A Biomechanical Study Comparing Different Configurations of the Ilizarov Mini-fixator and Plate Fixation

被引:0
|
作者
Nishimura, Reiji [1 ]
Ogino, Naohiko [2 ]
Miyawaki, Takeshi [1 ]
Matsuura, Shintaro [1 ]
Fujii, Mikako [1 ]
Akaishi, Wataru [1 ]
Bo, Hideaki [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Plast & Reconstruct Surg, Tokyo, Japan
[2] Gunma Ind Technol Ctr, Maebashi, Gunma, Japan
来源
JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY | 2022年 / 1卷 / 02期
关键词
biomechanical study; external fixator; hand surgery; Ilizarov; EXTERNAL FIXATION; FRACTURE; HAND; DISLOCATIONS; MANAGEMENT; RIGIDITY; HISTORY; DEVICES; LOADS;
D O I
10.53045/jprs.2021-0018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: The Ilizarov mini-fixator, an external fixator developed for digits, has a structure different from that of general unilateral external fixators. The purpose of this study was to provide information for clinical external fixator selection by clarifying the biomechanical properties of the Ilizarov mini-fixator. Methods: Three types of loads were applied to the fracture fixation model using a carbon fiber cylinder as the bone model: axial pressure, 4-point bending, and torsion. Ilizarov mini-fixators with six 1.5 mm pins (6-pin group), four 1.5 mm pins (4-pin group), and four 2.0 mm-threaded-pins (2 mm-pin group) and a group using a 1.5-mm plate (plate group) were set, and the stiffness was compared between these four groups. Results: Compared to the 6-pin group, which is the basic configuration of the Ilizarov mini-fixator, the 4-pin group had lower stiffness against axial load and bending, and there was no significant difference in stiffness against torsion. The 2 mm-pin group had high stiffness against axial load and bending and low stiffness against torsion. The plate group exhibited high stiffness against axial pressure and low stiffness against bending and torsion. Conclusions: The Ilizarov mini-fixator is a reasonable option for fixing small phalanges. However, other options should be considered for the fixation of larger bones with higher loads. In particular, a configuration with fewer pins such as the 4-pin model may have insufficient strength during early postoperative exercise, even for fixing the phalanges.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [31] Anterior subcutaneous internal fixator (INFIX) versus plate fixation for anterior ring injury in Tile C pelvic fractures: a retrospective study
    Huang, Shenbo
    He, Shuai
    Kenmegne, Guy Romeo
    Yin, Yijie
    Yu, You
    Fang, Yue
    BMC SURGERY, 2025, 25 (01)
  • [32] Is intrathoracic rib plate fixation advantageous over extrathoracic plating? A biomechanical cadaveric study
    Mischler, Dominic
    Schopper, Clemens
    Gasparri, Mario
    Schulz-Drost, Stefan
    Brace, Michael
    Gueorguiev, Boyko
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2022, 92 (03) : 574 - 580
  • [33] Prospective continuous study comparing intrafocal cross-pinning HK2® with a locking plate in distal radius fracture fixation
    Maire, N.
    Lebailly, F.
    Zemirline, A.
    Hariri, A.
    Facca, S.
    Liverneaux, P.
    CHIRURGIE DE LA MAIN, 2013, 32 (01) : 17 - 24
  • [34] Biomechanical study of Proximal humeral fracture fixation: Locking plate with medial support screw vs. locking plate with intramedullary fibular graft
    Jang, Younghwan
    Kim, Doosup
    CLINICAL BIOMECHANICS, 2021, 90
  • [35] Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study
    Hessmann, Martin H.
    Korner, Jan
    Hofmann, Alexander
    Sternstein, Werner
    Rommens, Pol M.
    BIOMEDIZINISCHE TECHNIK, 2008, 53 (03): : 130 - 137
  • [36] Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study
    Markolf, Keith L.
    Cheung, Edward
    Joshi, Nirav B.
    Boguszewski, Daniel V.
    Petrigliano, Frank A.
    McAllister, David R.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2016, 44 (06) : 1590 - 1596
  • [37] Symphyseal internal rod fixation versus standard plate fixation for open book pelvic ring injuries: a biomechanical study
    G. Osterhoff
    S. Tiziani
    C. Hafner
    S. J. Ferguson
    H.-P. Simmen
    C. M. L. Werner
    European Journal of Trauma and Emergency Surgery, 2016, 42 : 197 - 202
  • [38] Unilateral external fixator and its biomechanical effects in treating different types of femoral fracture: A finite element study with experimental validated model
    Aziz, Aishah Umairah Abd
    Ammarullah, Muhammad Imam
    Ng, Bing Wui
    Gan, Hong-Seng
    Kadir, Mohammed Rafiq Abdul
    Ramlee, Muhammad Hanif
    HELIYON, 2024, 10 (04)
  • [39] Symphyseal internal rod fixation versus standard plate fixation for open book pelvic ring injuries: a biomechanical study
    Osterhoff, G.
    Tiziani, S.
    Hafner, C.
    Ferguson, S. J.
    Simmen, H. -P.
    Werner, C. M. L.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2016, 42 (02) : 197 - 202
  • [40] Percutaneous fixation of intraarticular joint-depression calcaneal fractures with different screw configurations - a biomechanical human cadaveric analysis
    Ivanov, Stoyan
    Stefanov, Aleksandar
    Zderic, Ivan
    Rodemund, Christian
    Schepers, Tim
    Gehweiler, Dominic
    Dauwe, Jan
    Pastor, Torsten
    Makelov, Biser
    Raykov, Dimitur
    Richards, Geoff
    Gueorguiev, Boyko
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (04) : 3305 - 3315