Tutorial: A Versatile Bio-Inspired System for Processing and Transmission of Muscular Information

被引:12
作者
Rossi, Fabio [1 ]
Mongardi, Andrea [1 ]
Ros, Paolo Motto [1 ]
Roch, Massimo Ruo [1 ]
Martina, Maurizio [1 ]
Demarchi, Danilo [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, I-10129 Turin, Italy
关键词
Bio-inspired electronics; surface electromyography; bluetooth low energy; event-based; information synthesis; power efficiency; wearable system; WIRELESS; ACQUISITION;
D O I
10.1109/JSEN.2021.3103608
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Device wearability and operating time are trending topics in recent state-of-art works on surface ElectroMyoGraphic (sEMG) muscle monitoring. No optimal trade-off, able to concurrently address several problems of the acquisition system like robustness, miniaturization, versatility, and power efficiency, has yet been found. In this tutorial we present a solution to most of these issues, embedding in a single device both an sEMG acquisition channel, with our custom event-driven hardware feature extraction technique (named Average Threshold Crossing), and a digital part, which includes a microcontroller unit, for (optionally) sEMG sampling and processing, and a Bluetooth communication, for wireless data transmission. The knowledge acquired by the research group brought to an accurate selection of each single component, resulting in a very efficient prototype, with a comfortable final size (57.8mm x 25.2mm x 22.1mm) and a consistent signal-to-noise ratio of the acquired sEMG (higher than 15 dB). Furthermore, a precise design of the firmware has been performed, handling both signal acquisition and Bluetooth transmission concurrently, thanks to a FreeRTOS custom implementation. In particular, the system adapts to both sEMG and ATC transmission, with an application throughput up to 2 kBs(-1) and an average operating time of 80 h (for high resolutions EMG sampling), relaxable to 8Bs(-1) throughput and about 230 h operating time (considering a 110 mAh battery), in case of ATC acquisition only. Here we share our experience over the years in designing wearable systems for the sEMG detection, specifying in detail how our event-driven approach could benefit the device development phases. Some previous basic knowledge about biosignal acquisition, electronic circuits and programming would certainly ease the repeatability of this tutorial.
引用
收藏
页码:22285 / 22303
页数:19
相关论文
共 81 条
[11]   Design Considerations for Wireless Acquisition of Multichannel sEMG Signals in Prosthetic Hand Control [J].
Brunelli, Davide ;
Farella, Elisabetta ;
Giovanelli, Davide ;
Milosevic, Bojan ;
Minakov, Ivan .
IEEE SENSORS JOURNAL, 2016, 16 (23) :8338-8347
[12]  
Calado A, 2019, IEEE INT CONF AUTON, P276, DOI 10.1109/IRMMW-THz.2019.8873701
[13]   Surface EMG in Clinical Assessment and Neurorehabilitation: Barriers Limiting Its Use [J].
Campanini, Isabella ;
Disselhorst-Klug, Catherine ;
Rymer, William Z. ;
Merletti, Roberto .
FRONTIERS IN NEUROLOGY, 2020, 11
[14]  
Cardinal Health, KEND H124SG EL
[15]  
Cellevia Batteries, POLYM LITH ION BATT
[16]   A Modular, Smart, and Wearable System for High Density sEMG Detection [J].
Cerone, Giacinto Luigi ;
Botter, Alberto ;
Gazzoni, Marco .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (12) :3371-3380
[17]   A Wireless sEMG Recording System and Its Application to Muscle Fatigue Detection [J].
Chang, Kang-Ming ;
Liu, Shin-Hong ;
Wu, Xuan-Han .
SENSORS, 2012, 12 (01) :489-499
[18]  
Chen XB, 2017, IEEE ENG MED BIO, P382, DOI 10.1109/EMBC.2017.8036842
[19]  
Cometa Srl, COMETA SYSTEMS
[20]   The history of surface electromyography [J].
Cram, JR .
APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2003, 28 (02) :81-91