Improved sensitivity for subsurface imaging by contact resonance atomic force microscopy using Fano peaks

被引:0
作者
Wang, Yuyang [1 ]
Duan, Mingyu [1 ]
Chen, Yuan-Liu [1 ]
机构
[1] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power Transmiss & Control, Hangzhou 310027, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
NANOPARTICLES; CANTILEVERS; FREQUENCY;
D O I
10.1063/5.0219230
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Subsurface detection using contact resonance atomic force microscopy (CR-AFM) has been well-documented and proven capable of nondestructively detecting subsurface defects at depths of hundreds of nanometers. In CR-AFM, the frequency of the contact resonance mode is often used as the actuating frequency of the probe. However, as many frequencies are available in the probe's vibrational spectrum, each with a significant impact on the final measurement result, a focused study on frequency selection is necessary. This paper investigates contact resonance peaks through theoretical modeling and experimental verification. The peaks were categorized into two types based on their symmetry. Comparative studies were conducted on the traditionally used symmetric resonance peaks and the less-studied asymmetric resonance peaks. The results reveal the detection capability for subsurface measurements due to different peak selections, identifying the peak types most suitable for these measurements. This study demonstrates that using Fano peaks in CR-AFM can enhance subsurface imaging resolution and reduce surface damage, making it a valuable technique for detailed nanoscale analysis.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Mapping substrate/film adhesion with contact-resonance-frequency atomic force microscopy
    Hurley, D. C.
    Kopycinska-Muller, M.
    Langlois, E. D.
    Kos, A. B.
    Barbosa, N., III
    APPLIED PHYSICS LETTERS, 2006, 89 (02)
  • [22] Actuation of atomic force microscopy microcantilevers using contact acoustic nonlinearities
    Torello, D.
    Degertekin, F. Levent
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (11)
  • [23] Imaging and force probing RNA by atomic force microscopy
    Schon, Peter
    METHODS, 2016, 103 : 25 - 33
  • [24] Liquid-Liquid Interfacial Imaging Using Atomic Force Microscopy
    Costa, Luca
    Li-Destri, Giovanni
    Pontoni, Diego
    Konovalov, Oleg
    Thomson, Neil H.
    ADVANCED MATERIALS INTERFACES, 2017, 4 (16):
  • [25] Vibrational shape tracking of atomic force microscopy cantilevers for improved sensitivity and accuracy of nanomechanical measurements
    Wagner, Ryan
    Killgore, Jason P.
    Tung, Ryan C.
    Raman, Arvind
    Hurley, Donna C.
    NANOTECHNOLOGY, 2015, 26 (04)
  • [26] Cutting down the forest of peaks in acoustic dynamic atomic force microscopy in liquid
    Carrasco, C.
    Ares, P.
    de Pablo, P. J.
    Gomez-Herrero, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (12)
  • [27] Characterization of English ivy (Hedera helix) adhesion force and imaging using atomic force microscopy
    Xia, Lijin
    Lenaghan, Scott C.
    Zhang, Mingjun
    Wu, Yu
    Zhao, Xiaopeng
    Burris, Jason N.
    Stewart, C. Neal, Jr.
    JOURNAL OF NANOPARTICLE RESEARCH, 2011, 13 (03) : 1029 - 1037
  • [28] Viscoelastic Property Mapping with Contact Resonance Force Microscopy
    Killgore, J. P.
    Yablon, D. G.
    Tsou, A. H.
    Gannepalli, A.
    Yuya, P. A.
    Turner, J. A.
    Proksch, R.
    Hurley, D. C.
    LANGMUIR, 2011, 27 (23) : 13983 - 13987
  • [29] Fano-like resonance in an optically driven atomic force microscope cantilever
    Kadri, Shahrul
    Fujiwara, Hideki
    Sasaki, Keiji
    OPTICS EXPRESS, 2011, 19 (03): : 2317 - 2324
  • [30] Effect of contact stiffness on wedge calibration of lateral force in atomic force microscopy
    Wang, Fei
    Zhao, Xuezeng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (04)