A blood pressure estimation approach based on single-channel differential features

被引:1
|
作者
Chen, Qin [1 ,2 ]
Yang, Xuezhi [1 ,2 ,3 ]
Chen, Yawei [1 ,2 ]
Han, Xuesong [1 ,2 ]
Gong, Zheng [1 ,2 ]
Wang, Dingliang [4 ]
Zhang, Jie [5 ]
机构
[1] Hefei Univ Technol, Sch Comp & Informat, Hefei 230601, Peoples R China
[2] Anhui Prov key Lab Ind Safety & Emergency Technol, Hefei 230601, Peoples R China
[3] Intelligent Interconnected Syst Lab Anhui Prov, Hefei 230009, Peoples R China
[4] Anhui Univ, Dept Elect Sci & Technol, Hefei 230601, Peoples R China
[5] Univ Sci & Technol China, Affiliated Hosp 1, Dept Cardiol, Hefei 230036, Peoples R China
关键词
Blood pressure; Photoplethysmography; PPG differential feature; Feature selection; Blood pressure variation; PULSE ARRIVAL-TIME; PHOTOPLETHYSMOGRAPHY; SIGNAL;
D O I
10.1016/j.bspc.2024.106662
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Effective blood pressure (BP) management is crucial for early cardiovascular disease treatment. Photoplethysmography (PPG) waveform analysis presents a promising avenue for non-invasive BP estimation. However, existing methods often overlook the impact of PPG feature changes on BP variations, and the effectiveness and physiological interpretability of the features they employ remain largely unclear. Hence, this work introduces a single-channel BP estimation algorithm founded on the PPG differential features (DFs). Methods: A three-month tracking of PPG and BP data was conducted on 90 volunteers, and 68 blood pressurerelated features were extracted from their PPG. The features in the first measurement data were used as baseline features. The differential features were obtained by subtracting the baseline features from the features in the subsequent measurement data through differential feature processing, and 11 DFs for BP estimation were retained using feature selection. Subsequently, four machine learning models were applied for the estimation of systolic (SBP) and diastolic blood pressure (DBP) changes, and finally introduced baseline blood pressure values to achieve BP estimation. Results: Investigating the correlation between PPG DFs and BP changes, we observed a more significant correlation with BP changes for PPG DFs compared to PPG features. Among the machine learning models, the Random Forest model exhibited the most accurate estimation results in blood pressure, achieving standard deviation of the error(STD) of 7.15 mmHg for SBP and 5.30 mmHg for DBP, along with Pearson correlation coefficients (PCC) of 0.90 and 0.86, respectively. Conclusion: This work demonstrates that incorporating PPG feature changes with BP changes achieves higher accuracy in BP estimation, confirming the effectiveness of PPG DFs in BP estimation and providing valuable insights for long-term non-invasive blood pressure monitoring.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Single-channel Head Orientation Estimation Based on Discrimination of Acoustic Transfer Function
    Takashima, Ryoichi
    Takiguchi, Tetsuya
    Ariki, Yasuo
    12TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION 2011 (INTERSPEECH 2011), VOLS 1-5, 2011, : 2732 - 2735
  • [22] Single-Channel Mixed Signal Detection Based on Signal Noise Ratio Estimation
    Fu, Jun
    Huan, Qiang
    Peng, Hua
    PROCEEDINGS OF 2017 IEEE 2ND INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC), 2017, : 705 - 711
  • [23] SINGLE-CHANNEL SPEAKER DISTANCE ESTIMATION IN REVERBERANT ENVIRONMENTS
    Neri, Michael
    Politis, Archontis
    Krause, Daniel
    Carli, Marco
    Virtanen, Tuomas
    2023 IEEE WORKSHOP ON APPLICATIONS OF SIGNAL PROCESSING TO AUDIO AND ACOUSTICS, WASPAA, 2023,
  • [24] Estimation of Source Number for Single-Channel Received Signal
    Zuo, Zhen
    Hu, Jun Peng
    Huang, Zhi Ping
    Zhang, Yi Meng
    2016 INTERNATIONAL CONFERENCE ON ELECTRONIC, INFORMATION AND COMPUTER ENGINEERING, 2016, 44
  • [25] Assessment of Single-channel Ego Noise Estimation Methods
    Ince, Goekhan
    Nakadai, Kazuhiro
    Rodemann, Tobias
    Imura, Jun-ichi
    Nakamura, Keisuke
    Nakajima, Hirofumi
    2011 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, 2011, : 106 - 111
  • [27] Classification of single-channel EEG signals for epileptic seizures detection based on hybrid features
    Lu, Yanan
    Ma, Yu
    Chen, Chen
    Wang, Yuanyuan
    TECHNOLOGY AND HEALTH CARE, 2018, 26 : S337 - S346
  • [28] Estimation of single-channel EEG features with auditory cognitive assessment in early detection of Parkinson's disease
    Gurevich, Tanya
    Intrator, Nathan
    Zeimer, Talya
    Hezi, Neomi
    Maimon, Neta B.
    Molcho, Lior
    MOVEMENT DISORDERS, 2023, 38 : S8 - S9
  • [29] Performance of epileptic single-channel scalp EEG classifications using single wavelet-based features
    Janjarasjitt, Suparerk
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 57 - 67
  • [30] Performance of epileptic single-channel scalp EEG classifications using single wavelet-based features
    Suparerk Janjarasjitt
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 57 - 67