Design and Test of an Intraoral Electrode Grid for Tongue High-Density Electromyography

被引:0
|
作者
Botter, Alberto [1 ,2 ]
Vieira, Taian [1 ,2 ]
Busso, Chiara [3 ]
Vitali, Federica [1 ,2 ]
Gazzoni, Marco [1 ,2 ]
Cerone, Giacinto L. [1 ,2 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, Lab Engn Neuromuscular Syst LISiN, I-10129 Turin, Italy
[2] Politecn Torino, Polito BIOMed Lab, I-10129 Turin, Italy
[3] Univ Turin, Dept Surg Sci, Div Phys Med & Rehabil, I-10124 Turin, Italy
关键词
Electrode technology; electromyography; motor unit; decomposition; speech; tongue muscles; BIOMECHANICAL MODEL; SURFACE; SYSTEM; ARRAY;
D O I
10.1109/TNSRE.2024.3434360
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tongue motor function is crucial in a wide range of basic activities and its impairment affects quality of life. The electrophysiological assessment of the tongue relies primarily on needle electromyography, which is limited by its invasiveness and inability to capture the concurrent activity of the different tongue muscles. This work aimed at developing an intraoral grid for high-density surface electromyography (HDsEMG) to non-invasively map the electrical excitation of tongue muscles. We developed a grid of 4 x 8 electrodes deposited over an adhesive 8- $\mu $ m thick polyurethane membrane. The testing protocol was conducted on 7 healthy participants and included functional tasks (vowels articulation and tongue movements) aimed at activating different regions of the tongue. The electrical stability of contact was assessed by measuring electrode-tongue impedances before and after the tasks. The spatial amplitude distribution of global EMG and single motor unit action potentials (MUAPs) was characterized. Electrode-tongue impedance magnitude showed no significant changes in the pre-post comparison (58 +/- 46k Omega vs. 67 +/- 58k Omega at 50Hz). Contact stability was confirmed by the quality of the signals that allowed to quantify spatiotemporal characteristics of muscle activation during the different tasks. The analysis of the spatial distribution of individual MUAPs amplitude showed that they were confined to relatively small areas on the tongue surface (range: 0.5cm(2) -3.9cm(2)). A variety of different spatiotemporal MUAP patterns, likely due to the presence of different muscle compartments with different fiber orientations, were observed. Our results demonstrate that the developed electrode grid enables HDsEMG acquisition from the tongue during functional tasks, thus opening new possibilities in tongue muscle assessment both at global and single motor unit level.
引用
收藏
页码:2805 / 2814
页数:10
相关论文
共 50 条
  • [31] Analysis of motor unit spike trains estimated from high-density surface electromyography is highly reliable across operators
    Hug, Francois
    Avrillon, Simon
    Del Vecchio, Alessandro
    Casolo, Andrea
    Ibanez, Jaime
    Nuccio, Stefano
    Rossato, Julien
    Holobar, Ales
    Farina, Dario
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2021, 58
  • [32] SELECTIVITY OF CONVENTIONAL ELECTRODES FOR RECORDING MOTOR EVOKED POTENTIALS: AN INVESTIGATION WITH HIGH-DENSITY SURFACE ELECTROMYOGRAPHY
    Gallina, Alessio
    Peters, Sue
    Neva, Jason L.
    Boyd, Lara A.
    Garland, S. Jayne
    MUSCLE & NERVE, 2017, 55 (06) : 828 - 834
  • [33] Assessment of motor unit firing by high-density surface electromyography detects motor neuronal hyperexcitable state in amyotrophic lateral sclerosis
    Noto, Yu-ichi
    Kitaoji, Takamasa
    Watanabe, Kohei
    Mizuno, Toshiki
    MUSCLE & NERVE, 2023, 68 (02) : 149 - 156
  • [34] A Novel High-Density Electromyography Probe for Evaluating Anorectal Neurophysiology: Design, Human Feasibility Study, and Validation with Trans-Sacral Magnetic Stimulation
    Niranchan Paskaranandavadivel
    Chris Varghese
    Jaime Lara
    Shasti Ramachandran
    Leo Cheng
    Ales Holobar
    Armen Gharibans
    Ian Bissett
    Rowan Collinson
    Cathy Stinear
    Gregory O’Grady
    Annals of Biomedical Engineering, 2021, 49 : 502 - 514
  • [35] A Novel High-Density Electromyography Probe for Evaluating Anorectal Neurophysiology: Design, Human Feasibility Study, and Validation with Trans-Sacral Magnetic Stimulation
    Paskaranandavadivel, Niranchan
    Varghese, Chris
    Lara, Jaime
    Ramachandran, Shasti
    Cheng, Leo
    Holobar, Ales
    Gharibans, Armen
    Bissett, Ian
    Collinson, Rowan
    Stinear, Cathy
    O'Grady, Gregory
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (01) : 502 - 514
  • [36] Biceps Brachii Muscle Innervation Zone Location in Healthy Subjects Using High-Density Surface Electromyography
    Guzman, Rodrigo A.
    Silvestre, Rony A.
    Arriagada, David A.
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2011, 29 (02): : 347 - 352
  • [37] Physical and electrophysiological motor unit characteristics are revealed with simultaneous high-density electromyography and ultrafast ultrasound imaging
    Carbonaro, Marco
    Meiburger, Kristen M.
    Seoni, Silvia
    Hodson-Tole, Emma F.
    Vieira, Taian
    Botter, Alberto
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [38] Sex differences in the detection of motor unit action potentials identified using high-density surface electromyography
    Taylor, Christopher A.
    Kopicko, Brian H.
    Negro, Francesco
    Thompson, Christopher K.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2022, 65
  • [39] Semi-Automated Identification of Motor Units Concurrently Recorded in High-Density Surface and Intramuscular Electromyography
    Yeung, Dennis
    Negro, Francesco
    Vujaklija, Ivan
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [40] Electrode Shift Robust CNN for High-Density Myoelectric Pattern Recognition Control
    Wu, Le
    Liu, Aiping
    Zhang, Xu
    Chen, Xiang
    Chen, Xun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71