Bilateral hip stability variation in the functional ambulation and kinetic parameters after total hip arthroplasty during leveled walking

被引:0
作者
Abd-Eltawab, Amany E. [1 ,2 ]
Elsherbini, Dalia Mahmoud Abdelmonem [3 ]
El Nashar, Eman Mohamad [4 ]
Alshehri, Shaker Hassan [5 ]
Alhefzi, Ali [5 ]
Eldesoqui, Mamdouh [6 ,7 ]
El-Sherbiny, Mohamed [6 ,7 ]
机构
[1] Jouf Univ, Coll Appl Med Sci, Phys Therapy & Hlth Rehabil Dept, Sakaka, Saudi Arabia
[2] Cairo Univ, Fac Phys Therapy, Biomech Dept, Giza, Egypt
[3] Jouf Univ, Coll Appl Med Sci, Dept Clin Lab Sci, Sakaka, Saudi Arabia
[4] King Khalid Univ, Coll Med, Dept Anat, Abha, Saudi Arabia
[5] King Khalid Univ, Coll Med, Dept Orthoped, Abha, Saudi Arabia
[6] AlMaarefa Univ, Coll Med, Dept Basic Med Sci, Riyadh, Saudi Arabia
[7] Mansoura Univ, Fac Med, Dept Human Anat & Embryol, Mansoura, Egypt
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
hip arthroplasty; walking stability; ambulation parameters; ground reaction force; gender variation; MUSCLE STRENGTH; GAIT; EXTENSION; PATTERNS; OUTCOMES; SPEED;
D O I
10.3389/fbioe.2024.1415645
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives This study determines gender variation, comparing the significance level between men and women related to functional ambulation characteristics after hip arthroplasty. The study focuses on the broader female pelvis and how it affects the rehabilitation regimen following total hip arthroplasty.Materials and Methods In this cross-sectional study, 20 cases of right hip arthroplasty were divided into 10 male and 10 female cases, aged 40-65 years. The functional ambulation parameters (walking cadence, gait speed, stride length, and gait cycle time) were acquired from the GAITRite device, as well as kinematic values for hip frontal plane displacement and kinetic parameters for ground response force in the medial-lateral direction.Results An independent t-test showed a significant difference in the kinematic parameter variables for the anterior superior iliac spine, more significant trochanter displacement, and hip abduction angle between the operated and non-operated limbs for each group separately. Regarding the functional ambulation parameters, there was a significant difference in the walking cadence between the operated and non-operated limbs of both male and female groups. Moreover, the output variables of ground reaction force measures revealed significant differences between their operated and non-operated limbs. The linear regression model used was consistent with the current results, demonstrating a weak negative correlation between the abduction angle of the operated hip and gait speed for both male and female groups.Conclusion Based on the findings, we draw the conclusion that improving a rehabilitated physical therapy program for the abductors of both male and female patients' operated and non-operated limbs is essential for normalizing the ground reaction force value, avoiding focus on the operated hip, and reducing the amount of time that the operated hip's abductors must perform. This involves exposing the surgically repaired limb to the risk of post-operative displacement or dislocation, particularly in female patients.
引用
收藏
页数:12
相关论文
共 35 条
[1]   Whole-Body Vibration Impacts on the Degree of Toe Angle and Its Correlation to the Knee Osteoarthritis Index during Level Walking among Female University Students: A Randomized Controlled Trial [J].
Abd-Eltawab, Amany E. ;
Elbandrawy, Asmaa M. ;
Ghanem, Heba B. ;
Ebrahim, Hasnaa A. ;
El-Sherbiny, Mohamed ;
Ibrahim, Ateya Megahed ;
Eladl, Mohamed Ahmed ;
Elsherbini, Dalia Mahmoud Abdelmonem .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (17)
[2]   Sexual Dimorphism Impact on the Ground Reaction Force Acting on the Mediolateral Direction During Level Walking: Hip Abductor Muscle Biomechanics and Its Correlation to GRF Moment Arm [J].
Abd-Eltawab, Amany E. ;
Ameer, Mariam A. ;
Eladl, Mohamed Ahmed ;
El-Sherbiny, Mohamed ;
Ebrahim, Hasnaa Ali ;
Elsherbini, Dalia Mahmoud Abdelmonem .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
[3]   Lower limb biomechanics during gait do not return to normal following total hip arthroplasty [J].
Beaulieu, Melanie L. ;
Lamontagne, Mario ;
Beaule, Paul E. .
GAIT & POSTURE, 2010, 32 (02) :269-273
[4]   Effect of pelvis impact angle on stresses at the femoral neck during falls [J].
Choi, W. J. ;
Robinovitch, S. N. .
JOURNAL OF BIOMECHANICS, 2018, 74 :41-49
[5]   Hip joint mechanics during walking in individuals with mild-to-moderate hip osteoarthritis [J].
Constantinou, Maria ;
Loureiro, Aderson ;
Carty, Christopher ;
Mills, Peter ;
Barrett, Rod .
GAIT & POSTURE, 2017, 53 :162-167
[6]   Post-operative gait analysis in total hip replacement patients-A review of current literature and meta-analysis [J].
Ewen, Alistair M. ;
Stewart, Su ;
Gibson, Alan St Clair ;
Kashyap, Shankar N. ;
Caplan, Nick .
GAIT & POSTURE, 2012, 36 (01) :1-6
[7]   Isometric performance following total hip arthroplasty and rehabilitation [J].
Frost, Karen L. ;
Bertocci, Gina E. ;
Wassinger, Craig A. ;
Munin, Michael C. ;
Burdett, Ray G. ;
Fitzgerald, Shirley G. .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2006, 43 (04) :435-443
[8]  
GenericHall S. J., 2019, Basic Biomechanics, 8e
[9]   Prediction of walking speed one year following hip fracture based on pre-fracture assessments of mobility and physical activity [J].
Heiberg, Kristi Elisabeth ;
Beckmann, Monica ;
Bruun-Olsen, Vigdis .
BMC GERIATRICS, 2024, 24 (01)
[10]   Hemi-arthroplasty with supplemental fixation of greater trochanter to treat failed hip screws of femoral intertrochanteric fracture [J].
Hsu, Chien-Jen ;
Chou, Wen-Ying ;
Chiou, Chou-Ping ;
Chang, Wei-Ning ;
Wong, Chi-Yin .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (08) :841-845