In silico analysis of the patient-specific acetabular cup anteversion safe zone

被引:1
|
作者
Aubert, Thomas [1 ]
Gerard, Philippe [1 ]
Galanzino, Giacomo [1 ]
Marmor, Simon [1 ]
机构
[1] Croix St Simon Hosp, Orthoped Dept, 125 Rue Avron, F-75020 Paris, France
关键词
Total hip arthroplasty; THA; Prosthetic impingement; Spinopelvic mobility; Hip-spine relationship; TOTAL HIP-ARTHROPLASTY; SPINE RELATIONSHIP; DUAL-MOBILITY; COMPONENT; IMPINGEMENT; REPLACEMENT; ORIENTATION; ACCURACY; PLACEMENT; MOTION;
D O I
10.1016/j.otsr.2024.103940
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Various computer-assisted surgical systems claim to improve the accuracy of cup placement in total hip arthroplasties after assessing spinopelvic mobility to prevent prosthetic impingement. However, no study has yet analyzed the extent of the patient-specific cup anteversion safe zones. Hypothesis: We hypothesized that most patients have a safe zone >10 degrees, except those with abnormal spinopelvic mobility, who have a much narrower safe zone. Materials and methods: We simulated the risks of prosthetic impingement using the planned cup anteversion. The consecutive cohort included 341 patients who underwent total hip arthroplasty. Our primary endpoint was the patient-specific impingement-free zone for cup anteversion, which was then divided into four subgroups: 0 degrees, 1 degrees to 5 degrees, 6 degrees to 10 degrees, and >10 degrees. This data was then secondarily analyzed for abnormal spinopelvic mobility (the difference in the spinopelvic tilt [Delta SPT] from a standing to a flexed seated position >20 degrees). Results: The mean anteversion safe zone was 22.8 degrees with 82.4% (281/341) of patients with a zone strictly >10 degrees. The mean safe zone was 8.9 degrees (+/- 9 degrees) in patients with an Delta SPT >= 20 degrees (18.2%), with 37.1% of these patients having a zone of 0 degrees, 16.13% a zone between 1 degrees and 5 degrees, 8.06% a zone between 6 degrees and 10 degrees and 38.71% a zone >10 degrees. The mean safe zone was 25.9 degrees (+/- 9 degrees) in patients with an Delta SPT <20 degrees (81.8%), and the proportion of cases in each zone was 2.51%, 1.08%, 4.3%, and 92.11%, respectively (p < 0.001). Conclusion: The safe zone for anteversion appears to be fairly wide in most patients. However, identifying patients at risk of abnormal spinopelvic mobility seems necessary to identify the two-thirds of patients with a narrow safe zone. Level of evidence: IV; retrospective study
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Transmission detectors are safe and the future for patient-specific QA in radiation therapy
    Rangaraj, Dharanipathy
    Yaddanapudi, Sridhar
    Cai, Jing
    MEDICAL PHYSICS, 2019, 46 (01) : 1 - 4
  • [42] Accuracy of an adjustable patient-specific guide for acetabular alignment in hip replacement surgery (Optihip)
    Shandiz, Mohsen Akbari
    MacKenzie, James R.
    Hunt, Stephen
    Anglin, Carolyn
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (09) : 876 - 889
  • [43] Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty
    Spencer-Gardner, L.
    Pierrepont, J.
    Topham, M.
    Bare, J.
    McMahon, S.
    Shimmin, A. J.
    BONE & JOINT JOURNAL, 2016, 98B (10): : 1342 - 1346
  • [44] Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery
    Shen, Fangyang
    Chen, Bailiang
    Guo, Qingshan
    Qi, Yue
    Shen, Yue
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (02) : 169 - 179
  • [45] Patient-Specific Guides for Total Hip Arthroplasty: A Paired Acetabular and Femoral Implantation Approach
    Stegman, Jacob
    Casstevens, Chris
    Kelley, Todd
    Nistor, Vasile
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (01):
  • [46] Accuracy of Patient-Specific Drilling Guides in Acetabular Fracture Surgery: A Human Cadaver Study
    Meesters, Anne M. L.
    Assink, Nick
    ten Duis, Kaj
    Fennema, Eelco M.
    Kraeima, Joep
    Witjes, Max J. H.
    De Vries, Jean-Paul P. M.
    Stirler, Vincent M. A.
    IJpma, Frank F. A.
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (08):
  • [47] Patient-specific acetabular shape modelling: comparison among sphere, ellipsoid and conchoid parameterisations
    Cerveri, Pietro
    Manzotti, Alfonso
    Baroni, Guido
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (05) : 560 - 567
  • [48] Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery
    Fangyang Shen
    Bailiang Chen
    Qingshan Guo
    Yue Qi
    Yue Shen
    International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 169 - 179
  • [49] In silico patient-specific optimization of correction strategies for thoracic adolescent idiopathic scoliosis
    La Barbera, Luigi
    Larson, A. Noelle
    Rawlinson, Jeremy
    Aubin, Carl-Eric
    CLINICAL BIOMECHANICS, 2021, 81
  • [50] In silico modeling of patient-specific blood rheology in type 2 diabetes mellitus
    Han, Keqin
    Ma, Shuhao
    Sun, Jiehui
    Xu, Miao
    Qi, Xiaojing
    Wang, Shuo
    Li, Li
    Li, Xuejin
    BIOPHYSICAL JOURNAL, 2023, 122 (08) : 1445 - 1458