Ceramic-on-Ceramic Total Hip Arthroplasty Using a Double Tapered, Proximally Coated Stem: 15 to 24-year Clinical and Radiologic Follow-Up

被引:0
作者
Darwish, Mohammad M. [1 ]
Bergman, Neil R. [1 ]
Hiscock, Richard J. [1 ]
机构
[1] Warringal Med Ctr, 214 Burgundy St, Heidelberg, Vic 3084, Australia
关键词
total hip arthroplasty; hip arthroplasty; ceramic; cementless; alumina-on-alumina; long term; ACETABULAR COMPONENT; SQUEAKING; ALUMINA; SOCKETS; POLYETHYLENE; IMPINGEMENT; OSTEOLYSIS;
D O I
10.1016/j.arth.2024.04.051
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total hip arthroplasty implant choice profoundly affects survivorship, complications, and failure modes. This study evaluates the long-term (average 18 year) outcomes of ceramic-on-ceramic hip arthroplasty using uncemented shells and stems. Despite an impressive 20-year cumulative percent revision of 5.9%, the hydroxyapatite proximally coated femoral components evaluated in this study have seen declining use since 2003. Methods: A review of 349 consecutive total hip arthroplasties from 1999 to 2007 was matched to 272 cases with registry data. A survivorship analysis included 274 hips (Group A) after excluding patients lost to follow-up and navigated cases. Group B comprised 135 patients who had complete datasets spanning a minimum of 15 years. Results: Kaplan-Meier analysis identified a 95.6% survivorship plateau at 16 to 24 years, with no significant impact from age, sex, component size, or original pathology. In Group B, EuroQol-5 Dimensions-5 Levels (EQ5D5L) scores indicated favorable outcomes in mobility, self-care, activities, pain/discomfort, and anxiety/depression, with an EQ5D visual analog score mean of 79.24. Functional scores, including the Harris Hip Score, Oxford Hip Score, and Forgotten Joint Score, showed positive outcomes. Radiologic assessments revealed no osteolysis or loose components, with a mean Engh score of 21.69. Dorr classification identified bone quality variations. Better Engh scores corresponded to higher levels of patient satisfaction. Age at surgery was correlated with better functional scores, while sex influenced various outcomes. Conclusions: This comprehensive study, spanning an average of 18.23 years, combined multiple patient- reported outcome measures with extensive clinical and radiologic follow-up. It reported a notably high survivorship rate for this implant combination but highlighted the declining use of the hydroxyapatite proximally coated femoral stem used in this study, potentially facing withdrawal risks in Australia. Level of evidence: Therapeutic Level IV. (c) 2024 Elsevier Inc. All rights reserved.
引用
收藏
页码:2323 / 2328
页数:6
相关论文
共 35 条
[21]  
Khumrak S., 2012, The Bangkok Medical Journal, V4, P93, DOI [10.31524/bkkmedj.2012.09.015, DOI 10.31524/BKKMEDJ.2012.09.015]
[22]   Long-Term Results of Third-Generation Ceramic-on-Ceramic Bearing Cementless Total Hip Arthroplasty in Young Patients [J].
Kim, Young-Hoo ;
Park, Jang-Won ;
Kim, Jun-Shik .
JOURNAL OF ARTHROPLASTY, 2016, 31 (11) :2520-2524
[23]   Incidence of Ceramic Liner Malseating in TridentA® Acetabular Shell [J].
Miller, Anna N. ;
Su, Edwin P. ;
Bostrom, Mathias P. G. ;
Nestor, Bryan J. ;
Padgett, Douglas E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (06) :1552-1556
[24]   Computer Navigation vs Conventional Total Hip Arthroplasty: A Medicare Database Analysis [J].
Montgomery, Blake K. ;
Bala, Abiram ;
Huddleston, James I., III ;
Goodman, Stuart B. ;
Maloney, William J. ;
Amanatullah, Derek F. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (09) :1994-+
[25]  
Murali Rajmohan, 2008, J Arthroplasty, V23, DOI 10.1016/j.arth.2007.10.020
[26]   Functional orientation of the acetabular component in ceramic-on-ceramic total hip arthroplasty and its relevance to squeaking [J].
Pierrepont, J. W. ;
Feyen, H. ;
Miles, B. P. ;
Young, D. A. ;
Bare, J. V. ;
Shimmin, A. J. .
BONE & JOINT JOURNAL, 2016, 98B (07) :910-916
[27]   The noisy ceramic hip: Is component malpositioning the cause? [J].
Restrepo, Camilo ;
Parvizi, Javad ;
Kurtz, Steve M. ;
Sharkey, Peter F. ;
Hozack, William J. ;
Rothman, Richard H. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (05) :643-649
[28]   The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements [J].
Sexton, S. A. ;
Yeung, E. ;
Jackson, M. P. ;
Rajaratnam, S. ;
Martell, J. M. ;
Walter, W. L. ;
Zicat, B. A. ;
Walter, W. K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (04) :439-442
[29]  
socratesortho, Standardised Orthopaedic Clinical Research and Treatment Evaluation Software. 360 Med Care
[30]   Sex and Gender-Related Differences in the Outcome of Total Hip Arthroplasty: A Current Concepts Review [J].
Solarino, Giuseppe ;
Bizzoca, Davide ;
Moretti, Anna Maria ;
D'Apolito, Rocco ;
Moretti, Biagio ;
Zagra, Luigi .
MEDICINA-LITHUANIA, 2022, 58 (12)