Seismic performance analysis of steel frame structures with separated three-dimensional isolation

被引:0
|
作者
Shi, Yundong [1 ,2 ]
Wang, Yuchen [2 ]
Zhang, Mengmeng [2 ]
Ding, Yang [1 ,2 ]
Li, Zhong-Xian [1 ,2 ]
机构
[1] Tianjin Univ, Key Lab Coast Civil Struct Safety China Minist Edu, Tianjin, Peoples R China
[2] Tianjin Univ, Sch Civil Engn, Tianjin, Peoples R China
来源
EARTHQUAKE ENGINEERING AND RESILIENCE | 2023年 / 2卷 / 01期
关键词
isolation mechanism; rocking behavior; seismic performance; separated three-dimensional isolation; shaking table test; vertical isolation; ISOLATION SYSTEMS; DESIGN;
D O I
10.1002/eer2.41
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Three-dimensional (3D) base isolation can significantly improve the seismic performance of structures. However, significant 3D movement coupling and rocking behavior of the superstructure due to the high gravity center of the structure can be observed, which will lead to a complex design of the isolation system and the isolators. In addition, as the 3D isolators are installed beneath the structures, they need to support the heavy weight of the superstructure with low vertical stiffness. It is difficult to meet both the vertical load and stiffness design demands of the isolators using traditional isolation materials and mechanisms, especially for large-size structures. A separated 3D isolation scheme is proposed by installing the horizontal isolation at the base of the superstructure and the vertical isolation under the floor slabs. Simulations are carried out to examine the dynamic responses including the acceleration, inter-storey drift, and stress of structural members of a typical steel frame structure with the separated 3D isolation scheme. The isolation effect was also studied by shaking table tests of a two-storey steel frame structure. The simulation and test results show that the proposed separated 3D isolation scheme has high performance in mitigating the structural accelerations in both horizontal and vertical directions, and the vertical load on isolators. The rocking behavior of the structure is effectively restrained for the separated 3D isolation scheme due to a low mass center configuration of the vertically isolated slabs. Although the isolation of the floor slabs from the beams in the structure with separated 3D isolation weakens the constraint of the floor slabs to the beam and column members as in a traditional frame structure, the horizontal isolation at the base of the superstructure reduces the adverse effect and the stress of structural members is similar to that in a horizontal base-isolated structure and significantly lower than that in a base-fixed structure. In addition, as the vertical isolation is installed under the slabs, the vertical load on the vertical isolators is small and it is easy to design the isolators. A separated three-dimensional isolation scheme for steel frame structures is proposed by installing horizontal isolation at the base and vertical isolation beneath the floor slabs. It can achieve a high isolation effect, mitigate the motion coupling, and restrain the rocking behavior significantly without any rocking constraint devices, thus protecting the structure and nonstructural components. Besides, the vertical load on vertical isolators is significantly reduced, making it easy to design and manufacture. image
引用
收藏
页码:52 / 73
页数:22
相关论文
共 50 条
  • [21] Vertical Seismic Isolation Device for Three-Dimensional Seismic Isolation of Nuclear Power Plant Equipment-Case Study
    Koo, Gyeong-Hoi
    Jung, Jin-Young
    Hwang, Jong-Keun
    Shin, Tae-Myung
    Lee, Min-Seok
    APPLIED SCIENCES-BASEL, 2022, 12 (01):
  • [22] Optimum distribution of steel frame assembly for seismic retrofit of framed structures
    Adane, Michael
    Chun, Seungho
    Kim, Jinkoo
    STEEL AND COMPOSITE STRUCTURES, 2024, 50 (03) : 337 - 345
  • [23] Research on isolation performance of three-dimensional isolation device with vertical variable stiffness for long-span spatial structures
    Chen Z.
    Ding Y.
    Shi Y.
    Li Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (10): : 35 - 42
  • [24] A finite element analysis model for post-fire seismic performance of steel reinforced concrete frame structures
    Wang G.
    Sun X.
    Zhao W.
    Zhang D.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (04): : 92 - 101
  • [25] Seismic Analysis of Hybrid Steel Moment Frame CLT Shear Walls Structures
    Khajehpour, Mehdi
    Pan, Yuxin
    Tannert, Thomas
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2021, 35 (05)
  • [26] The Effect of Damping on Seismic Performance of Steel Frame
    Wang, Xinwu
    Hu, Changjiao
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 1477 - +
  • [27] Potentiality of Using Vertical and Three-Dimensional Isolation Systems in Nuclear Structures
    Zhou, Zhiguang
    Wong, Jenna
    Mahin, Stephen
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2016, 48 (05) : 1237 - 1251
  • [28] Analysis of the seismic performance of RC frame structures with different types of bracings
    Wang, Zhixin
    Fan, Haitao
    Zhao, Huangjuan
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 2209 - 2215
  • [29] Location of semi-rigid connections effect on the seismic performance of steel frame structures
    Elhout, Emad A.
    ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2022, 22 (03): : 1 - 10
  • [30] The influence of gravity column continuity on the seismic performance of special steel moment frame structures
    Flores, F.
    Charney, F.
    Lopez-Garcia, D.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 118 : 217 - 230