A Biomechanical Study Comparing Different Configurations of the Ilizarov Mini-fixator and Plate Fixation

被引:0
|
作者
Nishimura, Reiji [1 ]
Ogino, Naohiko [2 ]
Miyawaki, Takeshi [1 ]
Matsuura, Shintaro [1 ]
Fujii, Mikako [1 ]
Akaishi, Wataru [1 ]
Bo, Hideaki [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Plast & Reconstruct Surg, Tokyo, Japan
[2] Gunma Ind Technol Ctr, Maebashi, Gunma, Japan
来源
JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY | 2022年 / 1卷 / 02期
关键词
biomechanical study; external fixator; hand surgery; Ilizarov; EXTERNAL FIXATION; FRACTURE; HAND; DISLOCATIONS; MANAGEMENT; RIGIDITY; HISTORY; DEVICES; LOADS;
D O I
10.53045/jprs.2021-0018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: The Ilizarov mini-fixator, an external fixator developed for digits, has a structure different from that of general unilateral external fixators. The purpose of this study was to provide information for clinical external fixator selection by clarifying the biomechanical properties of the Ilizarov mini-fixator. Methods: Three types of loads were applied to the fracture fixation model using a carbon fiber cylinder as the bone model: axial pressure, 4-point bending, and torsion. Ilizarov mini-fixators with six 1.5 mm pins (6-pin group), four 1.5 mm pins (4-pin group), and four 2.0 mm-threaded-pins (2 mm-pin group) and a group using a 1.5-mm plate (plate group) were set, and the stiffness was compared between these four groups. Results: Compared to the 6-pin group, which is the basic configuration of the Ilizarov mini-fixator, the 4-pin group had lower stiffness against axial load and bending, and there was no significant difference in stiffness against torsion. The 2 mm-pin group had high stiffness against axial load and bending and low stiffness against torsion. The plate group exhibited high stiffness against axial pressure and low stiffness against bending and torsion. Conclusions: The Ilizarov mini-fixator is a reasonable option for fixing small phalanges. However, other options should be considered for the fixation of larger bones with higher loads. In particular, a configuration with fewer pins such as the 4-pin model may have insufficient strength during early postoperative exercise, even for fixing the phalanges.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [1] Biomechanical study of a modified application of Ilizarov external mini-fixator for metacarpal neck fractures: a comparative analysis
    Chen Xie
    Yanchen Dong
    Zhaozhe Yao
    Zongyu Li
    Journal of Orthopaedic Surgery and Research, 20 (1)
  • [2] Correction of Severe Contracture of Intrinsic Plus Hand with a Modified Ilizarov Mini-Fixator
    Hamada, Yoshitaka
    Sairyo, Koichi
    Hibino, Naohito
    Kobayashi, Anna
    JOURNAL OF HAND AND MICROSURGERY, 2015, 7 (01) : 161 - 165
  • [3] Ulnar osteotomy and the ilizarov mini-fixator for pediatric chronic monteggia fracture-dislocations
    Take, Masaki
    Tomori, Yuji
    Sawaizumi, Takuya
    Majima, Tokifumi
    Nanno, Mitsuhiko
    Takai, Shinro
    MEDICINE, 2019, 98 (01) : E13978
  • [4] Minimally Invasive Corrective Osteotomy with the Ilizarov Mini-Fixator for Malunited Fractures of the Phalanges: Technical Note
    Tomori, Yuji
    Nanno, Mitsuhiko
    Sonoki, Kentaro
    Majima, Tokifumi
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2021, 88 (03) : 262 - 266
  • [5] In vitro biomechanical testing of different configurations of acrylic external skeletal fixator constructs
    Tyagi, S. K.
    Aithal, H. P.
    Kinjavdekar, P.
    Amarpal
    Pawde, A. M.
    Srivastava, T.
    Singh, J.
    Madhu, D. N.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2015, 28 (04) : 227 - 233
  • [6] Influence of Different Connecting Rod Configurations on the Stability of the Ilizarov/TSF Frame: A Biomechanical Study
    Thiart, Gerhard
    Herbert, Christopher
    Sivarasu, Sudesh
    Gasant, Saadiq
    Laubscher, Maritz
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2020, 15 (01) : 23 - 27
  • [7] Biomechanical study of different plate configurations for distal humerus osteosynthesis
    Bogataj, M.
    Kosel, F.
    Norris, R.
    Krkovic, M.
    Brojan, M.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (05) : 381 - 392
  • [8] Biomechanical study of different plate configurations for distal humerus osteosynthesis
    M. Bogataj
    F. Kosel
    R. Norris
    M. Krkovic
    M. Brojan
    Medical & Biological Engineering & Computing, 2015, 53 : 381 - 392
  • [9] A biomechanical comparison of micromotion after ankle fusion using 2 fixation techniques: Intramedullary arthrodesis nail or Ilizarov external fixator
    Fragomen, Austin T.
    Meyers, Kathleen N.
    Davis, Nicole
    Shu, Hengsheng
    Wright, Timmothy
    Rozbruch, S. Robert
    FOOT & ANKLE INTERNATIONAL, 2008, 29 (03) : 334 - 341
  • [10] Biomechanical comparison of different external fixator configurations for stabilization of supracondylar humerus fractures in children