Seismic performance analysis of steel frame structures with separated three-dimensional isolation

被引:0
|
作者
Shi, Yundong [1 ,2 ]
Wang, Yuchen [2 ]
Zhang, Mengmeng [2 ]
Ding, Yang [1 ,2 ]
Li, Zhong-Xian [1 ,2 ]
机构
[1] Tianjin Univ, Key Lab Coast Civil Struct Safety China Minist Edu, Tianjin, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin, Peoples R China
来源
关键词
isolation mechanism; rocking behavior; seismic performance; separated three-dimensional isolation; shaking table test; vertical isolation; ISOLATION SYSTEMS; DESIGN;
D O I
10.1002/eer2.41
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Three-dimensional (3D) base isolation can significantly improve the seismic performance of structures. However, significant 3D movement coupling and rocking behavior of the superstructure due to the high gravity center of the structure can be observed, which will lead to a complex design of the isolation system and the isolators. In addition, as the 3D isolators are installed beneath the structures, they need to support the heavy weight of the superstructure with low vertical stiffness. It is difficult to meet both the vertical load and stiffness design demands of the isolators using traditional isolation materials and mechanisms, especially for large-size structures. A separated 3D isolation scheme is proposed by installing the horizontal isolation at the base of the superstructure and the vertical isolation under the floor slabs. Simulations are carried out to examine the dynamic responses including the acceleration, inter-storey drift, and stress of structural members of a typical steel frame structure with the separated 3D isolation scheme. The isolation effect was also studied by shaking table tests of a two-storey steel frame structure. The simulation and test results show that the proposed separated 3D isolation scheme has high performance in mitigating the structural accelerations in both horizontal and vertical directions, and the vertical load on isolators. The rocking behavior of the structure is effectively restrained for the separated 3D isolation scheme due to a low mass center configuration of the vertically isolated slabs. Although the isolation of the floor slabs from the beams in the structure with separated 3D isolation weakens the constraint of the floor slabs to the beam and column members as in a traditional frame structure, the horizontal isolation at the base of the superstructure reduces the adverse effect and the stress of structural members is similar to that in a horizontal base-isolated structure and significantly lower than that in a base-fixed structure. In addition, as the vertical isolation is installed under the slabs, the vertical load on the vertical isolators is small and it is easy to design the isolators. A separated three-dimensional isolation scheme for steel frame structures is proposed by installing horizontal isolation at the base and vertical isolation beneath the floor slabs. It can achieve a high isolation effect, mitigate the motion coupling, and restrain the rocking behavior significantly without any rocking constraint devices, thus protecting the structure and nonstructural components. Besides, the vertical load on vertical isolators is significantly reduced, making it easy to design and manufacture. image
引用
收藏
页码:52 / 73
页数:22
相关论文
共 50 条
  • [41] Three-dimensional nonlinear seismic performance evaluation of retrofit measures for typical steel girder bridges
    Padgett, Jamie E.
    DesRoches, Reginald
    ENGINEERING STRUCTURES, 2008, 30 (07) : 1869 - 1878
  • [42] Three-dimensional scattering of seismic waves from topographical structures
    Reinoso, E
    Wrobel, LC
    Power, H
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 1997, 16 (01) : 41 - 61
  • [43] Three-dimensional non-linear seismic analysis of asymmetric structures on elastic soil
    Teymoorian, Ehsan
    Halabian, Amir M.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2022, 175 (11) : 827 - 846
  • [44] A three-dimensional animation system for seismic response of multistory structures
    Konicki, MG
    Adeli, H
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1997, 8 (03) : 313 - 321
  • [45] Three-dimensional seismic response analysis of metro station structures and tunnels in soft soil
    Wang Guo-bo
    Ma Xian-feng
    Yang Lin-de
    ROCK AND SOIL MECHANICS, 2009, 30 (08) : 2523 - 2528
  • [46] The Seismic Performance Analysis of Steel Frame Adding the Viscoelastic Dampers
    Wang, Yali
    Lei, Jinsong
    Zheng, Feihua
    Zhai, Kanglan
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 2461 - 2466
  • [47] Linear analysis of a three-dimensional multistorey steel-frame structure under varying temperatures
    Parthasarathi, N.
    Satyanarayanan, K. S.
    Thamilarau, V
    Prakash, M.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2019, 10 (01) : 110 - 122
  • [48] Three-Dimensional Effects and Collapse Resistance Mechanisms in Steel Frame Buildings
    Li, Honghao
    El-Tawil, Sherif
    JOURNAL OF STRUCTURAL ENGINEERING, 2014, 140 (08)
  • [49] Study of Isolation Effectiveness of Nuclear Reactor Building with Three-dimensional Seismic Base Isolation
    Zhu X.
    Li J.
    Pan R.
    Sun F.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2023, 57 (02): : 438 - 448
  • [50] Study of isolation effectiveness of nuclear reactor building with three-dimensional seismic base isolation
    Zhu, Xiuyun
    Pan, Rong
    Li, Jianbo
    Lin, Gao
    ENGINEERING COMPUTATIONS, 2022, 39 (04) : 1209 - 1233