Improved sensitivity for subsurface imaging by contact resonance atomic force microscopy using Fano peaks

被引:0
作者
Wang, Yuyang [1 ]
Duan, Mingyu [1 ]
Chen, Yuan-Liu [1 ]
机构
[1] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power Transmiss & Control, Hangzhou 310027, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
NANOPARTICLES; CANTILEVERS; FREQUENCY;
D O I
10.1063/5.0219230
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Subsurface detection using contact resonance atomic force microscopy (CR-AFM) has been well-documented and proven capable of nondestructively detecting subsurface defects at depths of hundreds of nanometers. In CR-AFM, the frequency of the contact resonance mode is often used as the actuating frequency of the probe. However, as many frequencies are available in the probe's vibrational spectrum, each with a significant impact on the final measurement result, a focused study on frequency selection is necessary. This paper investigates contact resonance peaks through theoretical modeling and experimental verification. The peaks were categorized into two types based on their symmetry. Comparative studies were conducted on the traditionally used symmetric resonance peaks and the less-studied asymmetric resonance peaks. The results reveal the detection capability for subsurface measurements due to different peak selections, identifying the peak types most suitable for these measurements. This study demonstrates that using Fano peaks in CR-AFM can enhance subsurface imaging resolution and reduce surface damage, making it a valuable technique for detailed nanoscale analysis.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Subsurface Imaging of the Cores of Polymer-Encapsulated Cobalt Nanoparticles Using Force Modulation Microscopy
    Deese, Stephen M.
    Englade-Franklin, Lauren E.
    Hill, Lawrence J.
    Pyun, Jeffrey
    Chan, Julia Y.
    Garno, Jayne C.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2017, 121 (42) : 23498 - 23504
  • [32] Quantitative assessment of contact and non-contact lateral force calibration methods for atomic force microscopy
    Bien Cuong Tran Khac
    Chung, Koo-Hyun
    ULTRAMICROSCOPY, 2016, 161 : 41 - 50
  • [33] A non-contact, thermal noise based method for the calibration of lateral deflection sensitivity in atomic force microscopy
    Mullin, Nic
    Hobbs, Jamie K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11)
  • [34] Modulation of contact resonance frequency accompanying atomic-scale stick-slip in friction force microscopy
    Steiner, Pascal
    Roth, Raphael
    Gnecco, Enrico
    Glatzel, Thilo
    Baratoff, Alexis
    Meyer, Ernst
    NANOTECHNOLOGY, 2009, 20 (49)
  • [35] Atomic force microscopy using small cantilevers
    Walters, DA
    Viani, M
    Paloczi, GT
    Schaffer, TE
    Cleveland, JP
    Wendman, MA
    Gurley, G
    Elings, V
    Hansma, PK
    MICROMACHINING AND IMAGING, 1997, 3009 : 43 - 47
  • [36] Local probe of the interlayer coupling strength of few-layers SnSe by contact-resonance atomic force microscopy
    Zheng, Zhi-Yue
    Pan, Yu-Hao
    Pei, Teng-Fei
    Xu, Rui
    Xu, Kun-Qi
    Lei, Le
    Hussain, Sabir
    Liu, Xiao-Jun
    Bao, Li-Hong
    Gao, Hong-Jun
    Ji, Wei
    Cheng, Zhi-Hai
    FRONTIERS OF PHYSICS, 2020, 15 (06)
  • [37] Optimization and calibration of atomic force microscopy sensitivity in terms of tip-sample interactions in high-order dynamic atomic force microscopy
    Liu, Yu
    Guo, Qiuquan
    Nie, Heng-Yong
    Lau, W. M.
    Yang, Jun
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (12)
  • [38] Theoretical basis of parametric-resonance-based atomic force microscopy
    Prakash, G.
    Hu, S.
    Raman, A.
    Reifenberger, R.
    PHYSICAL REVIEW B, 2009, 79 (09)
  • [39] Accurate Atomic-Scale Imaging of Two-Dimensional Lattices Using Atomic Force Microscopy in Ambient Conditions
    Kim, Sunghyun
    Moon, Donghyeon
    Jeon, Bo Ram
    Yeon, Jegyeong
    Li, Xiaoqin
    Kim, Suenne
    NANOMATERIALS, 2022, 12 (09)
  • [40] Robust atomic force microscopy using multiple sensors
    Baranwal, Mayank
    Gorugantu, Ram S.
    Salapaka, Srinivasa M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (08)