Comparative Analysis of 24-2C, 24-2, and 10-2 Visual Field Tests for Detecting Mild-Stage Glaucoma With Central Visual field Defects

被引:0
|
作者
Nishijima, Euido [1 ]
Fukai, Kota [2 ]
Sano, Kei [1 ]
Noro, Takahiko [1 ]
Ogawa, Shumpei [1 ]
Okude, Sachiyo
Tatemichi, Masayuki [2 ]
Lee, Gary c. [3 ]
Iwase, Aiko [4 ]
Nakano, Tadashi [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Ophthalmol, 3-25-8 Nishi Shimbashi,Minato Ku, Tokyo 1058461, Japan
[2] Tokai Univ, Dept Prevent Med, Sch Med, Isehara, Japan
[3] Carl Zeiss Meditec Inc, Dublin, CA USA
[4] Tajimi Iwase Eye Clin, Tajimi, Japan
基金
日本学术振兴会;
关键词
QUALITY-OF-LIFE; PREVALENCE; THRESHOLD; PROGRESSION; BLINDNESS; IMPACT; DAMAGE; GRIDS;
D O I
10.1016/j.ajo.2024.07.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: This study sought to identify the most effective testing program for detecting visual-field defects in mild-stage glaucoma with central visual-field defects. center dot DESIGN: A multicenter, retrospective diagnostic testing evaluation. center dot PARTICIPANTS: The study involved 93 eyes (83 patients) with mild-stage glaucoma (median mean deviation [interquartile range]:-1.79 [2.16] dB) with central visual-field defects and 69 eyes (63 patients; median mean deviation,-1.38 [2.31] dB) with mild-stage glaucoma without central visual-field defects, from Jikei University School of Medicine and Tajimi Iwase Eye Clinic. center dot METHODS: Patients underwent 10-2 Swedish Interactive Thresholding Algorithm (SITA) Standard, 24-2 SITA Standard, and 24-2C SITA Faster tests. Central visual-field defects were defined using 10-2 SITA Standard and optical coherence tomography (OCT). A detection power of 4 points in the 24-2 that coincided with 102 (Center4), 12 points that lie within 10 degrees (24-2-12), and 22 points that lie within 10 degrees of 24-2C (24-2C-22) were analyzed using receiver operating characteristic (ROC) curves based on logistic regression analysis, using total deviation (TD) and pattern deviation (PD) probability plots. center dot MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve (AUC) of the Center4, 242-12, and 24-2C-22 tests. center dot RESULTS: In the upper-central visual field, AUCs of the TD plot were 0.50 (0.40-0.58) for the Center4, 0.75 (0.67-0.83) for 24-2-12, and 0.85 (0.78-0.91) for 24 2C-22, with 24-2C-22 AUC significantly exceeding 242-12 AUC. For the PD plot, AUCs were 0.53 (0.440.63), 0.81 (0.74-0.89), and 0.84 (0.77-0.90), respectively. In the lower-central visual field, using a total plot, AUCs were 0.27 (0.18-0.36), 0.57 (0.47-0.69), and 0.57 (0.46-0.68) for the Center4, 24-2-12, and 24-2C22, respectively. Using the PD plot in the upper field, AUCs were 0.27 (0.19-0.36), 0.64 (0.53-0.75), and 0.81 (0.72-0.90), respectively, with the AUC of the 242C-22 significantly exceeding that of 24-2-12. The 242C test was significantly faster than both the 24-2 and 10-2 tests, reducing testing duration by 46% and 52%, respectively. center dot CONCLUSIONS: The 24-2C SITA Faster test is highly effective and efficient for detecting mild-stage glaucoma with central visual-field defects. This, and its reduced duration, makes it a valuable tool in clinical settings.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 46 条
  • [21] Relationships of Retinal Structure and Humphrey 24-2 Visual Field Thresholds in Patients With Glaucoma
    Bogunovic, Hrvoje
    Kwon, Young H.
    Rashid, Adnan
    Lee, Kyungmoo
    Critser, Douglas B.
    Garvin, Mona K.
    Sonka, Milan
    Abramoff, Michael D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (01) : 259 - 271
  • [22] Association Between Longitudinal 10-2 Central Visual Field Change and the Risk of Visual Acuity Loss in Mild-to-Moderate Glaucoma
    Wu, Jo-Hsuan
    Moghimi, Sasan
    Nishida, Takashi
    Kamalipour, Alireza
    Liebmann, Jeffrey M.
    Fazio, Massimo
    Girkin, Christopher A.
    Zangwill, Linda M.
    Weinreb, Robert N.
    JOURNAL OF GLAUCOMA, 2023, 32 (07) : 549 - 555
  • [23] Point-wise variability of threshold sensitivity of 24-2 and 10-2 visual fields
    Rao, Aparna
    Rao, Harsha
    Padhy, Debananda
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2022, 12 (02) : 170 - +
  • [24] Usefulness of 10-2 Matrix Frequency Doubling Technology Perimetry for Detecting Central Visual Field Defects in Preperimetric Glaucoma Patients
    Jung, Younhea
    Park, Hae-Young L.
    Park, Yi Ryeung
    Park, Chan Kee
    SCIENTIFIC REPORTS, 2017, 7
  • [25] Which glaucoma patients benefit from 10-2 visual field testing? Proposing the functional vulnerability zone framework
    Phu, Jack
    Rafla, Daniel
    Kalloniatis, Michael
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (02) : 171 - 183
  • [26] Importance of Pattern Standard Deviation of Humphrey 10-2 Visual Field to Evaluate Central Visual Function in Patients with Early-Stage Glaucoma
    Shin, Hee Jong
    Oh, Si Eun
    Park, Chan Kee
    Park, Hae-Young Lopilly
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (15)
  • [27] Baseline 10-2 Visual Field Loss as a Predictor for Future Glaucoma Progression
    Sullivan-Mee, Michael
    Kimura, Bryan
    Kee, Helen
    Hedayat, Mahdi
    Charry, Nicole
    Katiyar, Suchitra
    Pensyl, Denise
    Qualls, Clifford
    JOURNAL OF GLAUCOMA, 2023, 32 (01) : 1 - 8
  • [28] Studying the role of 10-2 visual field test in different stages of glaucoma
    Tomairek, Reham Hosny
    Aboud, Safaa Awadallah
    Hassan, Mansour
    Mohamed, Alyaa H.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (04) : 706 - 713
  • [29] Real-World Analysis of the Aging Effects on Visual Field Reliability Indices in Central 10-2 Tests
    Shirakami, Tomoki
    Omura, Tetsuro
    Fukuda, Hiroki
    Asaoka, Ryo
    Tanito, Masaki
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (10):
  • [30] Optical Coherence Tomography Analysis Based Prediction of Humphrey 24-2 Visual Field Thresholds in Patients With Glaucoma
    Guo, Zhihui
    Kwon, Young H.
    Lee, Kyungmoo
    Wang, Kai
    Wahle, Andreas
    Alward, Wallace L. M.
    Fingert, John H.
    Bettis, Daniel I.
    Johnson, Chris A.
    Garvin, Mona K.
    Sonka, Milan
    Abramoff, Michael D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (10) : 3975 - 3985