Tutorial: A Versatile Bio-Inspired System for Processing and Transmission of Muscular Information

被引:12
作者
Rossi, Fabio [1 ]
Mongardi, Andrea [1 ]
Ros, Paolo Motto [1 ]
Roch, Massimo Ruo [1 ]
Martina, Maurizio [1 ]
Demarchi, Danilo [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, I-10129 Turin, Italy
关键词
Bio-inspired electronics; surface electromyography; bluetooth low energy; event-based; information synthesis; power efficiency; wearable system; WIRELESS; ACQUISITION;
D O I
10.1109/JSEN.2021.3103608
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Device wearability and operating time are trending topics in recent state-of-art works on surface ElectroMyoGraphic (sEMG) muscle monitoring. No optimal trade-off, able to concurrently address several problems of the acquisition system like robustness, miniaturization, versatility, and power efficiency, has yet been found. In this tutorial we present a solution to most of these issues, embedding in a single device both an sEMG acquisition channel, with our custom event-driven hardware feature extraction technique (named Average Threshold Crossing), and a digital part, which includes a microcontroller unit, for (optionally) sEMG sampling and processing, and a Bluetooth communication, for wireless data transmission. The knowledge acquired by the research group brought to an accurate selection of each single component, resulting in a very efficient prototype, with a comfortable final size (57.8mm x 25.2mm x 22.1mm) and a consistent signal-to-noise ratio of the acquired sEMG (higher than 15 dB). Furthermore, a precise design of the firmware has been performed, handling both signal acquisition and Bluetooth transmission concurrently, thanks to a FreeRTOS custom implementation. In particular, the system adapts to both sEMG and ATC transmission, with an application throughput up to 2 kBs(-1) and an average operating time of 80 h (for high resolutions EMG sampling), relaxable to 8Bs(-1) throughput and about 230 h operating time (considering a 110 mAh battery), in case of ATC acquisition only. Here we share our experience over the years in designing wearable systems for the sEMG detection, specifying in detail how our event-driven approach could benefit the device development phases. Some previous basic knowledge about biosignal acquisition, electronic circuits and programming would certainly ease the repeatability of this tutorial.
引用
收藏
页码:22285 / 22303
页数:19
相关论文
共 81 条
[21]  
Crepaldi M, 2012, BIOMED CIRC SYST C, P116, DOI 10.1109/BioCAS.2012.6418406
[22]  
De Luca C.J., 2002, Surface Electromyography: Detection and Recording
[23]   Filtering the surface EMG signal: Movement artifact and baseline noise contamination [J].
De Luca, Carlo J. ;
Gilmore, L. Donald ;
Kuznetsov, Mikhail ;
Roy, Serge H. .
JOURNAL OF BIOMECHANICS, 2010, 43 (08) :1573-1579
[24]  
Delsys, DELSYS FAMILY PRODUC
[25]  
DeLuca G., 2001, FUNDAMENTAL CONCEPTS
[26]  
Digital Science & Research Solutions, SURF EL PUBL DIM
[27]   An Embedded, Eight Channel, Noise Canceling, Wireless, Wearable sEMG Data Acquisition System With Adaptive Muscle Contraction Detection [J].
Ergeneci, Mert ;
Gokcesu, Kaan ;
Ertan, Erhan ;
Kosmas, Panagiotis .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2018, 12 (01) :68-79
[28]  
Franco S., 2002, Design with Operational Amplifiers and Analog Integrated Circuits, V3rd
[29]   Real-Time Evaluation of the Signal Processing of sEMG Used in Limb Exoskeleton Rehabilitation System [J].
Gao, Baofeng ;
Wei, Chao ;
Ma, Hongdao ;
Yang, Shu ;
Ma, Xu ;
Zhang, Songyuan .
APPLIED BIONICS AND BIOMECHANICS, 2018, 2018
[30]  
Guzman DAF, 2017, BIOMED CIRC SYST C