Incidence and predictors of vascular complications following transcatheter aortic valve implantation: A comparison of the MANTA and suture-based vascular closure devices

被引:0
作者
Sehgal, Kartik [1 ]
Butala, Anant D. [1 ]
Stub, Dion [1 ,2 ,3 ]
Palmer, Sonny [1 ,4 ]
Noaman, Samer [1 ]
Haji, Kawa [1 ]
Htun, Nay [1 ,2 ]
Johnston, Rozanne [1 ]
Walton, Antony [1 ,5 ]
Nanayakkara, Shane [1 ,2 ,5 ,6 ]
机构
[1] Alfred Hlth, Dept Cardiol, Melbourne, Vic, Australia
[2] Cabrini Hosp, Dept Cardiol, Melbourne, Vic, Australia
[3] Monash Univ, Sch Publ Hlth & Preventat Med, Melbourne, Vic, Australia
[4] Univ Melbourne, Dept Med, Melbourne, Vic, Australia
[5] Epworth Med Fdn, Dept Cardiol, Melbourne, Vic, Australia
[6] Monash Univ, Monash Alfred Baker Ctr Cardiovasc Res, Melbourne, Vic, Australia
关键词
aortic stenosis; transcatheter aortic valve implantation; vascular closure device; vascular complication; CLINICAL-OUTCOMES; ACCESS; MANAGEMENT; ANEMIA; IMPACT;
D O I
10.1002/ccd.31185
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundVascular complications post-transcatheter aortic valve implantation (TAVI) are common. Recent data regarding predictors of vascular complications are limited, particularly comparing newer plug-based devices versus traditional suture-based vascular closure devices (VCD).AimThe primary objective was to identify characteristics that predict a higher risk of vascular complications in TAVI patients, as judged by the VARC-3 criteria, specifically comparing risk factors between suture-based vs MANTA device closure.MethodsRetrospective analysis of patients who underwent TAVI between December 2019 and September 2023 was performed. Logistic regression and propensity score matching was performed to ascertain risk factors for vascular complications post-TAVI.ResultsOf the 1763 patients, there were 106 vascular complications (6%). There was a nonsignificant increased complication rate in MANTA vs suture-based device closure (8.3% vs 5.3%, p = 0.064). Among these, the most common complications were VCD failure (23%), pseudoaneurysm (20%) and arterial dissection (19%). Obesity (p = 0.021), anemia (p = 0.039) and MANTA device use (p = 0.027) were predictors of vascular complications. Within the MANTA cohort, novel oral anticoagulant (NOAC) use was predictive of vascular complications (p = 0.002). Among suture-based devices, obesity (p = 0.037) and anaemia (p = 0.017) were significant predictors. A propensity matched analysis derived 90 pairs of patients matched for age, gender, diabetes, peripheral arterial disease, NOAC use, anemia and obesity, identifying an average treatment effect of 0.039 (p = 0.04) when MANTA device closure was performed.ConclusionVascular complications in TAVI remain common. Identifying predictors such as MANTA device closure, obesity, anemia, and baseline NOAC use will allow for improved risk stratification and appropriate VCD selection in patients undergoing TAVI.
引用
收藏
页码:812 / 819
页数:8
相关论文
共 50 条
  • [41] Acute kidney injury following transcatheter aortic valve implantation: incidence, predictors and clinical outcome
    Saia, Francesco
    Ciuca, Cristina
    Taglieri, Nevio
    Marrozzini, Cinzia
    Savini, Carlo
    Bordoni, Barbara
    Dall'Ara, Gianni
    Moretti, Carolina
    Pilato, Emanuele
    Martin-Suarez, Sofia
    Petridis, Francesco Dimitri
    Di Bartolomeo, Roberto
    Branzi, Angelo
    Marzocchi, Antonio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1034 - 1040
  • [42] Editorial: Transcatheter Aortic Valve Implantation: All Transfemoral? Update on Vascular Acccess and Closure
    Cerillo, Alfredo Giuseppe
    Voetsch, Andreas
    Michel, Jonathan
    Ruge, Hendrik
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [43] On MANTA vascular closure devices following veno arterial extracorporeal membrane oxygenation: Effectiveness and complications
    Berezin, Alexander E.
    WORLD JOURNAL OF CARDIOLOGY, 2025, 17 (03):
  • [44] Incidence and Predictors of Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Implantation: Analysis from the German Transcatheter Aortic Valve Interventions Registry
    Ledwoch, Jakob
    Franke, Jennifer
    Gerckens, Ulrich
    Kuck, Karl-Heinz
    Linke, Axel
    Nickenig, Georg
    Kruells-Muench, Juergen
    Voehringer, Matthias
    Hambrecht, Rainer
    Erbel, Raimund
    Richardt, Gert
    Horack, Martin
    Zahn, Ralf
    Senges, Jochen
    Sievert, Horst
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (04) : E569 - E577
  • [45] Predictors and incidence of access site complications in transcatheter aortic valve implantation with the use of new delivery systems
    Sari, C.
    Ayhan, H.
    Aslan, A. N.
    Durmaz, T.
    Keles, T.
    Bastug, S.
    Bayram, N. Akar
    Bilen, E.
    Kasapkara, H. A.
    Bozkurt, E.
    PERFUSION-UK, 2015, 30 (08): : 666 - 674
  • [46] The adjunctive use of Angio-Seal in femoral vascular closure following percutaneous transcatheter aortic valve replacement
    Kiramijyan, Sarkis
    Magalhaes, Marco A.
    Ben-Dor, Itsik
    Koifman, Edward
    Escarcega, Ricardo O.
    Baker, Nevin C.
    Torguson, Rebecca
    Okubagzi, Petros
    Bernardo, Nelson L.
    Satler, Lowell F.
    Pichard, Augusto D.
    Waksman, Ron
    EUROINTERVENTION, 2016, 12 (01) : 88 - 93
  • [47] Management of Vascular Access in Transcatheter Aortic Valve Replacement Part 2: Vascular Complications
    Toggweiler, Stefan
    Leipsic, Jonathon
    Binder, Ronald K.
    Freeman, Melanie
    Barbanti, Marco
    Heijmen, Robin H.
    Wood, David A.
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (08) : 767 - 776
  • [48] A comparison of conventional surgery versus a vascular closure device for femoral artery repair following transcatheter aortic valve replacement
    Akpinar, Mehmet Besir
    Gul, Ilker
    Sahin, Veysel
    Tastan, Ahmet
    Uyar, Ihsan Sami
    Uc, Halil
    Kiris, Ilker
    Okur, Faik Fevzi
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 24 (04): : 680 - 688
  • [49] Incidence and predictors of coronary obstruction following transcatheter aortic valve implantation in the real world
    Arai, Takahide
    Lefevre, Thierry
    Hovasse, Thomas
    Garot, Philippe
    Benamer, Hakim
    Unterseeh, Thierry
    Roy, Andrew K.
    Romano, Mauro
    Hayashida, Kentaro
    Watanabe, Yusuke
    Bouvier, Erik
    Morice, Marie-Claude
    Chevalier, Bernard
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (07) : 1192 - 1197
  • [50] Vascular complications after transcatheter aortic valve implantation (TAVI): risk and long-term results
    Czerwinska-Jelonkiewicz, Katarzyna
    Michalowska, Ilona
    Witkowski, Adam
    Dabrowski, Maciej
    Ksiezycka-Majczynska, Ewa
    Chmielak, Zbigniew
    Kusmierski, Krzysztof
    Hryniewiecki, Tomasz
    Demkow, Marcin
    Stepinska, Janina
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2014, 37 (04) : 490 - 498