Experimental Investigation of R404A Indirect Refrigeration System Applied Internal Heat Exchanger: Part 1-Coefficient of Performance Characteristics

被引:1
作者
Jeon, Min-Ju [1 ]
Lee, Joon-Hyuk [1 ]
机构
[1] Pukyong Natl Univ, Coll Engn, Dept Refrigerat & Air Conditioning Engn, 45 Yongso Ro, Busan 48513, South Korea
关键词
carbon dioxide; R744; R404A; coefficient of performance (COP); indirect refrigeration system (IRS); internal heat exchanger (IHX); ENERGY; CO2;
D O I
10.3390/en17164127
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, the performance characteristics of an R404A indirect refrigeration system (IRS) applied to an internal heat exchanger (IHX) is evaluated for supermarkets and hypermarkets. In a direct expansion system, R404A is the primary refrigerant and R744, a brine, is the secondary fluid. While there are abundant studies analyzing the theoretical performance of IRS, experimental research on IRS is lacking, and there are no papers that address the results of changes in the IHX in detail. In this study, the results achieved by modifying various parameters are experimentally evaluated to provide fundamental data for designing the optimal IRS. In the main results, looking at the trend of the increase in IHX efficiency, the change is very minimal when the efficiency is above 50%, so it is ideal to apply an IHX efficiency of about 50% considering economics and COP, etc. Applying the results in this study enables the operation and maintenance of IRSs as an eco-friendly system by achieving energy efficiency through optimizing the system coefficient of performance and securing economic feasibility by minimizing the R404A charging amount of the refrigeration cycle. To serve supermarkets and hypermarkets, R744 as a secondary fluid may help to realize an ecologically friendly, compact IRS system with a high heat transfer coefficient that can operate at low temperatures (-35 to 5 degrees C).
引用
收藏
页数:16
相关论文
共 48 条
  • [1] [Anonymous], 2008, US
  • [2] Arias J., 2005, ENERGY USAGE SUPERMA
  • [3] A comparative study on the environmental impact of supermarket refrigeration systems using low GWP refrigerants
    Beshr, M.
    Aute, V.
    Sharma, V.
    Abdelaziz, O.
    Fricke, B.
    Radermacher, R.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 56 : 154 - 164
  • [4] Review of alternative cooling technologies
    Brown, J. Steven
    Domanski, Piotr A.
    [J]. APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 252 - 262
  • [5] Burri R., 1999, P CENT C BRIT I REFR
  • [6] Review: Recent advances in household refrigerator cycle technologies
    Choi, Seyoung
    Han, Ukmin
    Cho, Honghyun
    Lee, Hoseong
    [J]. APPLIED THERMAL ENGINEERING, 2018, 132 : 560 - 574
  • [7] Clodic D., 1998, P INT REFR AIR COND
  • [8] Eggen G, 1998, REFR SCI T, V1998, P281
  • [9] Faramarzi RaminT., 2004, Investigation of Secondary Loop Supermarket Refrigeration Systems
  • [10] Theoretical evaluation of supermarket refrigeration systems using R1234ze(E) as an alternative to high-global warming potential refrigerants
    Gullo, Paride
    Cortella, Giovanni
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (08) : 1145 - 1155