Assessment of Current Analysis Methodology of Light-Frame Wood Buildings Under Lateral Loads Using Wood3D

被引:0
作者
Risha, Aya [1 ]
Enajar, Adnan [1 ]
El Damatty, Ashraf [1 ,2 ]
机构
[1] Western Univ, Dept Civil & Environm Engn, London, ON, Canada
[2] Western Univ, WindEEE Res Inst, London, ON, Canada
来源
PROCEEDINGS OF THE CANADIAN SOCIETY OF CIVIL ENGINEERING ANNUAL CONFERENCE 2022, VOL 3, CSCE 2022 | 2024年 / 359卷
关键词
Light-frame wood buildings; Finite element analysis; Nonlinear link elements; Wood3D; 3-DIMENSIONAL MODEL;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wood shear walls are the main components used to resist lateral loads in a light-frame wood building (LFWB). In a previous study, a novel simplified model, that accurately predicts the deformations and the straining actions in the shear walls of a LFWB through three-dimensional finite element analysis, was developed. This efficient model implicitly simulated all the components of the shear walls including the sheathings, the studs, and the nails. In this model, the bending and the shear stiffness of the walls are simulated using nonlinear link elements. An extensive database was developed to determine the link properties for all the work configurations. An interface was also developed that is integrated with the commercial software ETABS and the database, allowing an efficient three-dimensional analysis of LFWBs under lateral loads. This numerical package is named "Wood3D". The softwareWood3D can estimate the straining actions in all the components of aLFWB under the combined effects of gravity and lateral loads. In the current study, Wood3D is used to analyze and conduct a design check for an existing LFWS that was designed using the approximate procedure, currently employed in the industry. The results are used to assess the accuracy of this approximate procedure in comparison with the rigorous analysis and design checks conducted using Wood3D. Three models of the existing LFWB are generated using different modeling assumptions. The results from this analysis conclude that the current design method for wood shear walls in the industry is over-conservative.
引用
收藏
页码:283 / 298
页数:16
相关论文
共 12 条
  • [1] Canadian Wood Council and Canadian Standards Association, 2020, Wood design manual
  • [2] Proposal of an analytical procedure and a simplified numerical model for elastic response of single-storey timber shear-walls
    Casagrande, Daniele
    Rossi, Simone
    Sartori, Tiziano
    Tomasi, Roberto
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 102 : 1101 - 1112
  • [3] Chen Z, 2014, WCTE 2014, P1
  • [4] Three-dimensional model of light frame wood buildings. I: Model description
    Collins, M
    Kasal, B
    Paevere, P
    Foliente, GC
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2005, 131 (04): : 676 - 683
  • [5] Three-dimensional model of light frame wood buildings. II: Experimental investigation and validation of analytical model
    Collins, M
    Kasal, B
    Paevere, P
    Foliente, GC
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (04) : 684 - 692
  • [6] CSA, 2019, CSA O86:19 (R2019)
  • [7] Hysteretic damping of wood framed buildings
    Filiatrault, A
    Isoda, H
    Folz, B
    [J]. ENGINEERING STRUCTURES, 2003, 25 (04) : 461 - 471
  • [8] Kuzman MK, 2017, 2 LAT AM C TIMB STRU, P1
  • [9] Seismic performance of post and beam timber buildings I: model development and verification
    Li, Minghao
    Lam, Frank
    Foschi, Ricardo O.
    Nakajima, Shiro
    Nakagawa, Takafumi
    [J]. JOURNAL OF WOOD SCIENCE, 2012, 58 (01) : 20 - 30
  • [10] Numerical assessment of lateral deflection equation of single-storey light-frame wood shear walls
    Niazi, Mohammad
    El Damatty, Ashraf A.
    Hamada, Ahmed
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 2021, 48 (12) : 1663 - 1673