Prediction of intraoperative press-fit stability of the acetabular cup in total hip arthroplasty using radiomics-based machine learning models

被引:0
作者
He, Bin [1 ,3 ]
Zhang, Xin [1 ]
Peng, Shengwang [2 ]
Zeng, Dong [2 ]
Chen, Haicong [1 ]
Liang, Zhenming [1 ]
Zhong, Huan [1 ]
Ouyang, Hanbin [1 ]
机构
[1] Guangdong Med Univ Zhanjiang, Affiliated Hosp, Joint Surg Dept Orthoped Ctr, 57 Renmin Ave South, Zhanjiang 524001, Guangdong, Peoples R China
[2] Southern Med Univ, Sch Biomed Engn, Guangzhou 510515, Peoples R China
[3] 958 Hosp Chinese Peoples Liberat Army, Southwest Hosp Jiangbei Area, Dept Orthoped, Chongqing 400020, Peoples R China
关键词
Radiomics; Machine Learning; Total Hip Arthroplasty; Acetabulum; Press-fit; BONE QUALITY; RISK-FACTORS; MIGRATION; FIXATION;
D O I
10.1016/j.ejrad.2024.111751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Preoperative prediction of the acetabular cup press-fit stability in total hip arthroplasty is necessary for clinical decision-making. This study aims to establish and validate machine learning models to investigate the feasibility of predicting the intraoperative press-fit stability of the acetabular cup in total hip arthroplasty (THA). Methods: 226 patients who underwent primary THA from 2018 to 2022 in our hospital were retrospectively enrolled. Patients were divided into press-fit stable or unstable groups according to the intraoperative pull-out test of the implanted cup. Then, they were randomly assigned to the training or test cohort in an 8:2 ratio. We used 3Dslicer software to segment the region of interest (ROI) of the patient's bilateral hip X-ray to extract radiomics features. The least absolute shrinkage and selection operator (LASSO) regression was used in our feature selection. Finally, four machine learning models were employed in this study, including support vector machine (SVM), random forest (RF), logistic regression (LR), and XGBoost (XGB). Decision curve analysis (DCA), and receiver operating characteristic (ROC) curves of the models were plotted. The area under the curve (AUC), diagnostic accuracy, sensitivity, and specificity were calculated as well. The AUCs of the four models were compared using the DeLong test. Results: Twenty-seven valuable radiomics features were determined by dimensionality reduction and selection. Regarding to the DeLong test, the AUC of the XGB model was significantly different from those of the other three models. (p < 0.05). Among all models, the XGB model exhibited the best performance with an AUC of 0.823 (95 % CI: 0.711-0.919) in the test cohort and showed optimal clinical efficacy according to the DCA. Conclusion: Machine learning models based on X-ray radiomics can accurately predict the intraoperative press-fit stability of implanted cups preoperatively, providing surgeons with valuable information to lower the complication risk in THA.
引用
收藏
页数:8
相关论文
共 40 条
[1]   Factors influencing initial cup stability in total hip arthroplasty [J].
Amirouche, Farid ;
Solitro, Giovanni ;
Broviak, Stefanie ;
Gonzalez, Mark ;
Goldstein, Wayne ;
Barmada, Riad .
CLINICAL BIOMECHANICS, 2014, 29 (10) :1177-1185
[2]   Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: A biomechanical model [J].
Bellini, Chiara Maria ;
Galbusera, Fabio ;
Ceroni, Roberto Giacometti ;
Raimondi, Manuela Teresa .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (02) :175-181
[3]   Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene [J].
Braun, Steffen ;
Vardag, Shirin ;
Mueller, Ulrike ;
Schroeder, Stefan ;
Sonntag, Robert ;
Bormann, Therese ;
Gotterbarm, Tobias ;
Kretzer, Jan Philippe .
ACTA BIOMATERIALIA, 2019, 97 :239-246
[4]   Risk factors for unsuccessful acetabular press-fit fixation at primary total hip arthroplasty [J].
Brulc, U. ;
Antolic, V. ;
Mavcic, B. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (07) :993-997
[5]   Novel radiomics evaluation of bone formation utilizing multimodal (SPECT/X-ray CT) in vivo imaging [J].
Budan, Ferenc ;
Szigeti, Krisztian ;
Weszl, Miklos ;
Horvath, Ildiko ;
Balogh, Erika ;
Kanaan, Reem ;
Berenyi, Karoly ;
Lacza, Zsombor ;
Mathe, Domokos ;
Gyongyi, Zoltan .
PLOS ONE, 2018, 13 (09)
[6]   Autophagy inhibitors 3-MA and LY294002 repress osteoclastogenesis and titanium particle-stimulated osteolysis [J].
Chen, Weishen ;
Xian, Guoyan ;
Gu, Minghui ;
Pan, Baiqi ;
Wu, Xiaoyu ;
Ye, Yongyu ;
Zheng, Linli ;
Zhang, Ziji ;
Sheng, Puyi .
BIOMATERIALS SCIENCE, 2021, 9 (14) :4922-4935
[7]   A novel method to assess primary stability of press-fit acetabular cups [J].
Crosnier, Emilie A. ;
Keogh, Patrick S. ;
Miles, Anthony W. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (11) :1126-1134
[8]   Risk Assessment of Hip Fracture Based on Machine Learning [J].
Galassi, Alessio ;
Martin-Guerrero, Jose D. ;
Villamor, Eduardo ;
Monserrat, Carlos ;
Ruperez, Maria Jose .
APPLIED BIONICS AND BIOMECHANICS, 2020, 2020
[9]   Dynamic trial fitting by an expanding trial cup does not jeopardize primary acetabular component stability [J].
Hoornenborg, D. ;
van Loon, J. ;
de Waard, S. ;
Sierevelt, I. N. ;
Opdam, K. T. M. ;
Kerkhoffs, G. M. M. J. ;
Haverkamp, D. .
CLINICAL BIOMECHANICS, 2020, 78
[10]   The number of screws, bone quality, coefficient affect acetabular cup and friction stability [J].
Hsu, Jui-Ting ;
Chang, Chih-Han ;
Huang, Heng-Li ;
Zobitz, Mark E. ;
Chen, Weng-Pin ;
Lai, Kuo-An ;
An, Kai-Nan .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) :1089-1095