A blood pressure estimation approach based on single-channel differential features

被引:1
|
作者
Chen, Qin [1 ,2 ]
Yang, Xuezhi [1 ,2 ,3 ]
Chen, Yawei [1 ,2 ]
Han, Xuesong [1 ,2 ]
Gong, Zheng [1 ,2 ]
Wang, Dingliang [4 ]
Zhang, Jie [5 ]
机构
[1] Hefei Univ Technol, Sch Comp & Informat, Hefei 230601, Peoples R China
[2] Anhui Prov key Lab Ind Safety & Emergency Technol, Hefei 230601, Peoples R China
[3] Intelligent Interconnected Syst Lab Anhui Prov, Hefei 230009, Peoples R China
[4] Anhui Univ, Dept Elect Sci & Technol, Hefei 230601, Peoples R China
[5] Univ Sci & Technol China, Affiliated Hosp 1, Dept Cardiol, Hefei 230036, Peoples R China
关键词
Blood pressure; Photoplethysmography; PPG differential feature; Feature selection; Blood pressure variation; PULSE ARRIVAL-TIME; PHOTOPLETHYSMOGRAPHY; SIGNAL;
D O I
10.1016/j.bspc.2024.106662
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Effective blood pressure (BP) management is crucial for early cardiovascular disease treatment. Photoplethysmography (PPG) waveform analysis presents a promising avenue for non-invasive BP estimation. However, existing methods often overlook the impact of PPG feature changes on BP variations, and the effectiveness and physiological interpretability of the features they employ remain largely unclear. Hence, this work introduces a single-channel BP estimation algorithm founded on the PPG differential features (DFs). Methods: A three-month tracking of PPG and BP data was conducted on 90 volunteers, and 68 blood pressurerelated features were extracted from their PPG. The features in the first measurement data were used as baseline features. The differential features were obtained by subtracting the baseline features from the features in the subsequent measurement data through differential feature processing, and 11 DFs for BP estimation were retained using feature selection. Subsequently, four machine learning models were applied for the estimation of systolic (SBP) and diastolic blood pressure (DBP) changes, and finally introduced baseline blood pressure values to achieve BP estimation. Results: Investigating the correlation between PPG DFs and BP changes, we observed a more significant correlation with BP changes for PPG DFs compared to PPG features. Among the machine learning models, the Random Forest model exhibited the most accurate estimation results in blood pressure, achieving standard deviation of the error(STD) of 7.15 mmHg for SBP and 5.30 mmHg for DBP, along with Pearson correlation coefficients (PCC) of 0.90 and 0.86, respectively. Conclusion: This work demonstrates that incorporating PPG feature changes with BP changes achieves higher accuracy in BP estimation, confirming the effectiveness of PPG DFs in BP estimation and providing valuable insights for long-term non-invasive blood pressure monitoring.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A novel method for continuous blood pressure estimation based on a single-channel photoplethysmogram signal
    Hu, Qihan
    Deng, Xintao
    Wang, Aiguo
    Yang, Cuiwei
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (12)
  • [2] SINGLE-CHANNEL SPEAKER DIARIZATION BASED ON SPATIAL FEATURES
    Hu, Mathieu
    Parada, Pablo Peso
    Sharma, Dushyant
    Doclo, Simon
    van Waterschoot, Toon
    Brookes, Mike
    Naylor, Patrick A.
    2015 IEEE WORKSHOP ON APPLICATIONS OF SIGNAL PROCESSING TO AUDIO AND ACOUSTICS (WASPAA), 2015,
  • [3] A Refined Blood Pressure Estimation Model Based on Single Channel Photoplethysmography
    Zhang, Yiming
    Ren, Xianglin
    Liang, Xiao
    Ye, Xuesong
    Zhou, Congcong
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (12) : 5907 - 5917
  • [4] Single-Channel Bioimpedance Measurement for Wearable Continuous Blood Pressure Monitoring
    Wang, Ting-Wei
    Chen, Wen-Xiang
    Chu, Hsiao-Wei
    Lin, Shien-Fong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [5] SINGLE-CHANNEL PRESSURE TELEMETRY UNIT
    SANDLER, H
    FRYER, TB
    DATNOW, B
    JOURNAL OF APPLIED PHYSIOLOGY, 1969, 26 (02) : 235 - &
  • [6] SINGLE-CHANNEL DIFFERENTIAL DISCRIMINATOR FOR SCINTILLATION SPECTROMETER
    ASTROM, B
    ARKIV FOR FYSIK, 1952, 5 (1-2): : 112 - 112
  • [7] Accuracy of a cuffless blood pressure measurement with a single-channel electrocardiogram monitor with photoplethysmography
    Sagirova, Z. H. N.
    Kuznetsova, N. O.
    Gogiberidze, N. A.
    Gognieva, D. G.
    Chomakhidze, P. S. H.
    Kopylov, P. H. Y. U.
    EUROPEAN HEART JOURNAL, 2021, 42 : 2346 - 2346
  • [8] Microphone utility estimation in acoustic sensor networks using single-channel signal features
    Guenther, Michael
    Brendel, Andreas
    Kellermann, Walter
    EURASIP JOURNAL ON AUDIO SPEECH AND MUSIC PROCESSING, 2023, 2023 (01)
  • [9] Microphone utility estimation in acoustic sensor networks using single-channel signal features
    Michael Günther
    Andreas Brendel
    Walter Kellermann
    EURASIP Journal on Audio, Speech, and Music Processing, 2023
  • [10] Single-channel Blind Source Separation Based on Cyclic Spectrum Estimation
    He, Jiai
    Liu, Linzhi
    2013 6TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), VOLS 1-3, 2013, : 1525 - 1529