Evaluation of the accuracy of automated tooth segmentation of intraoral scans using artificial intelligence-based software packages

被引:0
|
作者
Yacout, Yomna M. [1 ]
Eid, Farah Y. [1 ]
Tageldin, Mostafa A. [1 ]
Kassem, Hassan E. [1 ]
机构
[1] Alexandria Univ, Fac Dent, Dept Orthodont, Champoll St,POB 21521, Alexandria, Egypt
关键词
MODELS; SETUPS;
D O I
10.1016/j.ajodo.2024.05.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The accuracy of tooth segmentation in intraoral scans is crucial for performing virtual setups and appliance fabrication. Hence, the objective of this study was to estimate and compare the accuracy of automated tooth segmentation generated by the artificial intelligence of dentOne software (DIORCO Co, Ltd, Yongin, South mandibular pretreatment dental scan sets comprising 286 teeth were collected for this investigation from the archives of the Department of Orthodontics, Faculty of Dentistry, Alexandria University. The scans were imported as standard tessellation language files into both dentOne and Medit Ortho Simulation software. Automatic segmentation was run on each software. The number of successfully segmented teeth vs failed segmentations was recorded to determine the success rate of automated segmentation of each program. Evaluation of success and/ or failure was based on the software's identification of the teeth and the quality of the segmentation. The mesiodistal tooth width measurements after segmentation using both tested software programs were compared with those measured on the unsegmented scan using Meshmixer software (Autodesk, San Rafael, Calif). The unsegmented scans served as the reference standard. Results: A total of 288 teeth were examined. Successful identification rates were 99% and 98.3% for Medit and dentOne, respectively. Success rates of segmenting the lingual surfaces of incisors were significantly higher in Medit than in dentOne (93.7% vs 66.7%, respectively; P <0.001). DentOne overestimated the mesiodistal width of canines (0.11 mm, P = 0.032), premolars (0.22 mm, P < 0.001), and molars (0.14 mm, P = 0.043) compared with the reference standard, whereas Medit overestimated the mesiodistal width of premolars only (0.13 mm, P = 0.006). Bland-Altman plots showed that mesiodistal tooth width agreement limits exceeded 0.2 mm between each software and the reference standard. Conclusions: Both artificial intelligence-segmentation software demonstrated acceptable accuracy in tooth segmentation. There is a need for improvement in segmenting incisor lingual tooth surfaces in dentOne. Both software programs tended to overestimate the mesiodistal widths of segmented teeth, particularly the premolars. Artificial intelligence-segmentation needs to be manually adjusted by the operator to ensure accuracy. However, this still does not solve the problem of proximal surface reconstruction by the software.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Evaluation of the accuracy and reliability of WebCeph - An artificial intelligence-based online software
    Katyal, Deepika
    Balakrishnan, Nivethigaa
    APOS TRENDS IN ORTHODONTICS, 2022, 12 (04) : 271 - 276
  • [2] Convolutional neural network for automated tooth segmentation on intraoral scans
    Wang, Xiaotong
    Alqahtani, Khalid Ayidh
    van den Bogaert, Tom
    Shujaat, Sohaib
    Jacobs, Reinhilde
    Shaheen, Eman
    BMC ORAL HEALTH, 2024, 24 (01):
  • [3] Accuracy of artificial intelligence-based segmentation of the mandibular canal in CBCT
    Ntovas, Panagiotis
    Marchand, Laurent
    Finkelman, Matthew
    Revilla-Leon, Marta
    Att, Wael
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (09) : 1163 - 1171
  • [4] Automated weight-bearing foot measurements using an artificial intelligence-based software
    Lassalle, Louis
    Regnard, Nor-eddine
    Ventre, Jeanne
    Marty, Vincent
    Clovis, Lauryane
    Zhang, Zekun
    Nitche, Nicolas
    Guermazi, Ali
    Laredo, Jean-Denis
    SKELETAL RADIOLOGY, 2025, 54 (02) : 229 - 241
  • [5] PERFORMANCE EVALUATION OF AN ARTIFICIAL INTELLIGENCE-BASED SOFTWARE FOR OPPORTUNISTIC DETECTION OF VERTEBRAL COMPRESSION FRACTURES ON CT SCANS
    Ayobi, A.
    Chow, D.
    Soun, J.
    Chang, P.
    Castineira, C.
    Kiewsky, J.
    Mahfoud, M.
    Avare, C.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2024, 36 : S105 - S105
  • [6] Accuracy of artificial intelligence-based segmentation in maxillofacial structures: a systematic review
    Alahmari, Manea
    Alahmari, Maram
    Almuaddi, Abdulmajeed
    Abdelmagyd, Hossam
    Rao, Kumuda
    Hamdoon, Zaid
    Alsaegh, Mohammed
    Chaitanya, Nallan C. S. K.
    Shetty, Shishir
    BMC ORAL HEALTH, 2025, 25 (01):
  • [7] Automated Evaluation and Rating of Product Repairability Using Artificial Intelligence-Based Approaches
    Liao, Hao-Yu
    Esmaeilian, Behzad
    Behdad, Sara
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (02):
  • [8] Correction to: Accuracy of artificial intelligence-based segmentation in maxillofacial structures: a systematic review
    Manea Alahmari
    Maram Alahmari
    Abdulmajeed Almuaddi
    Hossam Abdelmagyd
    Kumuda Rao
    Zaid Hamdoon
    Mohammed Alsaegh
    Nallan C. S. K. Chaitanya
    Shishir Shetty
    BMC Oral Health, 25 (1)
  • [9] Automated monitoring of tooth wear progression using AI on intraoral scans
    van Nistelrooij, Niels
    Maier, Eva
    Bronkhorst, Hilde
    Crins, Luuk
    Xi, Tong
    Loomans, Bas A. C.
    Vinayahalingam, Shankeeth
    JOURNAL OF DENTISTRY, 2024, 150
  • [10] Evaluation of an artificial intelligence-based algorithm for automated localization of craniofacial landmarks
    Blum, Friederike Maria Sophie
    Moehlhenrich, Stephan Christian
    Raith, Stefan
    Pankert, Tobias
    Peters, Florian
    Wolf, Michael
    Hoelzle, Frank
    Modabber, Ali
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (05) : 2255 - 2265