Development of a multiplex droplet digital PCR assay for simultaneous detection and quantification of Escherichia coli, E. marmotae, and E. ruysiae in water samples

被引:3
|
作者
Moinet, Marie [1 ]
Collis, Rose M. [1 ]
Rogers, Lynn [1 ,2 ]
Devane, Megan L. [3 ]
Biggs, Patrick J. [2 ,4 ]
Stott, Rebecca [5 ]
Marshall, Jonathan [6 ]
Muirhead, Richard [7 ]
Cookson, Adrian L. [1 ,2 ]
机构
[1] AgResearch Ltd, Hopkirk Res Inst, Food Syst Integr Team, Tennent Dr, Palmerston North 4442, New Zealand
[2] Massey Univ, Hopkirk Res Inst, Sch Vet Sci, MEpiLab, Tennent Dr, Palmerston North 4442, New Zealand
[3] Inst Environm Sci & Res Ltd ESR, 27 Creyke Rd, Christchurch 8041, New Zealand
[4] Massey Univ, Sch Nat Sci, Tennent Dr, Palmerston North 4442, New Zealand
[5] Natl Inst Water & Atmospher Res NIWA, Gate 10 Silverdale Rd, Hamilton 3216, New Zealand
[6] Massey Univ, Sch Math & Computat Sci, Tennent Dr, Palmerston North 4442, New Zealand
[7] AgResearch Ltd, Ethical Agr, 176 Puddle Alley, Mosgiel 9092, New Zealand
关键词
Absolute quantification; Digital PCR; Fecal indicator organisms; Naturalized Escherichia; Quantitation methods; Water microbial quality; GENETIC-STRUCTURE; QUANTITATIVE PCR; BACTERIA; STRAINS;
D O I
10.1016/j.mimet.2024.106909
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Escherichia coli are widely used by water quality managers as Fecal Indicator Bacteria, but current quantification methods do not differentiate them from benign, environmental Escherichia species such as E. marmotae (formerly named cryptic clade V) or E. ruysiae (cryptic clades III and IV). Reliable and specific techniques for their identification are required to avoid confounding microbial water quality assessments. To address this, a multiplex droplet digital PCR (ddPCR) assay targeting lipB (E. coli and E. ruysiae) and bglC (E. marmotae) was designed. The ddPCR performance was assessed using in silico analysis; genomic DNA from 40 local, international, and reference strains of target and non-target coliforms; and spiked water samples in a range relevant to water quality managers (1 to 1000 cells/100 mL). Results were compared to an analogous quantitative PCR (qPCR) and the Colilert method. Both PCR assays showed excellent sensitivity with a limit of detection of 0.05 pg/mu L and 0.005 pg/mu l for ddPCR and qPCR respectively, and of quantification of 0.5 pg/mu L of genomic DNA. The ddPCR allowed differentiation and quantification of three Escherichia species per run by amplitude multiplexing and showed a high concordance with concentrations measured by Colilert once proportional bias was accounted for. In silico specificity testing underlined the possibility to further detect and distinguish Escherichia cryptic clade VI. Finally, the applicability of the ddPCR was successfully tested on environmental water samples where E. marmotae and E. ruysiae potentially confound E. coli counts based on the Most Probable Number method, highlighting the utility of this novel ddPCR as an efficient and rapid discriminatory test to improve water quality assessments.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] The Clinical Significance of Enteropathogenic E. coli detected in Stool Multiplex PCR Assays
    Mowers, Jonathan
    Lamps, Laura W.
    Greenson, Joel
    Bachman, Michael
    MODERN PATHOLOGY, 2018, 31 : 290 - 290
  • [32] DipTest: A litmus test for E. coli detection in water
    Gunda, Naga Siva Kumar
    Dasgupta, Saumyadeb
    Mitra, Sushanta K.
    PLOS ONE, 2017, 12 (09):
  • [33] Detection of Shiga toxin-producing E. coli in environmental samples by immune-PCR
    He, Xiaohua
    Quinones, Baetriz
    McMahon, Stephanie
    Cooley, Michael
    Mandrell, Robert E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [34] Development and Application of a Multiplex Reverse Transcription-Droplet Digital PCR Assay for Simultaneous Detection of Hepatitis A Virus and Hepatitis E Virus in Bivalve Shellfish
    Wei, Maolin
    Wang, Jinfeng
    Wang, Yan
    Liu, Libing
    Xu, Xiangdong
    Wang, Jianchang
    FOODS, 2025, 14 (01)
  • [35] An Anti E. Coli O157:H7 Antibody-Immobilized Microcantilever for the Detection of Escherichia Coli (E. coli)
    Jing Zhang
    Hai-Feng Ji
    Analytical Sciences, 2004, 20 : 585 - 587
  • [36] Simultaneous detection of eight cancer types using a multiplex droplet digital PCR assay
    Neefs, Isabelle
    De Meulenaere, Nele
    Vanpoucke, Thomas
    Vandenhoeck, Janah
    Peeters, Dieter
    Peeters, Marc
    Van Camp, Guy
    Op de Beeck, Ken
    MOLECULAR ONCOLOGY, 2025, 19 (01) : 188 - 203
  • [37] Antimicrobial assay of shigatoxigenic E. coli (STEC) and enteropathogenic E. coli (EPEC) isolated from diarrhoeic faecal samples of piglets and infants in Mizoram
    Begum, Jubeda
    Dutta, Tapan Kumar
    Choudhary, Parimal Roy
    Chandra, Rajesh
    Varte, Zomuankima
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2015, 85 (10): : 7 - 12
  • [38] A single step multiplex PCR for identification of six diarrheagenic E. coli pathotypes and Salmonella
    Chandra, Mudit
    Cheng, Pui
    Rondeau, Gaelle
    Porwollik, Steffen
    McClelland, Michael
    INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2013, 303 (04) : 210 - 216
  • [39] Rapid detection of diarrheagenic E. coli by real-time PCR
    Bischoff, C
    Lüthy, J
    Altwegg, M
    Baggi, F
    JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 61 (03) : 335 - 341
  • [40] Duplex Droplet Digital PCR Assay for Quantification of Hepatitis E Virus in Food
    La Bella, Gianfranco
    Basanisi, Maria Grazia
    Nobili, Gaia
    D'Antuono, Anna Mattea
    Suffredini, Elisabetta
    La Salandra, Giovanna
    VIRUSES-BASEL, 2024, 16 (03):