A Biomechanical Study Comparing Different Configurations of the Ilizarov Mini-fixator and Plate Fixation

被引:0
|
作者
Nishimura, Reiji [1 ]
Ogino, Naohiko [2 ]
Miyawaki, Takeshi [1 ]
Matsuura, Shintaro [1 ]
Fujii, Mikako [1 ]
Akaishi, Wataru [1 ]
Bo, Hideaki [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Plast & Reconstruct Surg, Tokyo, Japan
[2] Gunma Ind Technol Ctr, Maebashi, Gunma, Japan
来源
JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY | 2022年 / 1卷 / 02期
关键词
biomechanical study; external fixator; hand surgery; Ilizarov; EXTERNAL FIXATION; FRACTURE; HAND; DISLOCATIONS; MANAGEMENT; RIGIDITY; HISTORY; DEVICES; LOADS;
D O I
10.53045/jprs.2021-0018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: The Ilizarov mini-fixator, an external fixator developed for digits, has a structure different from that of general unilateral external fixators. The purpose of this study was to provide information for clinical external fixator selection by clarifying the biomechanical properties of the Ilizarov mini-fixator. Methods: Three types of loads were applied to the fracture fixation model using a carbon fiber cylinder as the bone model: axial pressure, 4-point bending, and torsion. Ilizarov mini-fixators with six 1.5 mm pins (6-pin group), four 1.5 mm pins (4-pin group), and four 2.0 mm-threaded-pins (2 mm-pin group) and a group using a 1.5-mm plate (plate group) were set, and the stiffness was compared between these four groups. Results: Compared to the 6-pin group, which is the basic configuration of the Ilizarov mini-fixator, the 4-pin group had lower stiffness against axial load and bending, and there was no significant difference in stiffness against torsion. The 2 mm-pin group had high stiffness against axial load and bending and low stiffness against torsion. The plate group exhibited high stiffness against axial pressure and low stiffness against bending and torsion. Conclusions: The Ilizarov mini-fixator is a reasonable option for fixing small phalanges. However, other options should be considered for the fixation of larger bones with higher loads. In particular, a configuration with fewer pins such as the 4-pin model may have insufficient strength during early postoperative exercise, even for fixing the phalanges.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [21] A biomechanical study comparing minimally invasive anterior pelvic ring fixation techniques to external fixation
    MacCormicka, Lauren M.
    Chen, Frank
    Gilbertson, Jeff
    Khana, Sikandar
    Schroder, Lisa K.
    Bechtolda, Joan E.
    Cole, Peter A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (02): : 251 - 255
  • [22] Biomechanical analysis between Orthofix® external fixator and different K-wire configurations for pediatric supracondylar humerus fractures
    Wen-Chao Li
    Qing-Xu Meng
    Rui-Jiang Xu
    Gang Cai
    Hui Chen
    Hong-Juan Li
    Journal of Orthopaedic Surgery and Research, 13
  • [23] Salvage procedures for trochanteric femoral fractures after internal fixation failure: Biomechanical comparison of a plate fixator and the dynamic condylar screw
    Konstantinidis, L.
    Papaioannou, C.
    Mehlhorn, A.
    Hirschmueller, A.
    Suedkamp, N. P.
    Helwig, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H7) : 710 - 717
  • [24] Fibula Nail versus Locking Plate Fixation-A Biomechanical Study
    Kohler, Felix Christian
    Schenk, Philipp
    Nies, Theresa
    Hallbauer, Jakob
    Hofmann, Gunther Olaf
    Biedermann, Uta
    Kielstein, Heike
    Wildemann, Britt
    Ramm, Roland
    Ullrich, Bernhard Wilhelm
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [25] Periprosthetic fracture fixation in Vancouver B1 femoral shaft fractures: A biomechanical study comparing two plate systems
    Waehnert, Dirk
    Mueller, Marcus
    Tiedemann, Hendrik
    Maerdian, Sven
    Raschke, Michael J.
    Koesters, Clemens
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 24 : 150 - 154
  • [26] A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading
    Afshar, R.
    Fong, T. S.
    Latifi, M. Hadi
    Kanthan, S. R.
    Kamarul, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (05) : 396 - 401
  • [27] Biomechanical analysis between Orthofix(R) external fixator and different K-wire configurations for pediatric supracondylar humerus fractures
    Li, Wen-Chao
    Meng, Qing-Xu
    Xu, Rui-Jiang
    Cai, Gang
    Chen, Hui
    Li, Hong-Juan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [28] Comparing case-control study for treatment of proximal tibia fractures with a complete metaphyseal component in two centers with different distinct strategies: fixation with Ilizarov frame or locking plates
    Haakon Berven
    Michael Brix
    Kaywan Izadpanah
    Eva Johanna Kubosch
    Hagen Schmal
    Journal of Orthopaedic Surgery and Research, 13
  • [29] Angular stable lateral plating is a valid alternative to conventional plate fixation in the proximal phalanx. A biomechanical study
    Shanmugam, R.
    Ernst, M.
    Stoffel, K.
    Fischer, M. F.
    Wahl, D.
    Richards, R. G.
    Gueorguiev, B.
    CLINICAL BIOMECHANICS, 2015, 30 (05) : 405 - 410
  • [30] Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness
    Ang, B. F. H.
    Chen, J. Y.
    Yew, A. K. S.
    Chua, S. K.
    Chou, S. M.
    Chia, S. L.
    Koh, J. S. B.
    Howe, T. S.
    BONE & JOINT RESEARCH, 2017, 6 (04): : 216 - 223