Impact of Net Atrioventricular Compliance on Mitral Valve Area Assessment-A Perspective Considering Three-Dimensional Mitral Valve Area by Transesophageal Echocardiography

被引:0
作者
Li, Tony [1 ]
Leow, Ryan [1 ]
Chan, Meei Wah [1 ]
Kong, William K. F. [1 ,2 ]
Kuntjoro, Ivandito [1 ,2 ]
Poh, Kian Keong [1 ,2 ]
Sia, Ching Hui [1 ,2 ]
Yeo, Tiong Cheng [1 ,2 ]
机构
[1] Natl Univ Heart Ctr Singapore, Dept Cardiol, 1E Kent Ridge Rd,Tower Block Level 9, Singapore 119228, Singapore
[2] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Med, Singapore 117597, Singapore
基金
英国医学研究理事会;
关键词
mitral stenosis; rheumatic heart disease; pressure half-time; net atrioventricular compliance; PRESSURE HALF-TIME; DOPPLER-ECHOCARDIOGRAPHY; CONTINUITY EQUATION; STENOSIS; DISEASE;
D O I
10.3390/diagnostics14151595
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Net atrioventricular compliance (Cn) can affect the accuracy of mitral valve area (MVA) assessment. We assessed how different methods of MVA assessment are affected by Cn, and if patients with abnormal Cn may be identified by clinical and/or echocardiographic parameters. Methods: We studied 244 patients with rheumatic MS. The concordance between mitral valve area (MVA) by 2D planimetry, pressure half-time (PHT), continuity equation (CE), Yeo's index, and 3-dimensional mitral valve area assessed by transesophageal echocardiography (TEE 3DMVA) in patients with normal and abnormal Cn (Cn <= 4 mL/mmHg) were evaluated in the 110 patients with both transesophageal echocardiogram (TEE) and transthoracic echocardiogram (TTE). Variables that were associated with abnormal Cn were validated in the remaining 134 patients with only TTE. Results: Except for MVA by CE, concordance with TEE 3DMVA was poorer for all other methods of MVA assessment in patients with abnormal Cn. But, the difference in concordance was only statistically significant for MVA by PHT. Patients with MVA <= 1.5 cm2 by 2D planimetry and PHT <= 130 ms were likely to have an abnormal Cn. (specificity 98.5%). This finding was validated in the remaining 134 patients (specificity 93%). Conclusions: MVA assessment by PHT is significantly affected by Cn. Abnormal Cn should be suspected when 2D planimetry MVA is <= 1.5 cm2 together with an inappropriately short PHT that is <= 130 ms. In this scenario, MVA by PHT is inaccurate.
引用
收藏
页数:9
相关论文
共 29 条
  • [1] Abascal VM, 1996, AM J CARDIOL, V78, P1390
  • [2] Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice
    Baumgartner, Helmut
    Hung, Judy
    Bermejo, Javier
    Chambers, John B.
    Evangelista, Arturo
    Griffin, Brian P.
    Iung, Bernard
    Otto, Catherine M.
    Pellikka, Patricia A.
    Quinones, Miguel
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) : 1 - 23
  • [3] Improved assessment of mitral valve stenosis by volumetric real-time three-dimensional echocardiography
    Binder, TM
    Rosenhek, R
    Porenta, G
    Maurer, G
    Baumgartner, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) : 1355 - 1361
  • [4] DOPPLER ECHOCARDIOGRAPHIC ESTIMATION OF MITRAL-VALVE AREA DURING CHANGING HEMODYNAMIC CONDITIONS
    BRAVERMAN, AC
    THOMAS, JD
    LEE, RT
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (15) : 1485 - 1490
  • [5] Mitral stenosis
    Chandrashekhar, Y.
    Westaby, Stephen
    Narula, Jagat
    [J]. LANCET, 2009, 374 (9697) : 1271 - 1283
  • [6] Measurement of mitral valve area in mitral stenosis: Four echocardiographic methods compared with direct measurement of anatomic orifices
    Faletra, F
    Pezzano, A
    Fusco, R
    Mantero, A
    Corno, R
    Crivellaro, W
    DeChiara, F
    Vitali, E
    Gordini, V
    Magnani, P
    Pezzano, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) : 1190 - 1197
  • [7] CALCULATION OF ATRIOVENTRICULAR COMPLIANCE FROM THE MITRAL FLOW PROFILE - ANALYTIC AND INVITRO STUDY
    FLACHSKAMPF, FA
    WEYMAN, AE
    GUERRERO, JL
    THOMAS, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (05) : 998 - 1004
  • [8] A STUDY OF THE CORRELATION BETWEEN DOPPLER AND CROSS-SECTIONAL ECHOCARDIOGRAPHY IN THE DETERMINATION OF THE MITRAL-VALVE AREA
    FRIART, A
    VANDENBOSSCHE, JL
    KOSTUCKI, W
    ENGLERT, M
    [J]. EUROPEAN HEART JOURNAL, 1987, 8 (05) : 484 - 489
  • [9] NON-INVASIVE ASSESSMENT OF ATRIOVENTRICULAR PRESSURE HALF-TIME BY DOPPLER ULTRASOUND
    HATLE, L
    ANGELSEN, B
    TROMSDAL, A
    [J]. CIRCULATION, 1979, 60 (05) : 1096 - 1104
  • [10] Impact of Cardiac Rhythm on Mitral Valve Area Calculated by the Pressure Half Time Method in Patients With Moderate or Severe Mitral Stenosis
    Kim, Hyung-Kwan
    Kim, Yong-Jin
    Chang, Sung-A
    Kim, Dae-Hee
    Sohn, Dae-Won
    Oh, Byung-Hee
    Park, Young-Bae
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) : 42 - 47