Seismic Behavior of RC Columns Strengthened with Textile-Reinforced Ultrahigh-Toughness Cementitious Composite Jackets

被引:3
作者
Hou, Lijun [1 ]
Xu, Ran [2 ]
Yu, Xiaotong [3 ]
Liu, Zikai [3 ]
Liu, Gengsheng [3 ]
Chen, Da [3 ]
机构
[1] Hohai Univ, Key Lab Minist Educ Coastal Disaster & Protect, Nanjing 210098, Peoples R China
[2] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
[3] Hohai Univ, Coll Harbour Coastal & Offshore Engn, Nanjing 210098, Peoples R China
基金
中国国家自然科学基金;
关键词
Textile-reinforced UHTCC (TRU); Seismic performance; Hysteresis behavior; Ductility; Energy dissipation capacity; STRESS-STRAIN MODEL; CONCRETE COLUMNS; CYCLIC BEHAVIOR; BRIDGE COLUMNS; PERFORMANCE; MORTAR; CONFINEMENT; TENSILE; BEAMS;
D O I
10.1061/JCCOF2.CCENG-4432
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Textile-reinforced ultrahigh-toughness cementitious composite (UHTCC) jackets--herein referred to as TRU jackets--are an innovative strengthening system for reinforced concrete (RC) structures. The ductile UHTCC used for this jacket system exhibits better deformation compatibility with the textile than brittle mortar does. In this paper, we present an experimental study of the seismic performance of RC columns strengthened with TRU jackets using cyclic lateral loading tests. The results indicated that the TRU jacket could effectively restrain the development of cracks in the plastic hinge zone, delay stiffness deterioration, and significantly improve ductility and energy dissipation. Moreover, at a low stirrup ratio of 0.39%, the peak load of the jacketed columns was greatly enhanced compared to the peak load of the RC companion columns. With an increased number of textile layers, seismic performance was improved. When the ratio of axial force to axial capacity was increased from 0.15 to 0.30, ductility and energy dissipation did not drop for the TRU-jacketed columns. As the strengthening height decreased from 2.0 to 1.2 times the cross-sectional height of the columns, the seismic performance of the jacketed columns remained almost unchanged. A numerical model was developed for the seismic simulation of TRU-jacketed columns, and the predicted hysteresis curves agree well with the test data.
引用
收藏
页数:19
相关论文
共 57 条
[1]  
AHMAD SH, 1991, ACI STRUCT J, V88, P69
[2]   Using textile reinforced engineered cementitious composite for concrete columns confinement [J].
Al-Gemeerl, Ali Nassir ;
Yan Zhuge .
COMPOSITE STRUCTURES, 2019, 210 :695-706
[3]  
[Anonymous], 2008, Concrete Engineereing Series, V82, P6
[4]   Textile-Reinforced Mortar versus FRP Jacketing in Seismic Retrofitting of RC Columns with Continuous or Lap-Spliced Deformed Bars [J].
Bournas, D. A. ;
Triantafillou, T. C. ;
Zygouris, K. ;
Stavropoulos, F. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2009, 13 (05) :360-371
[5]  
Bournas DA, 2007, ACI STRUCT J, V104, P740
[6]   Compressive behaviour of concrete column confined with basalt textile reinforced ECC [J].
Chen, Xuan ;
Zhuge, Yan ;
Al-Gemeel, Ali Nassir ;
Xiong, Zhongming .
ENGINEERING STRUCTURES, 2021, 243
[7]   Strengthening of reinforced concrete columns by High-Performance Fiber-Reinforced Cementitious Composite (HPFRC) sprayed mortar with strengthening bars [J].
Cho, Chang-Geun ;
Han, Byung-Chan ;
Lim, Seung-Chan ;
Morii, Noharu ;
Kim, Jae-Whan .
COMPOSITE STRUCTURES, 2018, 202 :1078-1086
[8]  
Code of China, 2015, Code for seismic design of buildings
[9]  
Code of China, 2010, Metallic materialsTensile testingPart I: Method of testing at ambient temperature
[10]  
Code of China, 2010, Standard for evaluation of concrete compressive strength