Direct fluorescence and spectrophotometric-based detection of azithromycin using fluorescein isothiocyanate: Method development and comparative analysis

被引:4
作者
Hasaneen, Noha [1 ]
Pulicharla, Rama [1 ]
Brar, Satinder Kaur [1 ]
Rezai, Pouya [2 ]
机构
[1] York Univ, Lassonde Sch Engn, Dept Civil Engn, Toronto, ON M3J 1P3, Canada
[2] York Univ, Lassonde Sch Engn, Dept Mech Engn, Toronto, ON M3J 1P3, Canada
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2024年 / 12卷 / 03期
关键词
Azithromycin; Fluorescein isothiocyanate; Detection; Fluorescence; Spectrophotometric analysis; Contaminants; Urine; LOD; LOQ; PHARMACEUTICAL FORMULATIONS; MACROLIDE ANTIBIOTICS; HPLC; CLARITHROMYCIN; VALIDATION; ASSAY;
D O I
10.1016/j.jece.2024.112803
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
New methods for the analysis of azithromycin (AZM) have been devised, employing direct fluorescence and spectrophotometric techniques. This research focused on the development and validation of these methods, especially based on the formation of an ion-pair complex with fluorescein isothiocyanate (FITC). The resulting complex enhanced the fluorescence intensity at a wavelength of 520 nm and the absorbance at 480 nm. The impact of different solvent compositions was investigated, with methanol and a 1:1 mixture of methanol and Milli-Q proving to be the most sensitive. The optimal FITC concentration was determined as 50 mu g/ml, and the molar ratio of the AZM-FITC ion-pair complex was determined to be 1:1. Notably, an instantaneous increase in fluorescence intensity was observed, eliminating the need for incubation. The developed methods were validated for sensitivity, accuracy, and precision, with the fluorescence-based method demonstrating superior sensitivity and precision compared to the spectrophotometric method. Under optimum conditions, the fluorescence-based method achieved a linear range of 0-31.25 mu g/ml with a limit of detection (LOD) of 0.41 mu g/ml and a limit of quantification (LOQ) of 1.23 mu g/ml., In contrast, the spectrophotometric method had an LOD of 0.82 mu g/ml and an LOQ of 2.49 mu g/ml. Additionally, the fluorescence-based method exhibited a narrower recovery range in artificial urine samples, suggesting higher precision in complex matrices. Overall, these methods offer rapid and sensitive AZM analysis with potential applications in diverse matrices such as biological samples post-extraction.
引用
收藏
页数:9
相关论文
共 55 条
[51]   A wearable gloved sensor based on fluorescent Ag nanoparticles and europium complexes for visualized assessment of tetracycline in food samples [J].
Xu, Jun ;
Wang, Junxi ;
Li, Yongxin ;
Zhang, Lina ;
Bi, Ning ;
Gou, Jian ;
Zhao, Tongqian ;
Jia, Lei .
FOOD CHEMISTRY, 2023, 424
[52]   A smartphone-integrated method for visual detection of tetracycline [J].
Xu, Jun ;
Guo, Shengli ;
Jia, Lei ;
Zhu, Tinghui ;
Chen, Xiangzhen ;
Zhao, Tongqian .
CHEMICAL ENGINEERING JOURNAL, 2021, 416
[53]   Determination of azithromycin by ion-pair HPLC with UV detection [J].
Yang, Zi Yi ;
Wang, Lin ;
Tang, Xing .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) :811-815
[54]   Super Stable Fluorescein Isothiocyanate Isomer I Monolayer for Total Internal Reflection Fluorescence Microscopy [J].
Zarski, Przemyslaw ;
Ryder, Alan G. .
LANGMUIR, 2018, 34 (37) :10913-10923
[55]   Occurrence of typical antibiotics, representative antibiotic-resistant bacteria, and genes in fresh and stored source-separated human urine [J].
Zhou, Xiaoqin ;
Cuasquer, Gabriela Jacqueline Perez ;
Li, Zifu ;
Mang, Heinz Peter ;
Lv, Yaping .
ENVIRONMENT INTERNATIONAL, 2021, 146