Impact of motion management strategies on abdominal organ at risk delineation for magnetic resonance-guided radiotherapy

被引:2
作者
Daly, Mairead [1 ]
McDaid, Lisa [2 ]
Anandadas, Carmel [3 ]
Brocklehurst, Andrew [3 ]
Choudhury, Ananya [1 ,3 ]
McWilliam, Alan [1 ,4 ]
Radhakrishna, Ganesh [1 ,3 ]
Eccles, Cynthia L. [1 ,2 ]
机构
[1] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester M13 9PL, England
[2] Christie NHS Fdn Trust, Dept Radiotherapy, Manchester M20 4BX, England
[3] Christie Hosp NHS Fdn Trust, Dept Clin Oncol, Manchester M20 4BX, England
[4] Christie Hosp NHS Fdn Trust, Dept Med Phys & Engn, Manchester M20 4BX, England
关键词
Motion management; MR-guided radiotherapy; SABR; SBRT; IGRT; INTEROBSERVER VARIABILITY; VOLUME DELINEATION; MRI; SEGMENTATION; CANCER;
D O I
10.1016/j.phro.2024.100650
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The impact of respiratory motion management strategies for abdominal radiotherapy, such as abdominal compression (AC) and breath hold (BH), on abdominal organ at risk (OAR) delineation on magnetic resonance imaging (MRI) is unknown. This feasibility study compared the inter- and intra- observer delineation variation on MRI acquired with AC, BH for three critical abdominal OAR. Materials and methods: T2-weighted (W) 3D MRI in free-breathing (FB) and with AC, and T1W 3D mDixon exhale BH were acquired. Four observers blinded to motion management strategy used, delineated stomach, liver, and duodenum on all MRI. One case per strategy was repeated over 6 weeks later to quantify intra-observer variation. Simultaneous truth and performance level estimation (STAPLE) contours for each OAR were generated, median and IQR mean distance to agreement (mDTA) and maximum Hausdorff distance (HD) between observer and STAPLE contours were calculated. Observers scored organ visibility on each MRI using a four-point Likert scale. Results: A total of 27 scans including repeats were delineated. Pooled mDTA for all OARs was 1.3 mm (0.5 mm) with AC, 1.4 mm (1.0 mm) with BH, and 1.3 mm (0.5 mm) in FB. Intra-observer mDTA was highest for all organs in FB with 10.8 mm for duodenum, 1.8 mm for liver, and 2.7 mm for stomach. The pooled mean perceptual quality score value was highest for AC across organs. Conclusions: No motion management strategy demonstrated superior similarity across OAR, emphasizing the need for personalised approaches based on individual clinical and patient factors.
引用
收藏
页数:6
相关论文
共 35 条
[1]   A Comparison of Isotoxic Dose-escalated Radiotherapy in Lung Cancer with Moderate Deep Inspiration Breath Hold, Mid-ventilation and Internal Target Volume Techniques [J].
Bainbridge, H. ;
Dunlop, A. ;
McQuaid, D. ;
Gulliford, S. ;
Gunapala, R. ;
Ahmed, M. ;
Locke, I ;
Nill, S. ;
Oelfke, U. ;
McDonald, F. .
CLINICAL ONCOLOGY, 2022, 34 (03) :151-159
[2]   Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology [J].
Brandner, Edward D. ;
Chetty, Indrin J. ;
Giaddui, Tawfik G. ;
Xiao, Ying ;
Huq, M. Saiful .
MEDICAL PHYSICS, 2017, 44 (06) :2595-2612
[3]   Adoption of respiratory motion management in radiation therapy [J].
Burton, Alex ;
Beveridge, Sabeena ;
Hardcastle, Nicholas ;
Lye, Jessica ;
Sanagou, Masoumeh ;
Franich, Rick .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 24 :21-29
[4]  
Cancer Research UK, 2023, What Is Radiotherapy?
[5]   Inter-observer variability of clinical target volume delineation in radiotherapy treatment of pancreatic cancer: a multi-institutional contouring experience [J].
Caravatta, Luciana ;
Macchia, Gabriella ;
Mattiucci, Gian Carlo ;
Sainato, Aldo ;
Cernusco, Nunzia L. V. ;
Mantello, Giovanna ;
Di Tommaso, Monica ;
Trignani, Marianna ;
De Paoli, Antonino ;
Boz, Gianni ;
Friso, Maria L. ;
Fusco, Vincenzo ;
Di Nicola, Marta ;
Morganti, Alessio G. ;
Genovesi, Domenico .
RADIATION ONCOLOGY, 2014, 9
[6]   The Value of Magnetic Resonance Imaging for Radiotherapy Planning [J].
Dirix, Piet ;
Haustermans, Karin ;
Vandecaveye, Vincent .
SEMINARS IN RADIATION ONCOLOGY, 2014, 24 (03) :151-159
[7]   Artificial Intelligence in radiotherapy: state of the art and future directions [J].
Francolini, Giulio ;
Desideri, Isacco ;
Stocchi, Giulia ;
Salvestrini, Viola ;
Ciccone, Lucia Pia ;
Garlatti, Pietro ;
Loi, Mauro ;
Livi, Lorenzo .
MEDICAL ONCOLOGY, 2020, 37 (06)
[8]   Respiratory Gating Techniques for Optimization of Lung Cancer Radiotherapy [J].
Giraud, Philippe ;
Morvan, Esra ;
Claude, Line ;
Mornex, Francoise ;
Le Pechoux, Cecile ;
Bachaud, Jean-Marc ;
Boisselier, Pierre ;
Beckendorf, Veronique ;
Morelle, Magali ;
Carrere, Marie-Odile .
JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (12) :2058-2068
[9]   Stereotactic Body Radiation Therapy for Pancreatic Cancer [J].
Goodman, Karyn A. .
CANCER JOURNAL, 2016, 22 (04) :290-295
[10]   Feasibility of online radial magnetic resonance imaging for adaptive radiotherapy of pancreatic tumors [J].
Grimbergen, Guus ;
Eijkelenkamp, Hidde ;
van Vulpen, Jonna K. ;
van de Ven, Saskia ;
Raaymakers, Bas W. ;
Intven, Martijn P. W. ;
Meijer, Gert J. .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26