun ;
Verhagen, Mark D. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (17)
[9]   Sample-to-Answer Immuno-Magnetic Assay Using Thermally Responsive Alkane Partitions [J].
Everitt, Micaela L. ;
Boegner, David J. ;
White, Ian M. .
BIOSENSORS-BASEL, 2022, 12 (11)
[10]   Sample-to-Answer Diagnostic System for the Detection of Circulating Histones in Whole Blood [J].
Everitt, Micaela L. ;
Boegner, David J. ;
Birukov, Konstantin G. ;
White, Ian M. .
ACS SENSORS, 2021, 6 (08) :3006-3012