Seismic performance analysis of steel frame structures with separated three-dimensional isolation

被引:0
|
作者
Shi, Yundong [1 ,2 ]
Wang, Yuchen [2 ]
Zhang, Mengmeng [2 ]
Ding, Yang [1 ,2 ]
Li, Zhong-Xian [1 ,2 ]
机构
[1] Tianjin Univ, Key Lab Coast Civil Struct Safety China Minist Edu, Tianjin, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin, Peoples R China
来源
EARTHQUAKE ENGINEERING AND RESILIENCE | 2023年 / 2卷 / 01期
关键词
isolation mechanism; rocking behavior; seismic performance; separated three-dimensional isolation; shaking table test; vertical isolation; ISOLATION SYSTEMS; DESIGN;
D O I
10.1002/eer2.41
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Three-dimensional (3D) base isolation can significantly improve the seismic performance of structures. However, significant 3D movement coupling and rocking behavior of the superstructure due to the high gravity center of the structure can be observed, which will lead to a complex design of the isolation system and the isolators. In addition, as the 3D isolators are installed beneath the structures, they need to support the heavy weight of the superstructure with low vertical stiffness. It is difficult to meet both the vertical load and stiffness design demands of the isolators using traditional isolation materials and mechanisms, especially for large-size structures. A separated 3D isolation scheme is proposed by installing the horizontal isolation at the base of the superstructure and the vertical isolation under the floor slabs. Simulations are carried out to examine the dynamic responses including the acceleration, inter-storey drift, and stress of structural members of a typical steel frame structure with the separated 3D isolation scheme. The isolation effect was also studied by shaking table tests of a two-storey steel frame structure. The simulation and test results show that the proposed separated 3D isolation scheme has high performance in mitigating the structural accelerations in both horizontal and vertical directions, and the vertical load on isolators. The rocking behavior of the structure is effectively restrained for the separated 3D isolation scheme due to a low mass center configuration of the vertically isolated slabs. Although the isolation of the floor slabs from the beams in the structure with separated 3D isolation weakens the constraint of the floor slabs to the beam and column members as in a traditional frame structure, the horizontal isolation at the base of the superstructure reduces the adverse effect and the stress of structural members is similar to that in a horizontal base-isolated structure and significantly lower than that in a base-fixed structure. In addition, as the vertical isolation is installed under the slabs, the vertical load on the vertical isolators is small and it is easy to design the isolators. A separated three-dimensional isolation scheme for steel frame structures is proposed by installing horizontal isolation at the base and vertical isolation beneath the floor slabs. It can achieve a high isolation effect, mitigate the motion coupling, and restrain the rocking behavior significantly without any rocking constraint devices, thus protecting the structure and nonstructural components. Besides, the vertical load on vertical isolators is significantly reduced, making it easy to design and manufacture. image
引用
收藏
页码:52 / 73
页数:22
相关论文
共 50 条
  • [31] Seismic mitigation analysis of three-dimensional base-isolated nuclear structures with soil-dependent isolation system under extreme earthquakes
    Liu, Yu
    Li, Jianbo
    Lin, Gao
    ENGINEERING STRUCTURES, 2024, 311
  • [32] Seismic performance of RC frame structures strengthened by HPFRCC walls
    Yun, Hyun-Do
    Hwang, Jin-Ha
    Kim, Mee-Yeon
    Choi, Seung-Ho
    Park, Wan-Shin
    Kim, Kang Su
    STRUCTURAL ENGINEERING AND MECHANICS, 2020, 75 (03) : 389 - 399
  • [33] Three-dimensional internal stability analysis of geosynthetic-reinforced earth structures considering seismic loading
    Yang, Shangchuan
    Gao, Yufeng
    Cui, Kai
    Zhang, Fei
    Wu, Di
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2020, 130
  • [34] Shear Fragility Analysis of Non-Classically Damped Three-Dimensional Structures Under Seismic Excitation
    Wang, Jinghui
    Tan, Ping
    Huang, Tiancan
    He, Xuefeng
    Zhou, Fulin
    BUILDINGS, 2024, 14 (12)
  • [35] Seismic performance of advanced three-dimensional base-isolated nuclear structures in complex-layered sites
    Liu, Yu
    Li, Jianbo
    Lin, Gao
    ENGINEERING STRUCTURES, 2023, 289
  • [36] Parameters performance to the vibration isolation in three-dimensional elastic floating raft isolation system
    Jiang, Guohe
    Wu, Gang
    ADVANCED MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 472-475 : 2659 - 2662
  • [37] Study on seismic performance of prefabricated self-centering steel frame
    Yun, Chen
    Chao, Chen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 182
  • [38] The seismic analysis and performance of steel frame with additional low-yield-point steel dampers
    Akbar, Muhammad
    Pan Huali
    Adedamola, Akin-Adewale
    Ou Guoqiang
    Amin, Azka
    JOURNAL OF VIBROENGINEERING, 2021, 23 (03) : 647 - 674
  • [39] A liquid spring-magnetorheological damper system under combined axial and shear loading for three-dimensional seismic isolation of structures
    Cesmeci, Sevki
    Gordaninejad, Faramarz
    Ryan, Keri L.
    Eltahawy, Walaa
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2018, 29 (18) : 3517 - 3532
  • [40] Seismic performance of steel-timber hybrid structures with separated gravity and lateral resisting systems based on incremental dynamic analysis
    Li Z.
    Wang Z.
    He M.
    Shu Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (12): : 1 - 12