Nickel foam-decorated hollow-Co3O4/GO nanocomposites: A highly sensitive non-enzymatic electrochemical sensor for glucose detection

被引:3
|
作者
Wang, Guangyu [1 ,2 ]
Li, Ling [1 ,2 ]
Han, Xinping [1 ,2 ]
Gao, Wenyue [1 ,2 ]
Wang, Cuijuan [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Chem, Chengdu 610031, Sichuan, Peoples R China
[2] Southwest Jiaotong Univ, Sch Life Sci & Engn, Chengdu 610031, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Zeolite imidazole frameworks (ZIFs); Non-enzymatic glucose sensor; Electrochemical detection; GO; Cobalt tetroxide; METAL-ORGANIC FRAMEWORK; CO3O4; ELECTRODE; MEMBRANE;
D O I
10.1016/j.microc.2024.111398
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cobalt-based nanomaterials, characterized by multiple oxidation states and high stability in alkaline environments, have been found extensive applications in glucose detection. In this study, a cobalt-based zeolitic imidazolate framework (ZIF-67) was employed as a precursor, where Co2+ was coordinated with carboxyl groups of oxidized graphene oxide (GO), resulting in the formation of cobalt-based nanoparticles. The integration of Co(2+ )with GO established a novel cobalt-based nanomaterial with potential implications for glucose detection. At a calcination temperature of 260 (degrees C), the calcination process extended for 4 h, fulfilling the synthesis of HollowCo(3)O(4)/GO nanocomposites. These nanocomposites were subsequently engaged as electrochemical electrodes for glucose detection through the impregnation method. The distinctive structure of Hollow-Co3O4/GO has spurred mutual promotion of the reoxidation reactions at the interface, culminating in a substantial augmentation of the specific surface area and a consequent considerable surge in the glucose oxidation current. In addition, due to the retention of the structure of MOFs, the pores can be used to adsorb glucose molecules, which is conducive to the accurate detection of the reaction. Under optimal conditions, the sensitivity of the Hollow-Co3O4/GO modified electrode hits 1582.7 mu A mmol(- 1) cm(- 2), with a detection limit of 0.49 mu mol/L (S/N = 3) and a response time of approximately 2 s. These achievements have emphasized the promising applicability of Hollow-Co3O4/GO nanocomposites as an active material for practical electrochemical biosensors.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Co3O4 nanocubes decorated single-walled carbon nanotubes for efficient electrochemical non-enzymatic glucose sensing
    Liaqat, Iqra
    Iqbal, Naseer
    Aslam, Muhammad
    Nasir, Muhammad
    Hayat, Akhtar
    Han, Dong Xue
    Niu, Li
    Nawaz, Mian Hasnain
    SN APPLIED SCIENCES, 2020, 2 (10):
  • [42] Electrospun porous La-Sr-Co-Ni-O nanofibers for highly sensitive non-enzymatic glucose detection
    Pelucarte, Kasci D.
    Hatchell, Tashi A.
    George, Gibin
    Ede, Sivasankara Rao
    Adhikari, Menuka
    Lin, Yulin
    Wen, Jianguo
    Luo, Zhiping
    Han, Shubo
    MATERIALS ADVANCES, 2022, 3 (04): : 2096 - 2103
  • [43] Co3O4 nanocubes decorated single-walled carbon nanotubes for efficient electrochemical non-enzymatic glucose sensing
    Iqra Liaqat
    Naseer Iqbal
    Muhammad Aslam
    Muhammad Nasir
    Akhtar Hayat
    Dong Xue Han
    Li Niu
    Mian Hasnain Nawaz
    SN Applied Sciences, 2020, 2
  • [44] NiCo-LDH nanoflake arrays-supported Au nanoparticles on copper foam as a highly sensitive electrochemical non-enzymatic glucose sensor
    Shen, Mao
    Li, Wei
    Chen, Lei
    Chen, Yuxiang
    Ren, Shibin
    Han, Deman
    ANALYTICA CHIMICA ACTA, 2021, 1177
  • [45] Nickel Oxide Nano-Particles on 3D Nickel Foam Substrate as a Non-Enzymatic Glucose Sensor
    Hayat, Asif
    Mane, Sunil Kumar Baburao
    Shaishta, Naghma
    Khan, Javid
    Hayat, Ashiq
    Keyum, Guzalnur
    Uddin, Ikram
    Raziq, Fazal
    Khan, Muhammad
    Manjunatha, G.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (15) : B1602 - B1611
  • [46] TiO2 decorated Co3O4 acicular nanotube arrays and its application as a non-enzymatic glucose sensor
    Gao, Zhenfei
    Zhang, Liqiang
    Ma, Chi
    Zhou, Qidong
    Tang, Yushu
    Tu, Zhiqiang
    Yang, Wang
    Cui, Lishan
    Li, Yongfeng
    BIOSENSORS & BIOELECTRONICS, 2016, 80 : 511 - 518
  • [47] Cu2O hollow microspheres as electrode materials for non-enzymatic electrochemical detection of glucose
    Zhang, Fan
    Wang, Yihui
    Wu, Xiujuan
    Zhang, Hao
    Huang, Shan
    Yang, Ying
    Xie, Adi
    Wang, Mingyan
    MICRO & NANO LETTERS, 2020, 15 (15) : 1071 - 1074
  • [48] High-performance non-enzymatic electrochemical glucose detection using Au-decorated Co(OH)F nanoneedles on nickel foam synthesized via hydrothermal method
    Shewale, Prashant Shivaji
    Yun, Kwang-Seok
    MICROCHEMICAL JOURNAL, 2025, 209
  • [49] Highly sensitive and selective rGO based Non-Enzymatic electrochemical sensor for propamocarb fungicide pesticide detection
    Tasaltin, Nevin
    Karakus, Selcan
    Tasaltin, Cihat
    Baytemir, Gulsen
    FOOD CHEMISTRY, 2022, 372
  • [50] Synthesis of NiGa2O4 nanosheets for non-enzymatic glucose electrochemical sensor
    Ding, Longhua
    Yan, Jiahui
    Zhao, Zhongyao
    Li, Dongjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 296