A Biomechanical Study Comparing Different Configurations of the Ilizarov Mini-fixator and Plate Fixation

被引:0
|
作者
Nishimura, Reiji [1 ]
Ogino, Naohiko [2 ]
Miyawaki, Takeshi [1 ]
Matsuura, Shintaro [1 ]
Fujii, Mikako [1 ]
Akaishi, Wataru [1 ]
Bo, Hideaki [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Plast & Reconstruct Surg, Tokyo, Japan
[2] Gunma Ind Technol Ctr, Maebashi, Gunma, Japan
来源
JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY | 2022年 / 1卷 / 02期
关键词
biomechanical study; external fixator; hand surgery; Ilizarov; EXTERNAL FIXATION; FRACTURE; HAND; DISLOCATIONS; MANAGEMENT; RIGIDITY; HISTORY; DEVICES; LOADS;
D O I
10.53045/jprs.2021-0018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: The Ilizarov mini-fixator, an external fixator developed for digits, has a structure different from that of general unilateral external fixators. The purpose of this study was to provide information for clinical external fixator selection by clarifying the biomechanical properties of the Ilizarov mini-fixator. Methods: Three types of loads were applied to the fracture fixation model using a carbon fiber cylinder as the bone model: axial pressure, 4-point bending, and torsion. Ilizarov mini-fixators with six 1.5 mm pins (6-pin group), four 1.5 mm pins (4-pin group), and four 2.0 mm-threaded-pins (2 mm-pin group) and a group using a 1.5-mm plate (plate group) were set, and the stiffness was compared between these four groups. Results: Compared to the 6-pin group, which is the basic configuration of the Ilizarov mini-fixator, the 4-pin group had lower stiffness against axial load and bending, and there was no significant difference in stiffness against torsion. The 2 mm-pin group had high stiffness against axial load and bending and low stiffness against torsion. The plate group exhibited high stiffness against axial pressure and low stiffness against bending and torsion. Conclusions: The Ilizarov mini-fixator is a reasonable option for fixing small phalanges. However, other options should be considered for the fixation of larger bones with higher loads. In particular, a configuration with fewer pins such as the 4-pin model may have insufficient strength during early postoperative exercise, even for fixing the phalanges.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [41] Locking plate fixation of humeral head fractures with a telescoping screw. A comparative biomechanical study versus a standard plate
    Gradl, Gertraud
    Stedtfeld, Hans-Werner
    Morlock, Michael
    Sellenschloh, Kay
    Pueschel, Klaus
    Mittlmeier, Thomas
    Gradl, Georg
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 734 - 738
  • [42] Minimally Invasive Intramedullary Screw Versus Plate Fixation for Proximal Phalanx Fractures: A Biomechanical Study
    Miles, Megan R.
    Krul, Kevin P.
    Abbasi, Pooyan
    Thakkar, Madhuli Y.
    Giladi, Aviram M.
    Means, Kenneth R., Jr.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2021, 46 (06): : 518.e1 - 518.e8
  • [43] A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation
    Rebgetz, Paul R.
    Daniele, Luca
    Underhill, Ian D.
    Ochsner, Andreas
    Taylor, Fraser J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (04) : E111 - E116
  • [44] A biomechanical study of locking spongious screws and failure rates are higher than expected in plate fixation
    Parmaksizoglu, Fatih
    Cetin, Onur
    Kilic, Sinan
    Ince, Yener
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [45] Determination of the ideal plate for medial femoral condyle fracture fixation: an anatomical fit and biomechanical study
    Leung, Felix
    Fang, Christian Xinshuo
    Yung, Colin Shing Yat
    Leung, Frankie Ka Li
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [46] Prospective Randomized Study Comparing the External Fixator and Volar Locking Plate in Intraarticular Distal Radius Fractures: Which Is Better?
    Sharma, Aryan
    Pathak, Subodh
    Sandhu, Harinder
    Bagtharia, Priyank
    Kumar, Naveen
    Bajwa, Rajdeep S.
    Pruthi, Vineet
    Chawla, Jasneet S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (02)
  • [47] A Biomechanical Study of Tuberosity-Based Locked Plate Fixation Compared with Standard Proximal Humeral Locking Plate Fixation for 3-Part Proximal Humeral Fractures
    Walker, Robert
    Castaneda, Paulo
    Putnam, Jill G.
    Schemitsch, Emil H.
    McKee, Michael D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (07) : E233 - E238
  • [48] A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius-A biomechanical study
    Windolf, Markus
    Schwieger, Karsten
    Ockert, Ben
    Jupiter, Jesse B.
    Gradl, Georg
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 204 - 209
  • [49] Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
    Neto, Jorge Raduan
    de Moraes, Vinicius Ynoe
    Gomes dos Santos, Joao B.
    Faloppa, Flavio
    Belloti, Joao Carlos
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [50] Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
    Jorge Raduan Neto
    Vinicius Ynoe de Moraes
    João B Gomes dos Santos
    Flávio Faloppa
    João Carlos Belloti
    BMC Musculoskeletal Disorders, 15