Numerical and Experimental Study of a Single-Slope Solar Still Integrated with Wick Material and External Condenser

被引:0
作者
Hyal, Lujain S. [1 ]
Jalil, Jalal M. [1 ]
Hanfesh, Abduljabbar O. [1 ]
机构
[1] Univ Technol Iraq, Electromech Engn Dept, Baghdad, Iraq
关键词
external condenser; still efficiency; Computational Fluid Dynamics (CFD); jute wick; productivity; CORRUGATED ABSORBER; PERFORMANCE; DISTILLATION; ENHANCEMENT; EFFICIENCY;
D O I
10.18280/ijht.420426
中图分类号
O414.1 [热力学];
学科分类号
摘要
Access to potable water is essential for human existence. This work aims to enhance the performance of single-slope solar still. Two solar stills were employed: A conventional solar still (CSS)served as a reference, and a modified solar still (MSS) Awhich featured a novel design with a floating absorber surface. The objective is to increase the productivity and efficiency of solar still by enhancing the evaporation surface area using wick materials. Multiple ratios of wick material (25%, 50%, 75%, Aand 100%) Awith and without an external condenser were examined to assess their influence on production. Computational Fluid Dynamics (CFD) program was employed to numerically simulate solar distillation under natural and forced convection circumstances, therefore confirming the accuracy of the experimental findings. Based on the outcomes, the increase in productivity reached 25%, 50%, 75%, Aand 100% wick coverage for the MSS were around 33%, 66%, 45%, Aand 16% higher than the productivity achieved with the CSS, Arespectively. With the external condenser, the enhancements increased to 35%, 75%, 50%, Aand 27% compared to the CSS. Daily efficiency of the MSS with wick was 19.19%, Awhile the efficiency increased to 27.13% when both the wick and condenser were used.
引用
收藏
页码:1359 / 1374
页数:16
相关论文
共 45 条
  • [1] Abbas H., 2021, Eng. Technol. J., V39, P846, DOI [10.30684/etj.v39i5A.1980, DOI 10.30684/ETJ.V39I5A.1980]
  • [2] Experimental and numerical investigation of PCM capsules as insulation materials inserted into a hollow brick wall
    Abbas, Hayder M.
    Jalil, Jalal M.
    Ahmed, Sabah T.
    [J]. ENERGY AND BUILDINGS, 2021, 246
  • [3] Increasing the productivity of modified cords pyramid solar still using electric heater and various wick materials
    Abdullah, A. S.
    Alawee, Wissam H.
    Mohammed, Suha A.
    Majdi, Ali
    Omara, Z. M.
    Essa, Fadl A.
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 169 : 169 - 176
  • [4] Experimental investigation of modified solar still coupled with high-frequency ultrasonic vaporizer and phase change material capsules
    Abed, Akram H.
    Hoshi, Hisham Assi
    Jabal, Mohammed Hassan
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [5] Aboud G.A., 2022, Engineering and Technology Journal, V40, P241, DOI [10.30684/etj.v40i1.2282, DOI 10.30684/ETJ.V40I1.2282]
  • [6] Theoretical and experimental performance evaluation of single-slope single-basin solar still with multiple V-shaped floating wicks
    Agrawal, Abhay
    Rana, R. S.
    [J]. HELIYON, 2019, 5 (04)
  • [7] Ahmed S.T., 2020, The Iraqi Journal for Mechanical and Materials Engineering, V20, P193, DOI [10.32852/iqjfmme.v20i3.512, DOI 10.32852/IQJFMME.V20I3.512]
  • [8] Alawee W.H., 2022, Eng. Technol. J., V41, P121, DOI [10.30684/etj.2022.134576.1240, DOI 10.30684/ETJ.2022.134576.1240]
  • [9] Alawee W.H., 2015, 7 INT C SUST AGR FOO
  • [10] Bao N.T., 2019, Distillation - Modelling, Simulation and Optimization, DOI [10.5772/inte-chopen.83228, DOI 10.5772/INTE-CHOPEN.83228]